Oscillometric and Doppler arterial blood pressure measurement in conscious goats

被引:0
|
作者
Szalus-Jordanow, Olga [1 ]
Czopowicz, Michal [2 ]
Swierk, Anna [4 ]
Szpinda, Oktawia [3 ]
Garncarz, Magdalena [3 ]
Mickiewicz, Marcin [2 ]
Moroz, Agata [2 ]
Bagnicka, Emilia [5 ]
Kaba, Jaroslaw [2 ]
机构
[1] Warsaw Univ Life Sci, Dept Small Anim Dis Clin, Fac Vet Med, Warsaw, Poland
[2] Warsaw Univ Life Sci, Lab Vet Epidemiol & Econ, Fac Vet Med, Warsaw, Poland
[3] Warsaw Univ Life Sci, Dept Pathol & Vet Diagnost, Fac Vet Med, Warsaw, Poland
[4] Round The Clock Vet Clin LEGWET, Legionowo, Poland
[5] Polish Acad Sci, Inst Genet & Anim Breeding, Magdalenka, Poland
关键词
SYSTEMIC HYPERTENSION; MONITOR; DOGS; IDENTIFICATION; AGREEMENT; ACCURACY;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The objective of this study was to characterize arterial blood pressure (BP) measurements obtained by using 2 indirect methods, oscillometry and Doppler ultrasonic sphygmomanometry, in conscious goats. Agreement between systolic BP yielded by these 2 methods was then assessed. Sixty female dairy goats aged from 1.5 to 11.8 y (median: 5.5 y) were examined in a standing position with a cuff placed on the tail. All goats had a severe arthritic form of caprine arthritis-encephalitis. Three to 5 repeated measurements of each BP type were averaged for each goat and considered as a final measurement. With oscillometry, systolic blood pressure (O-SBP), diastolic blood pressure, and mean blood pressure, as well as heart rate (HR) were measured, while only systolic blood pressure was measured with Doppler (D-SBP). The O-SBP did not correlate with D-SBP [correlation coefficient (r) = 0.24, P = 0.067]; the mean difference (+/- standard deviation) was 24.5 26.3 mmHg and limits of agreement were from -27.2 mmHg [95% confidence interval (CI): -39.0, -15.4 mmHg] to 76.1 mmHg (95% CI: 64.3, 87.9 mmHg). No significant linear correlation was found between any BPs and HR (r: 0.10 to 0.22) or age (r: 0.26 to 0.07) of the goats. The study showed that, while BP could be measured in conscious goats using both oscillometry and Doppler ultrasonic sphygmomanometry, the results obtained were so inconsistent that these methods could not be used interchangeably.
引用
收藏
页码:244 / 248
页数:5
相关论文
共 50 条
  • [1] Comparison of oscillometric, Doppler and invasive blood pressure measurement in anesthetized goats
    Szalus-Jordanow, Olga
    Czopowicz, Michel
    Moroz, Agata
    Mickiewicz, Marcin
    Garncarz, Magdalena
    Bagnicka, Emilia
    Frymus, Tadeusz
    Kaba, Jaroslaw
    [J]. PLOS ONE, 2018, 13 (05):
  • [2] OSCILLOMETRIC MEASUREMENT OF ARTERIAL BLOOD PRESSURE
    BENSON, H
    HERD, JA
    [J]. CIRCULATION, 1969, 40 (4S3) : II43 - &
  • [3] Agreement between the Petmap Oscillometric Device and Doppler Ultrasonic for Systolic Blood Pressure Measurement in Conscious Dogs
    Rezende Gloria, Ana Paula
    Monteiro, Eduardo Raposo
    Nunes Junior, Juarez Simoes
    Piccoli Rangel, Julia da Penha
    Campagnol, Daniela
    [J]. ACTA SCIENTIAE VETERINARIAE, 2015, 43
  • [4] Non-invasive blood pressure measurement in conscious rabbits: A comparison of Doppler ultrasonic and oscillometric devices
    Gonzalez-Gonzalez, Enrique
    Gonzalez-Alonso-Alegre, Elisa
    Montesinos-Barcelo, Andres
    Caro-Vadillo, Alicia
    [J]. VETERINARY RECORD, 2024,
  • [5] A comparison of CAT Doppler and oscillometric Memoprint machines for non-invasive blood pressure measurement in conscious cats
    Jepson, RE
    Hartley, V
    Mendl, M
    Caney, SM
    Gould, DJ
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2005, 7 (03) : 147 - 152
  • [6] DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT USING A CAROTID CATHETER IN COMPARISON TO OSCILLOMETRIC AND DOPPLER METHOD.
    Parker, K.
    Carr, A.
    Duke-Novakovski, T.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2012, 26 (03) : 710 - 711
  • [7] Comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in conscious dogs
    Bodey, AR
    Michell, AR
    Bovee, KC
    Buranakurl, C
    Garg, T
    [J]. RESEARCH IN VETERINARY SCIENCE, 1996, 61 (01) : 17 - 21
  • [8] Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs
    Haberman, Christopher E.
    Kang, Chang W.
    Morgan, Jefferson D.
    Brown, Scott A.
    [J]. CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2006, 70 (03): : 211 - 217
  • [9] Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs
    Vachon, Catherine
    Belanger, Marie C.
    Burns, Patrick M.
    [J]. RESEARCH IN VETERINARY SCIENCE, 2014, 97 (01) : 111 - 117
  • [10] Comparing Intra-Arterial, Auscultatory, and Oscillometric Measurement Methods for Arterial Blood Pressure
    Babadag, Keziban
    Zaybak, Ayten
    [J]. FLORENCE NIGHTINGALE JOURNAL OF NURSING, 2021, 29 (02): : 194 - 202