Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs

被引:0
|
作者
Haberman, Christopher E. [1 ]
Kang, Chang W. [1 ]
Morgan, Jefferson D. [1 ]
Brown, Scott A. [1 ]
机构
[1] Univ Georgia, Coll Vet Med, Dept Physiol & Pharmacol, Athens, GA 30602 USA
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
To assess the accuracy and precision of indirect measurements of systemic arterial blood pressure (BP), results obtained with an oscillometric device (BPo) and a Doppler ultrasonic device (BPud) were compared with those obtained by direct radiotelemetry (BPrt) in 12 conscious beagles. The correlation between indirectly obtained and directly measured values for BP parameters ranged widely for the different indirect methods and sites of cuff placement, with R-2 between 0.001 and 0.901. Both indirect methods underestimated all BP parameters, the degree of underestimation increasing at higher values for the BP. The highest correlation occurred when estimates were the average of 5 values consecutively obtained with the oscillometric device and cuff placement at the coccygeal artery (R-2 = 0.854 for mean BPo, 0.886 for systolic BPo, and 0.901 for diastolic BPo; P < 0.0001 for all parameters) or with the ultrasonic Doppler device at the metatarsal arteries (R-2 = 0.810 for systolic BPud; P < 0.0001). Multiple consecutively obtained values are advised, as this approach improves the reliability of indirect BP measurements. The strong correlation between directly measured values and estimates derived as the average of 5 consecutive indirectly obtained values indicates that the latter approach provides a useful estimate of BP in conscious dogs and is likely to be useful in monitoring disease progress and treatment in dogs with abnormal BP.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 50 条
  • [1] Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs
    Vachon, Catherine
    Belanger, Marie C.
    Burns, Patrick M.
    [J]. RESEARCH IN VETERINARY SCIENCE, 2014, 97 (01) : 111 - 117
  • [2] Agreement between the Petmap Oscillometric Device and Doppler Ultrasonic for Systolic Blood Pressure Measurement in Conscious Dogs
    Rezende Gloria, Ana Paula
    Monteiro, Eduardo Raposo
    Nunes Junior, Juarez Simoes
    Piccoli Rangel, Julia da Penha
    Campagnol, Daniela
    [J]. ACTA SCIENTIAE VETERINARIAE, 2015, 43
  • [3] Comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in conscious dogs
    Bodey, AR
    Michell, AR
    Bovee, KC
    Buranakurl, C
    Garg, T
    [J]. RESEARCH IN VETERINARY SCIENCE, 1996, 61 (01) : 17 - 21
  • [4] Systemic blood pressure evaluation by oscillometric versus doppler ultrasonographic methods in obese dogs
    Pereira-Neto, Glucia B.
    Brunetto, Marcio A.
    Champion, Tatiana
    Ortiz, Edna M. G.
    Carciofi, Aulus C.
    Camacho, Aparecido A.
    [J]. PESQUISA VETERINARIA BRASILEIRA, 2014, 34 : 87 - 91
  • [5] Indirect blood pressure determination in cats using Doppler ultrasonic and oscillometric method
    Möllenhoff, A
    Nolte, I
    Kramer, S
    [J]. TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2001, 29 (03): : 191 - 197
  • [6] INDIRECT BLOOD-PRESSURE DETERMINATION BY ULTRASONIC DOPPLER TECHNIQUE IN DOGS
    FREUNDLICH, JJ
    DETWEILER, DK
    HANCE, HE
    [J]. CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 1972, 14 (02): : 73 - +
  • [7] Evaluation of an indirect oscillometric blood pressure monitor in normotensive and hypotensive anesthetized dogs
    Shih, Andre
    Robertson, Sheilah
    Vigani, Alessio
    da Cunha, Anderson
    Pablo, Luisito
    Bandt, Carsten
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2010, 20 (03) : 313 - 318
  • [8] Oscillometric and Doppler arterial blood pressure measurement in conscious goats
    Szalus-Jordanow, Olga
    Czopowicz, Michal
    Swierk, Anna
    Szpinda, Oktawia
    Garncarz, Magdalena
    Mickiewicz, Marcin
    Moroz, Agata
    Bagnicka, Emilia
    Kaba, Jaroslaw
    [J]. CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2018, 82 (04): : 244 - 248
  • [9] Comparison of the indirect oscillometric and direct arterial methods for blood pressure measurements in anesthetized dogs
    Meurs, KM
    Miller, MW
    Slater, MR
    [J]. JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1996, 32 (06) : 471 - 475
  • [10] Non-invasive blood pressure measurement in conscious rabbits: A comparison of Doppler ultrasonic and oscillometric devices
    Gonzalez-Gonzalez, Enrique
    Gonzalez-Alonso-Alegre, Elisa
    Montesinos-Barcelo, Andres
    Caro-Vadillo, Alicia
    [J]. VETERINARY RECORD, 2024,