Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs

被引:54
|
作者
Vachon, Catherine [1 ]
Belanger, Marie C. [1 ]
Burns, Patrick M. [1 ]
机构
[1] Univ Montreal, Dept Clin Sci, Fac Med Vet, Montreal, PQ H3C 3J7, Canada
关键词
Blood pressure measurement; Doppler; Oscillometry; petMAP (R); Dogs; Conscious; Anesthetized; ARTERIAL-PRESSURE; HIGH-DEFINITION; MONITOR; HYPERTENSION; ACCURACY; GUIDELINES; AGREEMENT; FLOW;
D O I
10.1016/j.rvsc.2014.05.003
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Two non-invasive blood pressure (NIBP) devices (oscillometry and Doppler) were compared to invasive blood pressure using a Bland-Altman analysis, in anesthetized and conscious dogs. When considering the systolic arterial pressure only during general anesthesia, both NIBP devices slightly underestimated the systolic arterial blood pressure however the precision and the limits of agreement for the Doppler were of a greater magnitude. This indicates a worse clinical performance by the Doppler. The performance of both NIBP devices deteriorated as measured in conscious animals. In general, for the oscillometric device, determination of invasive diastolic and mean arterial pressures was better than the invasive systolic arterial pressure. Overall, the oscillometric device satisfied more of the criteria set by the American College of Veterinary Internal Medicine consensus statement. Based upon these results, the oscillometric device is more reliable than the Doppler in the determination of blood pressure in healthy medium to large breed dogs. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 50 条
  • [1] Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs
    Haberman, Christopher E.
    Kang, Chang W.
    Morgan, Jefferson D.
    Brown, Scott A.
    [J]. CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2006, 70 (03): : 211 - 217
  • [2] Agreement between the Petmap Oscillometric Device and Doppler Ultrasonic for Systolic Blood Pressure Measurement in Conscious Dogs
    Rezende Gloria, Ana Paula
    Monteiro, Eduardo Raposo
    Nunes Junior, Juarez Simoes
    Piccoli Rangel, Julia da Penha
    Campagnol, Daniela
    [J]. ACTA SCIENTIAE VETERINARIAE, 2015, 43
  • [3] Non-invasive blood pressure measurement in conscious rabbits: A comparison of Doppler ultrasonic and oscillometric devices
    Gonzalez-Gonzalez, Enrique
    Gonzalez-Alonso-Alegre, Elisa
    Montesinos-Barcelo, Andres
    Caro-Vadillo, Alicia
    [J]. VETERINARY RECORD, 2024,
  • [4] Indirect oscillometric and direct blood pressure measurements in anesthetized and conscious neonatal foals
    Nout, YS
    Corley, KTT
    Donaldson, LL
    Furr, MO
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2002, 12 (02): : 75 - 80
  • [5] Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs
    Bosiack, Ann P.
    Mann, F. A.
    Dodam, John R.
    Wagner-Mann, Colette C.
    Branson, Keith R.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2010, 20 (02) : 207 - 215
  • [6] Comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in conscious dogs
    Bodey, AR
    Michell, AR
    Bovee, KC
    Buranakurl, C
    Garg, T
    [J]. RESEARCH IN VETERINARY SCIENCE, 1996, 61 (01) : 17 - 21
  • [7] Evaluation of an oscillometric blood pressure monitor in anesthetized dogs: Agreement with direct measurements and ability to detect hypotension
    Sedgwick, Samantha
    Lorenzutti, Augusto M.
    Araos, Joaquin B.
    Gleed, Robin D.
    Martin-Flores, Manuel
    [J]. RESEARCH IN VETERINARY SCIENCE, 2021, 135 : 162 - 166
  • [8] Evaluation of an indirect oscillometric blood pressure monitor in normotensive and hypotensive anesthetized dogs
    Shih, Andre
    Robertson, Sheilah
    Vigani, Alessio
    da Cunha, Anderson
    Pablo, Luisito
    Bandt, Carsten
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2010, 20 (03) : 313 - 318
  • [9] Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs
    Sawyer, DC
    Guikema, AH
    Siegel, EM
    [J]. VETERINARY ANAESTHESIA AND ANALGESIA, 2004, 31 (01) : 27 - 39
  • [10] Comparison of the indirect oscillometric and direct arterial methods for blood pressure measurements in anesthetized dogs
    Meurs, KM
    Miller, MW
    Slater, MR