A comparison of CAT Doppler and oscillometric Memoprint machines for non-invasive blood pressure measurement in conscious cats

被引:42
|
作者
Jepson, RE [1 ]
Hartley, V [1 ]
Mendl, M [1 ]
Caney, SM [1 ]
Gould, DJ [1 ]
机构
[1] Univ Bristol, Dept Clin Vet Med, Bristol BS40 5DU, Avon, England
关键词
D O I
10.1016/j.jfms.2004.08.003
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Indirect blood pressure measurements were compared in 28 conscious cats using Doppler and oscillometric blood pressure-measuring devices. Ten cats were used to compare Doppler measurements between two examiners and 18 cats were used to compare Doppler and oscillometric measurements. The Doppler machine obtained systolic and diastolic blood pressure readings in 100% and 51% of attempts, respectively. With the oscillometric machine, systolic and diastolic blood pressure readings were obtained in 52% of the attempts. With the Doppler, measures of mean systolic blood pressure between two examiners were positively correlated, but there was no correlation for diastolic blood pressure measures. When comparing the results obtained by Doppler and oscillometric machines there was no significant difference between mean systolic blood pressure readings, but the oscillometric machine produced significantly higher estimates of diastolic blood pressure. In both cases, the standard deviations for the oscillometric machine were considerably larger than those for the Doppler machine. The first reading of systolic blood pressure obtained with the Doppler machine was an excellent predictor of the mean of five readings, but this was not so for the oscillometric machine. It took less than 5 min to obtain five readings in 37.5% of cases with the Doppler machine but this was true for only 5% of cases with the oscillometric machine. Two cats with ophthalmological lesions consistent with systemic hypertension were identified. In these two patients, systolic blood pressure measurements were between 200 and 225 mmHg when measured by Doppler, and between 140 and 150 mmHg when measured by the oscillometric machine. This suggests that a lower reference range for normal systolic blood pressure values should be used for the oscillometric device. (c) 2004 ESFM and AAFP. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:147 / 152
页数:6
相关论文
共 50 条
  • [1] Comparison of Thames Medical CAT plus Doppler and SunTech Vet 20 oscillometric devices for non-invasive blood pressure measurement in conscious cats
    Casas, Clara
    Dye, Charlotte
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2024, 26 (02)
  • [2] Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats
    Cerna, Petra
    Archontakis, Panos E.
    Cheuk, Hester O. K.
    Gunn-Moore, Danielle A.
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2021, 23 (02) : 121 - 130
  • [3] Non-invasive blood pressure measurement in conscious rabbits: A comparison of Doppler ultrasonic and oscillometric devices
    Gonzalez-Gonzalez, Enrique
    Gonzalez-Alonso-Alegre, Elisa
    Montesinos-Barcelo, Andres
    Caro-Vadillo, Alicia
    VETERINARY RECORD, 2024, 195 (07)
  • [4] A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis
    Jiang, Ziqing
    Li, Shaoying
    Wang, Lin
    Yu, Feng
    Zeng, Yanping
    Li, Hongbo
    Li, Jun
    Zhang, Zhanfeng
    Zuo, Junling
    JOURNAL OF ANESTHESIA, 2024, 38 (02) : 222 - 231
  • [5] A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis
    Ziqing Jiang
    Shaoying Li
    Lin Wang
    Feng Yu
    Yanping Zeng
    Hongbo Li
    Jun Li
    Zhanfeng Zhang
    Junling Zuo
    Journal of Anesthesia, 2024, 38 : 222 - 231
  • [6] Comparison of Doppler ultrasonic sphygmomanometry, oscillometry and high-definition oscillometry for non-invasive blood pressure measurement in conscious cats
    Knies, Marieke
    Teske, Erik
    Kooistra, Hans
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2024, 26 (03)
  • [7] Comparison of oscillometric, Doppler and invasive blood pressure measurement in anesthetized goats
    Szalus-Jordanow, Olga
    Czopowicz, Michel
    Moroz, Agata
    Mickiewicz, Marcin
    Garncarz, Magdalena
    Bagnicka, Emilia
    Frymus, Tadeusz
    Kaba, Jaroslaw
    PLOS ONE, 2018, 13 (05):
  • [8] A clinical evaluation of blood pressure through non-invasive measurement using the oscillometric procedure in conscious dogs
    Mishina, M
    Watanabe, T
    Fujii, K
    Maeda, H
    Wakao, Y
    Takahashi, M
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1997, 59 (11): : 989 - 993
  • [9] Non-invasive blood pressure measurement in dogs and cats
    Mandigers, P
    TIJDSCHRIFT VOOR DIERGENEESKUNDE, 2005, 130 (07) : 198 - 201
  • [10] Oscillometric and Doppler arterial blood pressure measurement in conscious goats
    Szalus-Jordanow, Olga
    Czopowicz, Michal
    Swierk, Anna
    Szpinda, Oktawia
    Garncarz, Magdalena
    Mickiewicz, Marcin
    Moroz, Agata
    Bagnicka, Emilia
    Kaba, Jaroslaw
    CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2018, 82 (04): : 244 - 248