Development of a new oscillometric blood pressure measurement system

被引:17
|
作者
Moraes, JCTB [1 ]
Cerulli, M [1 ]
Ng, PS [1 ]
机构
[1] Univ Sao Paulo, Escola Politecn, Sao Paulo, Brazil
来源
关键词
D O I
10.1109/CIC.1999.826009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new blood pressure measurement system was developed based on the oscillometric method using a controlled linear deflation technique. The system was structured in order to make several tasks independent and specialized, thus allowing for future punctual developments. An oscillometric signal data base was formed according to the standard ANSI/AAMI/SP10-1992, using the manual auscultatory method as a reference to determine measurement techniques to be used. The correlation among several quantities such as reference blood pressure measurements, characteristic ratios age, weight, height and arm circumference size, was studied. A new strategy to obtain systolic mean and diastolic pressures was oscillometric pulse envelope, depending on parameters such as actual cuff pressure, mean pressure, pulse amplitude and arm circumference size. Mean differences of about -1,49 and 0,61 and standard deviations of 5,11 and 5,89 mmHg were obtained for systolic and diastolic pressure measurements, respectively. Moreover a comparative study with a commercial equipment was performed, with a simulator.
引用
收藏
页码:467 / 470
页数:4
相关论文
共 50 条
  • [41] Development of a Cuffless Blood Pressure Measurement System
    Shyu, Liang-Yu
    Kao, Yao-Lin
    Tsai, Wen-Ya
    Hu, Weichih
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2040 - 2043
  • [42] System for a Blood Pressure Measurement Algorithm Development
    Yoo, J. Y.
    Park, S. M.
    Ye, S. Y.
    Jeon, G. R.
    PROCEEDINGS OF THE 8TH WSEAS INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE, MAN-MACHINE SYSTEMS AND CYBERNETICS (CIMMACS '09), 2009, : 104 - +
  • [43] Evaluation of a new oscillometric blood pressure monitor with a triggered measurement mode engaged with hemodynamic changes
    Kumagai, K
    Komatsu, T
    Yokota, S
    Nishiwaki, K
    Shimada, Y
    ANESTHESIOLOGY, 1997, 87 (03) : A425 - A425
  • [44] Automatic blood pressure measurement: the oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    JOURNAL OF HYPERTENSION, 2008, 26 (01) : 35 - 43
  • [45] A new system for cuffless blood pressure measurement
    Ankishan, H.
    Ari, Fikret
    Celik, Haydar
    Frederick, Blaise B.
    Hocke, Lia M.
    Erdogan, Sinem Burcu
    Unal, Mehmet Altay
    APPLIED ACOUSTICS, 2023, 212
  • [46] A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis
    Jiang, Ziqing
    Li, Shaoying
    Wang, Lin
    Yu, Feng
    Zeng, Yanping
    Li, Hongbo
    Li, Jun
    Zhang, Zhanfeng
    Zuo, Junling
    JOURNAL OF ANESTHESIA, 2024, 38 (02) : 222 - 231
  • [47] A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis
    Ziqing Jiang
    Shaoying Li
    Lin Wang
    Feng Yu
    Yanping Zeng
    Hongbo Li
    Jun Li
    Zhanfeng Zhang
    Junling Zuo
    Journal of Anesthesia, 2024, 38 : 222 - 231
  • [48] An Initial Step Towards Improving the Accuracy of the Oscillometric Blood Pressure Measurement
    Liu, Jiankun
    Hahn, Jin-Oh
    Mukkamala, Ramakrishna
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 4082 - 4085
  • [49] ACCURACY OF OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT IN CRITICALLY ILL NEONATES
    GEVERS, M
    VANGENDERINGEN, HR
    LAFEBER, HN
    HACK, WW
    PEDIATRIC RESEARCH, 1994, 36 (01) : A15 - A15
  • [50] Accuracy of oscillometric blood pressure measurement at both arms in the lateral position
    Mostafa, Maha
    Hasanin, Ahmed M.
    Elsayed, Omnia S.
    Mostafa, Mamdouh M.
    Sarhan, Khaled
    BLOOD PRESSURE MONITORING, 2021, 26 (05) : 364 - 372