Variable air volume system application in museums

被引:0
|
作者
Wang, Zhan [1 ]
Bin Zheng [1 ]
Xu, Wenlong [1 ]
Wang, Gang [1 ]
Liu, Mingsheng [1 ]
机构
[1] Univ Nebraska, Dept Architectural Engn, Lincoln, NE 68583 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Relative humidity and temperature control is key in museums, galleries, libraries and archives. Normally constant volume (CV) air handling units (AHUs) with reheat coils are applied in these buildings. Setting a low supply air temperature limits the highest humidity level; however, reheat coils have to be used to maintain space temperature due to constant supply airflow. As a result, simultaneous heating and cooling exists with excessive energy consumption. It is well known that variable air volume (VAV) technologies can reduce simultaneous heating and cooling as well as fan power. This paper presents the detail VAV system retrofit for the existing CV system, control sequence development and system performance evaluation in a museum facility at Omaha, Nebraska. Variable Frequency Drives (VFDs) were installed for the supply fan on the AHUs. Space humidity and temperature, heating and cooling energy consumption, and fan power were measured. The measurements showed that the space humidity and temperature was maintained within the required range under VAV operation while the reheat consumption was reduced by up to 85% and the fan power consumption was reduced by 90% under partial cooling loads.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [41] Displacement ventilation and Variable Air Volume (VAV) system in a historical museum
    Schellen, Henk
    van Aarle, Marcel
    Neuhaus, Edgar
    Pernot, Cor
    RESEARCH ON BUILDING PHYSICS, 2010, : 519 - 526
  • [42] Coordinated optimization of the variable refrigerant flow and variable air volume combined air-conditioning system in heating conditions
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    He, Chao
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 904 - 916
  • [43] Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fang, Xing
    APPLIED THERMAL ENGINEERING, 2015, 80 : 87 - 96
  • [44] Direct Feedback Linearization Based Control in Variable Air Volume air-conditioning System
    Shi, Zhigang
    Li, Xuquan
    Hu, Songtao
    2010 INTERNATIONAL COLLOQUIUM ON COMPUTING, COMMUNICATION, CONTROL, AND MANAGEMENT (CCCM2010), VOL III, 2010, : 248 - 251
  • [45] Direct Feedback Linearization Based Control in Variable Air Volume air-conditioning System
    Shi, Zhigang
    Li, Xuquan
    Hu, Songtao
    INTERNATIONAL CONFERENCE ON APPLIED PHYSICS AND INDUSTRIAL ENGINEERING 2012, PT B, 2012, 24 : 1248 - 1254
  • [46] Modeling and simulation of variable air volume air-conditioning system and its control strategy
    Zhao, Zhe Shen
    Wu, Ye
    Lue, Jibin
    PROCEEDINGS OF THE 16TH IASTED INTERNATIONAL CONFERENCE ON APPLIED SIMULATION AND MODELLING, 2007, : 376 - 381
  • [47] Analysis of Indoor Inhalable Particle Concentration under Variable Air Volume Air Conditioning System
    Li, Xin-long
    Huang, Yue-wu
    PROCEEDINGS OF THE 2ND 2016 INTERNATIONAL CONFERENCE ON SUSTAINABLE DEVELOPMENT (ICSD 2016), 2017, 94 : 286 - 289
  • [48] Analytical Design of Decoupling Control for Variable-Air-Volume Air-conditioning System
    Wang, Jiangjiang
    Zhang, Chunfa
    Jing, Youyin
    2008 IEEE CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS, VOLS 1 AND 2, 2008, : 535 - 540
  • [49] Feedback linearization based control of a variable air volume air conditioning system for cooling applications
    Thosar, Archana
    Patra, Amit
    Bhattacharyya, Souvik
    ISA TRANSACTIONS, 2008, 47 (03) : 339 - 349
  • [50] Indoor air quality and the variable-air-volume bypass filtration system: Chamber experiment
    Moschandreas, DJ
    Choi, SW
    Meckler, MM
    ENVIRONMENT INTERNATIONAL, 1996, 22 (02) : 149 - 158