Analytical Design of Decoupling Control for Variable-Air-Volume Air-conditioning System

被引:0
|
作者
Wang, Jiangjiang [1 ]
Zhang, Chunfa [1 ]
Jing, Youyin [1 ]
机构
[1] N China Elect Power Univ, Sch Energy & Power Engn, Baoding 071003, Hebei Province, Peoples R China
关键词
variable-air-volume (VAV) system; air-conditioning system; decoupling control; internal model control;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Variable-air-volume (VAV) air-conditioning system has the feature of multi-variable, intense coupling and nonlinear. The coupling may directly affect the property and the stability of VAV system. In this paper, a theoretical model of VAV air-conditioning system by combining the theoretical analysis with the data analysis of experiment is established, which is the four input-output transfer function matrix. Based on the model, a new analytical design method of decoupling controller matrix is proposed in terms of the standard internal model control structure for VAV air-conditioning system. Its advantage is that absolute decoupling for the nominal responses of system outputs can be implemented, and moreover, the controller parameters can be tuned on-line in a monotonous manner to cope with the plant unmodelled dynamics, so that significant decoupling regulation can be achieved. The simulation curves of the decoupling control system show the availability of the method.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 50 条
  • [1] Decoupling Control of a Variable-Air-Volume Air-Conditioning System Based on State Feedback
    Huang, Yonghong
    Yang, Xuejun
    [J]. 2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL III, PROCEEDINGS, 2008, : 589 - +
  • [2] VARIABLE-AIR-VOLUME AIR-CONDITIONING
    NASENBENY, RJ
    [J]. SPECIFYING ENGINEER, 1985, 53 (06): : 117 - 119
  • [3] Intelligent decoupling and coordinating control in Variable-Air-Volume air conditioning system
    Liu, Guanghui
    Meng, Yuebo
    Wang, Hongding
    [J]. 2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 3, 2008, : 461 - 465
  • [4] Variable-air-volume air-conditioning system under reduced static pressure control
    Dah Chong Hong Ltd, Kowloon, Hong Kong
    [J]. Build Serv Eng Res Technol, 2 (77-83):
  • [5] Discussion on the Application of Variable-air-volume Air-conditioning System on Ships
    Guo, Junjie
    Chen, Wu
    Cai, Zhenxiong
    Zheng, Chaoyu
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 413 - 418
  • [6] Optimal control of variable air volume air-conditioning system
    Chen, You-Ming
    Liu, Jian
    Cheng, Shi-Bai
    Chan, Wing-Hong
    Qin, Jian-Ying
    Zhou, Qiang
    [J]. Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2013, 40 (06): : 1 - 6
  • [7] A MEMS flow sensor applied in a variable-air-volume unit in a building air-conditioning system
    Shikida, M.
    Yamazaki, Y.
    Yoshikawa, K.
    Sato, Kazuo
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2013, 189 : 212 - 217
  • [8] Space temperature control of variable air volume air-conditioning system
    Gao, Jiajia
    Xu, Xinhua
    Huang, Gongsheng
    [J]. Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2015, 43 (12): : 86 - 89
  • [9] Life-cycle cost analysis for constant-air-volume and variable-air-volume air-conditioning systems
    Aktacir, MA
    Büyükalaca, O
    Yilmaz, T
    [J]. APPLIED ENERGY, 2006, 83 (06) : 606 - 627
  • [10] Optimization of Double-Closed-Loop Control of Variable-Air-Volume Air-Conditioning System Based on Dynamic Response Model
    Li, Duanzheng
    Ahmat, Mutellip
    Cao, Hongqing
    Di, Fankai
    [J]. BUILDINGS, 2024, 14 (03)