Optimization of Double-Closed-Loop Control of Variable-Air-Volume Air-Conditioning System Based on Dynamic Response Model

被引:1
|
作者
Li, Duanzheng [1 ]
Ahmat, Mutellip [1 ]
Cao, Hongqing [2 ]
Di, Fankai [1 ]
机构
[1] Xinjiang Univ, Coll Elect Engn, Urumqi 830047, Peoples R China
[2] Xinjiang Special Equipment Inspect & Res Inst, Urumqi 830011, Peoples R China
关键词
VAV; end air valve; air supply fan; dynamic response model; fuzzy PI; TERMINAL UNIT; IDENTIFICATION;
D O I
10.3390/buildings14030677
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Control strategies for variable-air-volume (VAV) air conditioning significantly affect both the air quality within buildings and the consumption of building energy. Current control techniques effectively regulate room temperature using feedback on temperature discrepancies, yet they also elevate the wear on terminal devices and boost the energy usage of the supply fan. In this paper, the hysteresis and inertia parameters of end air valves and supply fans under two seasonal conditions are derived from experimental data. Aiming at the problems of frequent switching of the end air valve, long total switching stroke, and high energy consumption of the air supply fan, a fuzzy PI regulation method is proposed based on the original pressure-independent series PI regulation, which effectively solves the above problems. Initially, data on how room temperature reacts to changes in air supply fan speed and the position of end air valves during winter and summer were gathered. Following model identification, parameters for various seasonal conditions were determined. Secondly, the roles of different components in the variable-air-volume regulation process were investigated. Investigations revealed that within pressure-independent variable-air-volume control, the supply fan and end air valve emerged as the primary subjects of the study. A double-closed-loop control with the speed control of the supply fan as the outer loop and the opening control of the end air valve as the inner loop was adopted. Compared with the traditional serial PI regulation, the room temperature error of this method was increased, but it reduced the total stroke of the valve by more than 43%, which greatly reduced the valve's loss and noise and saved more than 2.7% of the energy consumption of the air supply fan.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] VARIABLE-AIR-VOLUME AIR-CONDITIONING
    NASENBENY, RJ
    [J]. SPECIFYING ENGINEER, 1985, 53 (06): : 117 - 119
  • [2] Decoupling Control of a Variable-Air-Volume Air-Conditioning System Based on State Feedback
    Huang, Yonghong
    Yang, Xuejun
    [J]. 2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL III, PROCEEDINGS, 2008, : 589 - +
  • [3] Analytical Design of Decoupling Control for Variable-Air-Volume Air-conditioning System
    Wang, Jiangjiang
    Zhang, Chunfa
    Jing, Youyin
    [J]. 2008 IEEE CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS, VOLS 1 AND 2, 2008, : 535 - 540
  • [4] Discussion on the Application of Variable-air-volume Air-conditioning System on Ships
    Guo, Junjie
    Chen, Wu
    Cai, Zhenxiong
    Zheng, Chaoyu
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 413 - 418
  • [5] Dynamic performance of an electronic zone air temperature control loop in a typical variable-air-volume air conditioning system
    Hung, CYS
    Lam, HN
    Dunn, A
    [J]. HVAC&R RESEARCH, 1999, 5 (04): : 317 - 337
  • [6] Intelligent decoupling and coordinating control in Variable-Air-Volume air conditioning system
    Liu, Guanghui
    Meng, Yuebo
    Wang, Hongding
    [J]. 2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 3, 2008, : 461 - 465
  • [7] A MEMS flow sensor applied in a variable-air-volume unit in a building air-conditioning system
    Shikida, M.
    Yamazaki, Y.
    Yoshikawa, K.
    Sato, Kazuo
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2013, 189 : 212 - 217
  • [8] Direct Feedback Linearization Based Control in Variable Air Volume air-conditioning System
    Shi, Zhigang
    Li, Xuquan
    Hu, Songtao
    [J]. 2010 INTERNATIONAL COLLOQUIUM ON COMPUTING, COMMUNICATION, CONTROL, AND MANAGEMENT (CCCM2010), VOL III, 2010, : 248 - 251
  • [9] Direct Feedback Linearization Based Control in Variable Air Volume air-conditioning System
    Shi, Zhigang
    Li, Xuquan
    Hu, Songtao
    [J]. INTERNATIONAL CONFERENCE ON APPLIED PHYSICS AND INDUSTRIAL ENGINEERING 2012, PT B, 2012, 24 : 1248 - 1254
  • [10] Life-cycle cost analysis for constant-air-volume and variable-air-volume air-conditioning systems
    Aktacir, MA
    Büyükalaca, O
    Yilmaz, T
    [J]. APPLIED ENERGY, 2006, 83 (06) : 606 - 627