Variable air volume system application in museums

被引:0
|
作者
Wang, Zhan [1 ]
Bin Zheng [1 ]
Xu, Wenlong [1 ]
Wang, Gang [1 ]
Liu, Mingsheng [1 ]
机构
[1] Univ Nebraska, Dept Architectural Engn, Lincoln, NE 68583 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Relative humidity and temperature control is key in museums, galleries, libraries and archives. Normally constant volume (CV) air handling units (AHUs) with reheat coils are applied in these buildings. Setting a low supply air temperature limits the highest humidity level; however, reheat coils have to be used to maintain space temperature due to constant supply airflow. As a result, simultaneous heating and cooling exists with excessive energy consumption. It is well known that variable air volume (VAV) technologies can reduce simultaneous heating and cooling as well as fan power. This paper presents the detail VAV system retrofit for the existing CV system, control sequence development and system performance evaluation in a museum facility at Omaha, Nebraska. Variable Frequency Drives (VFDs) were installed for the supply fan on the AHUs. Space humidity and temperature, heating and cooling energy consumption, and fan power were measured. The measurements showed that the space humidity and temperature was maintained within the required range under VAV operation while the reheat consumption was reduced by up to 85% and the fan power consumption was reduced by 90% under partial cooling loads.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [21] How to Design a Variable Air Volume Central Hospital Air Handling System
    English, Travis R.
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 439 - 447
  • [22] Space temperature control of variable air volume air-conditioning system
    Gao, Jiajia
    Xu, Xinhua
    Huang, Gongsheng
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2015, 43 (12): : 86 - 89
  • [23] Application of Artificial Neural Network Based on Nonlinear Predictive Optimal Control in Variable Air Volume System
    Liu Jing-wan
    Wei Dong
    Li Rui
    2008 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-11, 2008, : 3058 - +
  • [24] Simulation of Variable Air Volume System with Different Duct Layout
    陈华
    涂光备
    FRANCIS W H Yika
    Transactions of Tianjin University, 2004, (01) : 24 - 28
  • [25] Optimization of thermal processes in a variable air volume HVAC system
    Zheng, GR
    ZaheerUddin, M
    ENERGY, 1996, 21 (05) : 407 - 420
  • [26] VARIABLE AIR VOLUME SYSTEM CONTROLS: PROBLEMS AND SOLUTIONS.
    Milewski, Les
    1600, (49):
  • [27] DDC: VARIABLE AIR VOLUME APPLICATION DEMONSTRATES KEY ADVANTAGE.
    Walker, Charles A.
    ASHRAE Journal, 1984, 26 (09) : 23 - 27
  • [28] VARIABLE AIR VOLUME DESIGN
    LANGBEIN, CE
    BUILDING SYSTEMS DESIGN, 1978, 75 (04): : 30 - 36
  • [29] Optimal control of combined air conditioning system with variable refrigerant flow and variable air volume for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Fang, Xing
    Du, Zhimin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 42 : 14 - 25
  • [30] Simulation design of automatic control system of variable air volume air conditioning under simple air volume control algorithm
    Hu Nan Financial & Industry Vocational-Technical College, Hu Nan
    421000, China
    不详
    不详
    Int. J. Mech. Appl. Mech., 2020, 8 (70-76):