Variable air volume system application in museums

被引:0
|
作者
Wang, Zhan [1 ]
Bin Zheng [1 ]
Xu, Wenlong [1 ]
Wang, Gang [1 ]
Liu, Mingsheng [1 ]
机构
[1] Univ Nebraska, Dept Architectural Engn, Lincoln, NE 68583 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Relative humidity and temperature control is key in museums, galleries, libraries and archives. Normally constant volume (CV) air handling units (AHUs) with reheat coils are applied in these buildings. Setting a low supply air temperature limits the highest humidity level; however, reheat coils have to be used to maintain space temperature due to constant supply airflow. As a result, simultaneous heating and cooling exists with excessive energy consumption. It is well known that variable air volume (VAV) technologies can reduce simultaneous heating and cooling as well as fan power. This paper presents the detail VAV system retrofit for the existing CV system, control sequence development and system performance evaluation in a museum facility at Omaha, Nebraska. Variable Frequency Drives (VFDs) were installed for the supply fan on the AHUs. Space humidity and temperature, heating and cooling energy consumption, and fan power were measured. The measurements showed that the space humidity and temperature was maintained within the required range under VAV operation while the reheat consumption was reduced by up to 85% and the fan power consumption was reduced by 90% under partial cooling loads.
引用
下载
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [31] A review of Static Pressure Reset Control in Variable Air Volume Air Condition System
    Zhang, Jili
    Li, Xiuming
    Zhao, Tianyi
    Yu, Hao
    Chen, Tingting
    Liu, Chao
    Yang, Xinwei
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1844 - 1850
  • [32] Numerical research on the operation characteristics of marine variable air volume air conditioning system
    Zhao, Zhongchao
    Zhang, Jiaojiao
    Cheng, Hua
    Shen, Rendong
    ADVANCES IN BUILDING ENERGY RESEARCH, 2018, 12 (02) : 235 - 249
  • [33] Research on a hierarchical air balancing control method of variable air volume ventilation system
    Cai, Hui
    Cui, Can
    Zhang, Xin
    Cai, Wenjian
    Dai, Jinyang
    BUILDING AND ENVIRONMENT, 2020, 175
  • [34] Intelligent decoupling and coordinating control in Variable-Air-Volume air conditioning system
    Liu, Guanghui
    Meng, Yuebo
    Wang, Hongding
    2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 3, 2008, : 461 - 465
  • [35] Optimal supply air temperature with respect to energy use in a variable air volume system
    Engdahl, F
    Johansson, D
    ENERGY AND BUILDINGS, 2004, 36 (03) : 205 - 218
  • [36] Control strategy of variable air volume air conditioning system under intelligent algorithm
    Liu, Ning (ningliuningliuzz@yeah.net), 1600, Editura Politechnica (18):
  • [37] Application of Residual-Based EWMA Control Charts for Detecting Faults in Variable-Air-Volume Air Handling Unit System
    Wang, Haitao
    JOURNAL OF CONTROL SCIENCE AND ENGINEERING, 2016, 2016
  • [38] VARIABLE AIR VOLUME SYSTEMS ... TYPES, MODULATION, AND SELECTION OF SYSTEM FANS
    PATTERSON, NR
    PLANT ENGINEERING, 1980, 34 (03) : 67 - 70
  • [39] Optimal Control Method of Variable Air Volume Terminal Unit System
    Kim, Hyo-Jun
    Cho, Young-Hum
    ENERGIES, 2021, 14 (22)
  • [40] A critical evaluation of variable air volume system in hot and humid climates
    Sekhar, SC
    ENERGY AND BUILDINGS, 1997, 26 (02) : 223 - 232