Risk of stroke early after implantation of a left ventricular assist device

被引:10
|
作者
Samura, Takaaki [1 ]
Yoshioka, Daisuke [1 ]
Toda, Koichi [1 ]
Sakaniwa, Ryoto [2 ]
Shimizu, Mikito [3 ]
Miyagawa, Shigeru [1 ]
Yoshikawa, Yasushi [1 ]
Hata, Hiroki [1 ]
Saito, Shunsuke [1 ]
Sakata, Yasushi [4 ]
Sawa, Yoshiki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Yamadaoka 2-2, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Publ Hlth, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Neurol, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Cardiol, Osaka, Japan
来源
关键词
left ventricular assist device; low cardiac output; pump thrombosis; stroke; HEART MATE II; INTERAGENCY REGISTRY; HEMORRHAGIC STROKE; PUMP THROMBOSIS; MORTALITY; HEMOLYSIS;
D O I
10.1016/j.jtcvs.2018.06.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Stroke is one of the major adverse events after left ventricular assist device implantation. Risk of stroke is the highest immediately after left ventricular assist device implantation and then increases again in chronic periods. There is no study that has analyzed risk factors for stroke in acute phase. We investigated the risk factors for stroke in the acute phase after left ventricular assist device implantation in the present study. Methods: Between October 2005 and December 2016, 158 consecutive patients (mean age, 43 +/- 14 years; 34% were women) underwent continuous-flow left ventricular assist device (50 HeartMate II [Abbott Medical, Abbott Park, III], 38 DuraHeart [Terumo Heart, Ann Arbor, Mich], 33 Jarvik2000 [Jarvik Heart, New York, NY], 23 EVAHEART [Sun Medical, Moriyama City, Japan], 14 HeartWare [Framingham, Mass]) implantation in our institution. We analyzed the risk factors for a symptomatic stroke within 90 days after left ventricular assist device implantation. Results: Stroke occurred in 28 patients in the acute phase after left ventricular assist device implantation. Multivariate analysis revealed that low cardiac output (odds ratio, 0.25; 0.07-0.92; P = .024) during postoperative 12 to 24 hours was the only independent risk factor for stroke in the acute phase. Patients with stroke in the acute phase had higher serum lactate dehydrogenase levels at any point until postoperative 14 days. Patients with the HeartMate II device particularly showed a statistically significant negative relationship between cardiac output during postoperative 12 to 24 hours and serum lactate dehydrogenase levels at postoperative 14 days (r = -0.313, P = .03). Conclusions: Our study demonstrated that patients with perioperative lower cardiac output and higher lactate dehydrogenase level developed stroke in the acute phase after left ventricular assist device implantation. These results suggested that maintenance of sufficient left ventricular assist device flow is important in prevention of stroke, which may be related to subclinical pump thrombosis.
引用
收藏
页码:259 / +
页数:10
相关论文
共 50 条
  • [11] Risk Factors Predictive of Right Ventricular Failure After Left Ventricular Assist Device Implantation
    Drakos, Stavros G.
    Janicki, Lindsay
    Horne, Benjamin D.
    Kfoury, Abdallah G.
    Reid, Bruce B.
    Clayson, Stephen
    Horton, Kenneth
    Haddad, Francois
    Li, Dean Y.
    Renlund, Dale G.
    Fisher, Patrick W.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (07): : 1030 - 1035
  • [12] Calculation of the ALMA Risk of Right Ventricular Failure After Left Ventricular Assist Device Implantation
    Loforte, Antonio
    Montalto, Andrea
    Musumeci, Francesco
    Amarelli, Cristiano
    Mariani, Carlo
    Polizzi, Vincenzo
    Della Monica, Paola Lilla
    Grigioni, Francesco
    Di Bartolomeo, Roberto
    Marinelli, Giuseppe
    ASAIO JOURNAL, 2018, 64 (06) : E140 - E147
  • [13] Ventricular arrhythmia characteristics after left ventricular assist device implantation
    Li, X.
    Qing, P.
    Du, J.
    Zou, L.
    Zhou, X. T.
    Chen, H. B.
    Duan, F. J.
    Yu, L. T.
    Yao, Y.
    Wang, X. Q.
    Hu, S. S.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [14] Ventricular arrhythmia characteristics after left ventricular assist device implantation
    Li, X.
    Qing, P.
    Du, J.
    Zou, L.
    Zhou, X. T.
    Chen, H. B.
    Duan, F. J.
    Yu, L. T.
    Yao, Y.
    Wang, X. Q.
    Hu, S. S.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [15] Ischemic And Hemorrhagic Stroke In Patients With Implantation Of Left Ventricular Assist Device
    Sakaguchi, Manabu
    Kitagawa, Kazuo
    Mochiduki, Hideki
    Sawa, Yoshiki
    Yoshimine, Toshiki
    STROKE, 2013, 44 (02)
  • [16] Right heart failure after left ventricular assist device implantation: early and late
    MacGowan, Guy A.
    Schueler, Stephan
    CURRENT OPINION IN CARDIOLOGY, 2012, 27 (03) : 296 - 300
  • [17] Colonic Perforation After Left Ventricular Assist Device Implantation
    Uysal, A.
    Qureshi, M.
    Dumitru, I.
    Bandyopadhyay, D.
    Mathew, D.
    Mencer, N.
    Prater, J.
    Arslan, A.
    Hunley, C.
    Uysal, L.
    Lama, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S492 - S492
  • [18] Hospital Readmissions After Left Ventricular Assist Device Implantation
    Heim, C.
    Mekkhala, N.
    Kondruweit, M.
    Weyand, M.
    Tandler, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S340 - S341
  • [19] Driveline Infections after Implantation of a Left Ventricular Assist Device
    Vandersmissen, K.
    Roppe, M.
    Droogne, W.
    Jacobs, S.
    Meyns, B.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S394 - S394
  • [20] Inhaled Milrinone After Left Ventricular Assist Device Implantation
    Haglund, Nicholas A.
    Burdorf, Adam
    Jones, Tara
    Shostrom, Valerie
    Um, John
    Ryan, Timothy
    Shillcutt, Sasha
    Fischer, Patricia
    Cox, Zachary L.
    Raichlin, Eugenia
    Lowes, Brian D.
    Dumitru, Ioana