Inhaled Milrinone After Left Ventricular Assist Device Implantation

被引:29
|
作者
Haglund, Nicholas A. [1 ]
Burdorf, Adam [1 ]
Jones, Tara [1 ]
Shostrom, Valerie [1 ]
Um, John [2 ]
Ryan, Timothy [2 ]
Shillcutt, Sasha [3 ]
Fischer, Patricia [1 ]
Cox, Zachary L. [4 ]
Raichlin, Eugenia [1 ]
Lowes, Brian D. [1 ]
Dumitru, Ioana [1 ]
机构
[1] Vanderbilt Univ, Div Cardiol, Med Ctr, Nashville, TN 37232 USA
[2] Univ Nebraska Med Ctr, Cardiovasc Surg, Omaha, NE USA
[3] Univ Nebraska Med Ctr, Dept Anesthesiol, Omaha, NE USA
[4] Lipscomb Univ, Coll Pharm, Pharm Practice, Nashville, TN USA
关键词
Phosphodiesterase inhibitor; nebulization; right ventricular dysfunction; left ventricular assist device; HEART-FAILURE; RISK SCORE; THERAPY;
D O I
10.1016/j.cardfail.2015.04.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Proven strategies to reduce right ventricular (RV) dysfunction after continuous-flow left ventricular assist device (CF-LVAD) implantation are lacking. We sought to evaluate the tolerability, feasibility, efficacy, and pharmacokinetics of inhaled milrinone (iMil) delivery after CF-LVAD implantation. Methods and Results: We prospectively evaluated fixed-dose nebulized iMil delivered into a ventilator circuit for 24 hours in 10 postoperative CF-LVAD (Heartmate-II) patients. Tolerability (arrhythmias, hypotension, and hypersensitivity reaction), efficacy (hemodynamics), pharmacoldnetics (plasma milrinone levels), and cost data were collected.Mean age was 56 +/- 9 years, 90% were male, and mean. INTERMACS profile was 2.5 +/- 0.8. No new atrial arrhythmia events occurred, although 3 (30%) ventricular tachycardia (1 nonsustained, 2 sustained) events occurred. Sustained hypotension, drug hypersensitivity, death, or need for right ventricular assist device were not observed. Invasive mean pulmonary arterial pressure from baseline to during iMil therapy was improved (P = .017). Mean plasma milrinone levels (ng/mL) at baseline, and 1, 4, 8, 12, and 24 hours were 74.2 +/- 35.4, 111.3 +/- 70.9, 135.9 +/- 41.5, 205.0 +/- 86.7, 176.8 +/- 61.3 187.6 +/- 105.5, respectively. Reduced institutional cost was observed when iMil was compared with nitric oxide therapy over 24 hours ($165.29 vs $1,944.00, respectively). Conclusions: iMil delivery after CF-LVAD implantation was well tolerated, feasible, and demonstrated favorable hemodynamic, pharmacokinetic, and cost profiles. iMil therapy warrants further study in larger clinical trials.
引用
收藏
页码:792 / 797
页数:6
相关论文
共 50 条
  • [1] Inhaled Milrinone After Left Ventricular Assist Device Implantation (vol 21, pg 792, 2015)
    Haglund, Nicholas A.
    Burdorf, Adam
    Jones, Tara
    Shostrom, Valerie
    Um, John
    Ryan, Timothy
    Shillcutt, Sasha
    Fischer, Patricia
    Cox, Zachary L.
    Raichlin, Eugenia
    Anderson, Daniel R.
    Lowes, Brian D.
    Dumitru, Ioana
    [J]. JOURNAL OF CARDIAC FAILURE, 2016, 22 (03) : 246 - 246
  • [2] Effects of milrinone for right ventricular failure after left ventricular assist device implantation
    Kihara, S
    Kawai, A
    Fukuda, T
    Yamamoto, N
    Aomi, S
    Nishida, H
    Endo, M
    Koyanagi, H
    [J]. HEART AND VESSELS, 2002, 16 (02) : 69 - 71
  • [3] Effects of milrinone for right ventricular failure after left ventricular assist device implantation
    S. Kihara
    Akihiko Kawai
    Takuya Fukuda
    Noboru Yamamoto
    Shigeyuki Aomi
    Hiroshi Nishida
    Masahiro Endo
    Hitoshi Koyanagi
    [J]. Heart and Vessels, 2002, 16 : 69 - 71
  • [4] Outcomes of Patients with Right Ventricular Failure on Milrinone After Left Ventricular Assist Device Implantation
    Tsiouris, Athanasios
    Paone, Gaetano
    Brewer, Robert J.
    Nemeh, Hassan W.
    Borgi, Jamil
    Morgan, Jeffrey A.
    [J]. ASAIO JOURNAL, 2015, 61 (02) : 133 - 138
  • [5] Outcome of Patients with Right Ventricular Failure on Milrinone after Left Ventricular Assist Device Implantation
    Morgan, J. A.
    Brewer, R. J.
    Nemeh, H. W.
    Henry, S. E.
    Williams, C. T.
    Lanfear, D. E.
    Tita, C.
    Velez, M.
    Selektor, Y.
    Paone, G.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S282 - S282
  • [6] Ventricular arrhythmias after left ventricular assist device implantation
    Refaat, Marwan
    Chemaly, Elie
    Lebeche, Djamel
    Gwathmey, Judith K.
    Hajjar, Roger J.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (10): : 1246 - 1252
  • [7] Driving After Left Ventricular Assist Device Implantation
    Hanke, Jasmin S.
    Riebandt, Julia
    Wahabzada, Miena
    Nur, Fatma
    Wahabzada, Angela
    Dogan, Guenes
    Feldmann, Christina
    Haverich, Axel
    Popov, Aron-Friedrich
    Zimpfer, Daniel
    Schmitto, Jan D.
    [J]. ARTIFICIAL ORGANS, 2018, 42 (07) : 695 - 699
  • [8] Flying after left ventricular assist device implantation
    Hanke, Jasmin S.
    Schmack, Bastian
    Merzah, Ali Saad
    Bounader, Karl
    Chatterjee, Anamika
    Mariani, Silvia
    Li, Tong
    Klautzsch, Erik
    Mueller, Florian
    Homann, Katharina
    Schoede, Alexandra
    Haverich, Axel
    Ruhparwar, Arjang
    Schmitto, Jan D.
    Dogan, Guenes
    [J]. ARTIFICIAL ORGANS, 2021, 45 (03) : 230 - 235
  • [9] Dialysis After Left Ventricular Assist Device Implantation
    Tsay, Annie
    Ober, Lori
    Soleimani, Behzad
    Dowling, Robert
    Shouey, Jordan
    Ali, Omaima
    Scanlon, Thomas
    Oblender, Robert
    Eisen, Howard Joel
    [J]. JOURNAL OF CARDIAC FAILURE, 2020, 26 (10) : S153 - S154
  • [10] Left ventricular assist device implantation in patients after left ventricular reconstruction
    Palmen, Meindert
    Braun, Jerry
    Beeres, Saskia L. M. A.
    Klautz, Robert J. M.
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 23 (06) : 979 - 981