Risk of stroke early after implantation of a left ventricular assist device

被引:10
|
作者
Samura, Takaaki [1 ]
Yoshioka, Daisuke [1 ]
Toda, Koichi [1 ]
Sakaniwa, Ryoto [2 ]
Shimizu, Mikito [3 ]
Miyagawa, Shigeru [1 ]
Yoshikawa, Yasushi [1 ]
Hata, Hiroki [1 ]
Saito, Shunsuke [1 ]
Sakata, Yasushi [4 ]
Sawa, Yoshiki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Yamadaoka 2-2, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Publ Hlth, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Neurol, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Cardiol, Osaka, Japan
来源
关键词
left ventricular assist device; low cardiac output; pump thrombosis; stroke; HEART MATE II; INTERAGENCY REGISTRY; HEMORRHAGIC STROKE; PUMP THROMBOSIS; MORTALITY; HEMOLYSIS;
D O I
10.1016/j.jtcvs.2018.06.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Stroke is one of the major adverse events after left ventricular assist device implantation. Risk of stroke is the highest immediately after left ventricular assist device implantation and then increases again in chronic periods. There is no study that has analyzed risk factors for stroke in acute phase. We investigated the risk factors for stroke in the acute phase after left ventricular assist device implantation in the present study. Methods: Between October 2005 and December 2016, 158 consecutive patients (mean age, 43 +/- 14 years; 34% were women) underwent continuous-flow left ventricular assist device (50 HeartMate II [Abbott Medical, Abbott Park, III], 38 DuraHeart [Terumo Heart, Ann Arbor, Mich], 33 Jarvik2000 [Jarvik Heart, New York, NY], 23 EVAHEART [Sun Medical, Moriyama City, Japan], 14 HeartWare [Framingham, Mass]) implantation in our institution. We analyzed the risk factors for a symptomatic stroke within 90 days after left ventricular assist device implantation. Results: Stroke occurred in 28 patients in the acute phase after left ventricular assist device implantation. Multivariate analysis revealed that low cardiac output (odds ratio, 0.25; 0.07-0.92; P = .024) during postoperative 12 to 24 hours was the only independent risk factor for stroke in the acute phase. Patients with stroke in the acute phase had higher serum lactate dehydrogenase levels at any point until postoperative 14 days. Patients with the HeartMate II device particularly showed a statistically significant negative relationship between cardiac output during postoperative 12 to 24 hours and serum lactate dehydrogenase levels at postoperative 14 days (r = -0.313, P = .03). Conclusions: Our study demonstrated that patients with perioperative lower cardiac output and higher lactate dehydrogenase level developed stroke in the acute phase after left ventricular assist device implantation. These results suggested that maintenance of sufficient left ventricular assist device flow is important in prevention of stroke, which may be related to subclinical pump thrombosis.
引用
收藏
页码:259 / +
页数:10
相关论文
共 50 条
  • [31] Preoperative Risk Factors for Postoperative Infection after Left Ventricular Assist Device Implantation
    Raina, A.
    Kanwar, M.
    Sokos, G. G.
    Hopwood, A.
    Bhanot, N.
    Moraca, R. J.
    Bailey, S.
    Murali, S.
    Benza, R. L.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S198 - S198
  • [32] Independent risk factors for ICU mortality after left ventricular assist device implantation
    Piffard, Marianne
    Nubret-Le Coniat, Karine
    Simon, Olivier
    Leuillet, Sebastien
    Remy, Alain
    Barandon, Laurent
    Ouattara, Alexandre
    ARTIFICIAL ORGANS, 2020, 44 (02) : 153 - 161
  • [33] Risk Factors for the Development of Severe Hyperbilirubinemia after Left Ventricular Assist Device Implantation
    Cogswell, R.
    Gupta, S.
    Ramu, B.
    Burns, M.
    Martin, C.
    Thenappan, T.
    John, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S266 - S266
  • [34] Stroke after left ventricular assist device for long-term implantation: A case report
    Polin, M.
    Braga, G. P.
    Luvizutto, G. J.
    Fusco, D. R.
    Cicchetto, L. A. F.
    Hueb, J. C.
    Bazan, S. G. Z.
    Bazan, R.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 200 - 201
  • [35] Massive air embolism resulting in ischemic stroke after left ventricular assist device implantation
    Bansal, Aditya
    Akhtar, Faisal
    Zwintscher, Nathan P.
    Bansal, Arnav
    Verma, Arjun
    Sabharwal, Vivek
    JOURNAL OF CARDIAC SURGERY, 2019, 34 (11) : 1393 - 1395
  • [36] Stroke After Left Ventricular Assist Device Implantation: Outcomes in the Continuous-Flow Era
    Harvey, Laura
    Holley, Christopher
    Roy, Samit S.
    Eckman, Peter
    Cogswell, Rebecca
    Liao, Kenneth
    John, Ranjit
    ANNALS OF THORACIC SURGERY, 2015, 100 (02): : 535 - 541
  • [37] Preoperative Risk Factors for Stroke After HeartWare Left Ventricular Assist Device Implantation: Texas Heart Institute Experience
    Ono, M.
    Singh, S. K.
    Cohn, W. E.
    Civitello, A. B.
    Frazier, O.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S240 - S241
  • [38] Intracardiac Shunt Reversal and Early Right Ventricular Failure after Left Ventricular Assist Device Implantation
    Pillai, Ashwin
    Jedeon, Zeina
    Hammond, Jonathan
    Gluck, Jason
    Jaiswal, Abhishek
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [39] Open Chest Epicardial Ablation of Ventricular Tachycardia Early after Left Ventricular Assist Device Implantation
    Shabari, F. Raissi
    Yousef, J.
    Cohn, W.
    Gregoric, I.
    Frazier, O. H.
    Cheng, J.
    Mathuria, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S272 - S272
  • [40] Early Intraoperative Detection and Management of Right Ventricular Failure After Left Ventricular Assist Device Implantation
    Powell, Thomas R.
    TEXAS HEART INSTITUTE JOURNAL, 2023, 50 (04)