Risk of stroke early after implantation of a left ventricular assist device

被引:10
|
作者
Samura, Takaaki [1 ]
Yoshioka, Daisuke [1 ]
Toda, Koichi [1 ]
Sakaniwa, Ryoto [2 ]
Shimizu, Mikito [3 ]
Miyagawa, Shigeru [1 ]
Yoshikawa, Yasushi [1 ]
Hata, Hiroki [1 ]
Saito, Shunsuke [1 ]
Sakata, Yasushi [4 ]
Sawa, Yoshiki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Yamadaoka 2-2, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Publ Hlth, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Neurol, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Cardiol, Osaka, Japan
来源
关键词
left ventricular assist device; low cardiac output; pump thrombosis; stroke; HEART MATE II; INTERAGENCY REGISTRY; HEMORRHAGIC STROKE; PUMP THROMBOSIS; MORTALITY; HEMOLYSIS;
D O I
10.1016/j.jtcvs.2018.06.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Stroke is one of the major adverse events after left ventricular assist device implantation. Risk of stroke is the highest immediately after left ventricular assist device implantation and then increases again in chronic periods. There is no study that has analyzed risk factors for stroke in acute phase. We investigated the risk factors for stroke in the acute phase after left ventricular assist device implantation in the present study. Methods: Between October 2005 and December 2016, 158 consecutive patients (mean age, 43 +/- 14 years; 34% were women) underwent continuous-flow left ventricular assist device (50 HeartMate II [Abbott Medical, Abbott Park, III], 38 DuraHeart [Terumo Heart, Ann Arbor, Mich], 33 Jarvik2000 [Jarvik Heart, New York, NY], 23 EVAHEART [Sun Medical, Moriyama City, Japan], 14 HeartWare [Framingham, Mass]) implantation in our institution. We analyzed the risk factors for a symptomatic stroke within 90 days after left ventricular assist device implantation. Results: Stroke occurred in 28 patients in the acute phase after left ventricular assist device implantation. Multivariate analysis revealed that low cardiac output (odds ratio, 0.25; 0.07-0.92; P = .024) during postoperative 12 to 24 hours was the only independent risk factor for stroke in the acute phase. Patients with stroke in the acute phase had higher serum lactate dehydrogenase levels at any point until postoperative 14 days. Patients with the HeartMate II device particularly showed a statistically significant negative relationship between cardiac output during postoperative 12 to 24 hours and serum lactate dehydrogenase levels at postoperative 14 days (r = -0.313, P = .03). Conclusions: Our study demonstrated that patients with perioperative lower cardiac output and higher lactate dehydrogenase level developed stroke in the acute phase after left ventricular assist device implantation. These results suggested that maintenance of sufficient left ventricular assist device flow is important in prevention of stroke, which may be related to subclinical pump thrombosis.
引用
收藏
页码:259 / +
页数:10
相关论文
共 50 条
  • [21] Anticoagulation Therapy After Left Ventricular Assist Device Implantation
    Tanoue, Yoshihisa
    Fujino, Takeo
    Shiose, Akira
    CIRCULATION JOURNAL, 2018, 82 (05) : 1245 - 1246
  • [22] QRS Shortens after Left Ventricular Assist Device Implantation
    Guirguis, Baher
    Stout, Megan
    Elayi, Claude S.
    Omar, Hesham R.
    Guglin, Maya
    ASAIO JOURNAL, 2019, 65 (07) : E66 - E68
  • [23] Subxyphoidal Hernia After Left Ventricular Assist Device Implantation
    Dziodzio, Tomasz
    Fehrenbach, Uli
    Jara, Maximilian
    Oellinger, Robert
    Pratschke, Johann
    Neudecker, Jens
    Fikatas, Panagiotis
    ANNALS OF THORACIC SURGERY, 2020, 110 (04): : E347 - E347
  • [24] Wound complications after left ventricular assist device implantation
    Tjan, TDT
    Asfour, B
    Hammel, D
    Schmidt, C
    Scheld, HH
    Schmid, C
    ANNALS OF THORACIC SURGERY, 2000, 70 (02): : 538 - 541
  • [25] Hospital readmissions after left ventricular assist device implantation
    Lesny, P.
    Luknar, M.
    Simovicova, V.
    Dankova, M.
    Goncalvesova, E.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 91 - 91
  • [26] Hospital readmissions after left ventricular assist device implantation
    Heim, Christian
    Mekkhala, Nattipong
    Kondruweit, Markus
    Weyand, Michael
    Tandler, Rene
    TRANSPLANTATION, 2016, 100 (07) : S41 - S41
  • [27] Postoperative management after implantation of a left ventricular assist device
    Pilarczyk, K.
    Pizanis, N.
    Kamler, M.
    Jakob, H. G.
    Beyersdorf, F.
    Trummer, G.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2014, 28 (05): : 337 - 346
  • [28] Outcomes and Complications after Left Ventricular Assist Device Implantation
    Wasilewski, Grzegorz
    Wisniowska-Smialek, Sylwia
    Gorkiewicz-Kot, Izabela
    Milaniak, Irena
    Kaleta, Michal
    Hymczak, Hubert
    Tomsia, Paulina
    Wierzbicki, Karol
    TRANSPLANTATION PROCEEDINGS, 2024, 56 (04) : 864 - 867
  • [29] Changes in Spirometry After Left Ventricular Assist Device Implantation
    Mohamedali, Burhan
    Bhat, Geetha
    Yost, Gardner
    Tatooles, Antone
    ARTIFICIAL ORGANS, 2015, 39 (12) : 1046 - 1050
  • [30] Pulmonary embolism after implantation of the left ventricular assist device
    Xiong, Xinghui
    Zhou, Ruihao
    Deng, Lijing
    ASIAN JOURNAL OF SURGERY, 2024, 47 (09) : 4226 - 4228