Contact and Non-contact Heart Beat Rate Measurement Techniques: Challenges and Issues

被引:1
|
作者
Khong, Wei Leong [1 ]
Mariappan, Muralindran [2 ]
Chong, Chee Siang [2 ]
机构
[1] Monash Univ Malaysia, Sch Engn, Subang Jaya 47500, Selangor, Malaysia
[2] Univ Malaysia Sabah, Fac Engn, Kota Kinabalu 88400, Sabah, Malaysia
来源
关键词
Electrocardiogram; heart beat rate; oscillometric method; photoplethysmography imaging; photoplethysmography; BLOOD-PRESSURE; PHOTOPLETHYSMOGRAPHY; HISTORY;
D O I
10.47836/pjst.29.3.03
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The heart is the most important organ in the human body as it circulates the blood throughout the body through blood vessels. In the human circulatory system, the heart beats according to the body's physical needs. Therefore, the physical condition of a person can be determined by observing the heartbeat rate (HBR). There are plenty of methods that can be used to measure the HBR. Among the methods, photoplethysmography (PPG), electrocardiogram (ECG) and the oscillometric method are the standard methods utilised in medical institutes for continuous measurement of the HBR of a patient. Out of these three methods, PPG is the only method which has evolved to a non-contact imaging-based method from the conventional contact sensory based method. The incentive for developing the non-contact-based imaging PPG method in measuring the HBR provides the advantage of excluding the direct contact of sensors on specific body parts. This brings huge improvements to remote monitoring of healthcare especially for the purpose of social distancing. Moreover, the rapid progression of technology (particularly the interactive electronic gadgets advancement) also motivates researchers and engineers to create a mobile application using the PPG imaging method, which is feasible in measuring the HBR. Hence, this study seeks to review and present the fundamental concept, the present research and the evolution of the aforementioned methods in measuring the HBR.
引用
收藏
页码:1707 / 1732
页数:26
相关论文
共 50 条
  • [31] Measurement of hand-vibration transmissibility by non-contact measurement techniques
    Nataletti, P
    Paone, N
    Scalise, L
    ENVIRONMENTAL HEALTH RISK III, 2005, 9 : 315 - 324
  • [32] Driver Drowsiness Detection Based on Facial Video Non-Contact Heart Rate Measurement
    Ding, Fusheng
    Qin, Yanbin
    Zhang, Lanxiang
    Lyu, Hongming
    JOURNAL OF ADVANCED COMPUTATIONAL INTELLIGENCE AND INTELLIGENT INFORMATICS, 2025, 29 (02) : 306 - 315
  • [33] Measurement uncertainty of contact and non-contact techniques on condition monitoring of complex industrial components
    D'Emilia, G.
    Gaspari, A.
    Natale, E.
    PROCEEDINGS OF THE XXV A.I.VE.LA. ANNUAL MEETING, 2018, 1110
  • [34] Non-contact temperature measurement
    Metallurgia, 1995, 62 (02):
  • [35] Combination of Denoising Algorithms for Video-Based Non-contact Heart Rate Measurement
    Xiao, Han
    Xu, Jie
    Hu, Danfeng
    Wang, Jiajun
    2022 3RD INFORMATION COMMUNICATION TECHNOLOGIES CONFERENCE (ICTC 2022), 2022, : 141 - 145
  • [36] Accuracy of a reverse-engineered mould using contact and non-contact measurement techniques
    Mian, Syed Hammad
    Mannan, M. A.
    Al-Ahmari, Abdulrahman
    INTERNATIONAL JOURNAL OF COMPUTER INTEGRATED MANUFACTURING, 2015, 28 (05) : 419 - 436
  • [37] Non-contact Measurement of Human Heart Rate Using Low Cost Video Camera
    Sharma, Naveen
    Kaman, Surjit
    Mahapatra, Prasant K.
    2019 FIFTH INTERNATIONAL CONFERENCE ON IMAGE INFORMATION PROCESSING (ICIIP 2019), 2019, : 58 - 62
  • [38] NON-CONTACT SPEED MEASUREMENT
    KENYON, M
    VANHOEK, HC
    PORTER, CA
    AUSTRALIAN JOURNAL OF INSTRUMENTATION & CONTROL, 1981, 37 (06): : 114 - 117
  • [39] PROGRESS IN NON-CONTACT MEASUREMENT
    LEWIS, GE
    CME-CHARTERED MECHANICAL ENGINEER, 1981, 28 (08): : 31 - 32
  • [40] Non-contact temperatures measurement
    Materiales de Construccion, 62 (238):