Combination of Denoising Algorithms for Video-Based Non-contact Heart Rate Measurement

被引:2
|
作者
Xiao, Han [1 ]
Xu, Jie [1 ]
Hu, Danfeng [1 ]
Wang, Jiajun [1 ]
机构
[1] Suzhou Univ, Sch Elect & Informat Engn, Suzhou, Peoples R China
关键词
image photoplethysmography; wavelet transform; principal component analysis; independent component analysis;
D O I
10.1109/ICTC55111.2022.9778685
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Denoising is very important for signal processing of non-contact heart rate measurement. Most studies of video-based heart rate measurement usually use a single denoising algorithm such as principal component analysis (PCA) or independent component analysis (ICA) to reduce noise in original signal. Using only one single denoising algorithm usually can not achieve satisfactory results, because each denoising algorithm has its shortcomings. To deal with this problem, this study has proposed to combine the following three denoising algorithms of wavelet transform (WT), PCA and ICA in different ways for noise removal in the original heart rate signal. The denoising performance is evaluated by root mean square error (RMSE) and mean absolute error (MAE). The experimental results have shown that the measurement accuracy of combined algorithms is higher than that of single algorithm. The proposed combined denoising algorithm in this study can improve accuracy and enhance stability of heart rate measurement, which is of practical significance for the application of non-contact heart rate measurement technology.
引用
收藏
页码:141 / 145
页数:5
相关论文
共 50 条
  • [1] Non-contact Measurement of Heart Rate Based on Facial Video
    Wang, Cheng
    Jiang, Yuling
    Cai, Zhuohao
    Lin, Lan
    [J]. 2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2019, : 2269 - 2275
  • [2] Non-contact Video-based Pulse Rate Measurement on a Mobile Service Robot
    Stricker, Ronny
    Mueller, Steffen
    Gross, Horst-Michael
    [J]. 2014 23RD IEEE INTERNATIONAL SYMPOSIUM ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION (IEEE RO-MAN), 2014, : 1056 - 1062
  • [3] Non-contact video-based estimation of heart rate variability spectrogram from hemoglobin composition
    Fukunishi M.
    Kurita K.
    Yamamoto S.
    Tsumura N.
    [J]. Artificial Life and Robotics, 2017, 22 (4) : 457 - 463
  • [4] A Comparative Study of Video Signals for Non-contact Heart Rate Measurement
    Lueangwattana, Chanya
    Kondo, Toshiaki
    Haneishi, Hideaki
    [J]. 2015 12TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2015,
  • [5] Non-contact measurement of the heart rate and the heart rate variability
    Kranjec, Jure
    Begus, Samo
    Gersak, Gregor
    Drnovsek, Janko
    [J]. ELEKTROTEHNISKI VESTNIK, 2013, 80 (03): : 135 - 140
  • [6] Non-Contact Video-Based Neonatal Respiratory Monitoring
    Rossol, Scott L.
    Yang, Jeffrey K.
    Toney-Noland, Caroline
    Bergin, Janine
    Basavaraju, Chandan
    Kumar, Pavan
    Lee, Henry C.
    [J]. CHILDREN-BASEL, 2020, 7 (10):
  • [7] Non-contact heart rate measurement from face video based on group sparse representation
    Ou, Weihua
    Chen, Longbao
    Xiong, Jiahao
    Han, Jie
    Zeng, Wu
    Gou, Jianping
    [J]. DIGITAL SIGNAL PROCESSING, 2024, 144
  • [8] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    [J]. JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [9] Video-Based Deception Detection with Non-Contact Heart Rate Monitoring and Multi-Modal Feature Selection
    Yanfeng Li
    Jincheng Bian
    Yiqun Gao
    Rencheng Song
    [J]. Journal of Beijing Institute of Technology, 2024, (03) - 185
  • [10] Non-contact Measurement of Human Heart Rate Using Low Cost Video Camera
    Sharma, Naveen
    Kaman, Surjit
    Mahapatra, Prasant K.
    [J]. 2019 FIFTH INTERNATIONAL CONFERENCE ON IMAGE INFORMATION PROCESSING (ICIIP 2019), 2019, : 58 - 62