Contact and Non-contact Heart Beat Rate Measurement Techniques: Challenges and Issues

被引:1
|
作者
Khong, Wei Leong [1 ]
Mariappan, Muralindran [2 ]
Chong, Chee Siang [2 ]
机构
[1] Monash Univ Malaysia, Sch Engn, Subang Jaya 47500, Selangor, Malaysia
[2] Univ Malaysia Sabah, Fac Engn, Kota Kinabalu 88400, Sabah, Malaysia
来源
关键词
Electrocardiogram; heart beat rate; oscillometric method; photoplethysmography imaging; photoplethysmography; BLOOD-PRESSURE; PHOTOPLETHYSMOGRAPHY; HISTORY;
D O I
10.47836/pjst.29.3.03
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The heart is the most important organ in the human body as it circulates the blood throughout the body through blood vessels. In the human circulatory system, the heart beats according to the body's physical needs. Therefore, the physical condition of a person can be determined by observing the heartbeat rate (HBR). There are plenty of methods that can be used to measure the HBR. Among the methods, photoplethysmography (PPG), electrocardiogram (ECG) and the oscillometric method are the standard methods utilised in medical institutes for continuous measurement of the HBR of a patient. Out of these three methods, PPG is the only method which has evolved to a non-contact imaging-based method from the conventional contact sensory based method. The incentive for developing the non-contact-based imaging PPG method in measuring the HBR provides the advantage of excluding the direct contact of sensors on specific body parts. This brings huge improvements to remote monitoring of healthcare especially for the purpose of social distancing. Moreover, the rapid progression of technology (particularly the interactive electronic gadgets advancement) also motivates researchers and engineers to create a mobile application using the PPG imaging method, which is feasible in measuring the HBR. Hence, this study seeks to review and present the fundamental concept, the present research and the evolution of the aforementioned methods in measuring the HBR.
引用
收藏
页码:1707 / 1732
页数:26
相关论文
共 50 条
  • [41] NON-CONTACT MEASUREMENT BY RADIOACTIVITY
    BOND, A
    PROCESS ENGINEERING, 1975, (MAR) : 62 - 63
  • [42] Non-contact temperature measurement
    不详
    INDUSTRIAL CERAMICS, 2001, 21 (01): : 56 - 56
  • [43] Non-contact Viscosity Measurement using Sensor Fusion Techniques
    Santhosh, K., V
    Prajwal, Kovoor
    2017 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING, INSTRUMENTATION AND CONTROL TECHNOLOGIES (ICICICT), 2017, : 677 - 680
  • [44] Non-contact respiratory rate and heart rate signal acquisition system
    Guo J.
    Chen Y.-H.
    Wang L.-R.
    Wei Y.
    Guo Y.
    Zhao Y.-M.
    Liu L.-L.
    Chen X.-H.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (06): : 1354 - 1361
  • [45] Application of non-contact geodetic measurement techniques in dam monitoring
    Zaczek-Peplinska, Janina
    Kowalska, Maria
    ARCHIVES OF CIVIL ENGINEERING, 2022, 68 (03) : 49 - 70
  • [46] Non-contact, synchronous dynamic measurement of respiratory rate and heart rate based on dual sensitive regions
    Bing Wei
    Xuan He
    Chao Zhang
    Xiaopei Wu
    BioMedical Engineering OnLine, 16
  • [47] Non-contact uplift measurement at overhead contact lines
    Hietzge, Jochen
    Stephan, Arnd
    eb - Elektrische Bahnen, 2007, 105 (4-5): : 276 - 279
  • [48] Non-contact, synchronous dynamic measurement of respiratory rate and heart rate based on dual sensitive regions
    Wei, Bing
    He, Xuan
    Zhang, Chao
    Wu, Xiaopei
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [49] Non-Contact Respiratory Rate Measurement Validation for Hospitalized Patients
    Droitcour, Amy D.
    Seto, Todd B.
    Park, Byung-Kwon
    Yamada, Shuhei
    Vergara, Alex
    El Hourani, Charles
    Shing, Tommy
    Yuen, Andrea
    Lubecke, Victor M.
    Boric-Lubecke, Olga
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4812 - +
  • [50] Non-contact Heart Rate Measurements Based on Skin Detection
    Zhao Ting
    Zhou Zuofeng
    Chen Pengyong
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806