Contact and Non-contact Heart Beat Rate Measurement Techniques: Challenges and Issues

被引:1
|
作者
Khong, Wei Leong [1 ]
Mariappan, Muralindran [2 ]
Chong, Chee Siang [2 ]
机构
[1] Monash Univ Malaysia, Sch Engn, Subang Jaya 47500, Selangor, Malaysia
[2] Univ Malaysia Sabah, Fac Engn, Kota Kinabalu 88400, Sabah, Malaysia
来源
关键词
Electrocardiogram; heart beat rate; oscillometric method; photoplethysmography imaging; photoplethysmography; BLOOD-PRESSURE; PHOTOPLETHYSMOGRAPHY; HISTORY;
D O I
10.47836/pjst.29.3.03
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The heart is the most important organ in the human body as it circulates the blood throughout the body through blood vessels. In the human circulatory system, the heart beats according to the body's physical needs. Therefore, the physical condition of a person can be determined by observing the heartbeat rate (HBR). There are plenty of methods that can be used to measure the HBR. Among the methods, photoplethysmography (PPG), electrocardiogram (ECG) and the oscillometric method are the standard methods utilised in medical institutes for continuous measurement of the HBR of a patient. Out of these three methods, PPG is the only method which has evolved to a non-contact imaging-based method from the conventional contact sensory based method. The incentive for developing the non-contact-based imaging PPG method in measuring the HBR provides the advantage of excluding the direct contact of sensors on specific body parts. This brings huge improvements to remote monitoring of healthcare especially for the purpose of social distancing. Moreover, the rapid progression of technology (particularly the interactive electronic gadgets advancement) also motivates researchers and engineers to create a mobile application using the PPG imaging method, which is feasible in measuring the HBR. Hence, this study seeks to review and present the fundamental concept, the present research and the evolution of the aforementioned methods in measuring the HBR.
引用
收藏
页码:1707 / 1732
页数:26
相关论文
共 50 条
  • [21] Non-contact measurement techniques for structural health monitoring
    Ong, W. H.
    Chiu, W. K.
    INTERNATIONAL CONFERENCE ON MATERIALS FOR ADVANCED TECHNOLOGIES (ICMAT2013), SYMPOSIUM W - ADVANCED STRUCTURAL AND FUNCTIONAL MATERIALS FOR PROTECTION, 2014, 75 : 45 - 50
  • [22] Non-contact detection of human heart rate with Kinect
    Liqian Zhou
    Ming Yin
    Xi Xu
    Xinpan Yuan
    Xiaojun Liu
    Cluster Computing, 2019, 22 : 8199 - 8206
  • [23] Non-Contact Method of Heart Rate Using a Webcam
    Zhao, Jin
    Huang, Jifeng
    Jia, Guoqing
    Ji, Xiaohong
    Shan, Lianhai
    IEEE 2018 INTERNATIONAL CONGRESS ON CYBERMATICS / 2018 IEEE CONFERENCES ON INTERNET OF THINGS, GREEN COMPUTING AND COMMUNICATIONS, CYBER, PHYSICAL AND SOCIAL COMPUTING, SMART DATA, BLOCKCHAIN, COMPUTER AND INFORMATION TECHNOLOGY, 2018, : 1902 - 1906
  • [24] Non-contact and contact measurement Quick Vision
    不详
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2001, 73 (04): : 423 - 423
  • [25] Non-contact detection of human heart rate with Kinect
    Zhou, Liqian
    Yin, Ming
    Xu, Xi
    Yuan, Xinpan
    Liu, Xiaojun
    CLUSTER COMPUTING-THE JOURNAL OF NETWORKS SOFTWARE TOOLS AND APPLICATIONS, 2019, 22 (Suppl 4): : S8199 - S8206
  • [26] Non-contact ultrasonic techniques
    Green, RE
    ULTRASONICS, 2004, 42 (1-9) : 9 - 16
  • [27] Non-contact and real-time measurement of heart rate and heart rate variability using microwave reflectometry
    Mase, A.
    Kogi, Y.
    Maruyama, T.
    Tokuzawa, T.
    Sakai, F.
    Kunugita, M.
    Koike, T.
    Hasegawa, H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (01):
  • [28] A novel non-contact heart rate measurement method based on EEMD combined with FastICA
    Shi, Yingli
    Qiu, Jian
    Peng, Li
    Han, Peng
    Luo, Kaiqing
    Liu, Dongmei
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (05)
  • [29] Non-contact and through-clothing measurement of the heart rate using ultrasound vibrocardiography
    Jeger-Madiot, Nathan
    Gateau, Jerome
    Fink, Mathias
    Ing, Ros-Kiri
    MEDICAL ENGINEERING & PHYSICS, 2017, 50 : 96 - 102
  • [30] Live embryo detection using a non-contact heart rate measurement of chicken eggs
    Bakunda, John Ngunga
    Pongchalee, Pornthep
    Sutapun, Boonsong
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS VIII, 2018, 10821