Soft x-ray tomography measurements in the Wendelstein 7-X stellarator

被引:25
|
作者
Brandt, C. [1 ]
Schilling, J. [1 ]
Thomsen, H. [1 ]
Broszat, T. [1 ]
Laube, R. [1 ]
Schroeder, T. [1 ]
Andreeva, T. [1 ]
Beurskens, M. N. A. [1 ]
Bozhenkov, S. A. [1 ]
Brunner, K. J. [1 ]
Card, A. [1 ]
Cordes, C. [1 ]
Damm, H. [1 ]
Fuchert, G. [1 ]
Gallowski, K. [1 ]
Gutzmann, R. [1 ]
Knauer, J. [1 ]
Laqua, H. P. [1 ]
Marquardt, M. [1 ]
Nelde, Ph [1 ]
Neuner, U. [1 ]
Pasch, E. [1 ]
Rahbarnia, K. [1 ]
Recknagel, J. [1 ]
Schuelke, M. [1 ]
Scott, E. R. [1 ]
Sieber, T. [1 ]
机构
[1] Max Planck Inst Plasma Phys, Wendelsteinstr 1, D-17491 Greifswald, Germany
关键词
x-ray; tomography; XMCTS; stellarator; Wendelstein; W7-X; DIAGNOSTICS;
D O I
10.1088/1361-6587/ab630d
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The soft x-ray tomography diagnostic in the stellarator Wendelstein 7-X consists of twenty pinhole cameras, up-down symmetrically arranged in a poloidal, triangular cross-section of the plasma vessel. The x-ray emissivity is measured with 16 bit amplitude resolution at 2 MHz sampling rate along 360 lines-of-sight by silicon photodiode arrays. In the recent operation campaign data acquisition (DAQ) has been working reliable for the conducted plasma pulse lengths <1 min, however the DAQ system are ready for the foreseen 30 min plasma pulse lengths of upcoming campaigns. The bandwidth of the preamplifiers is 200 kHz and the sensitive energy range is approximately 1-12 keV. The measurements indicate the up-down symmetric emissivity distribution in the triangular poloidal cross-section. First tomographic reconstructions of different magnetic field configurations are consistent with the theoretically calculated flux surface topology.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Impurity transport studies at Wendelstein 7-X by means of x-ray imaging spectrometer measurements
    Langenberg, A.
    Warmer, F.
    Fuchert, G.
    Marchuk, O.
    Dinklage, A.
    Wegner, Th
    Alonso, J. A.
    Bozhenkov, S.
    Brunner, J.
    Burhenn, R.
    Buttenschoen, B.
    Drews, P.
    Geiger, B.
    Grulke, O.
    Hirsch, M.
    Hoefel, U.
    Hollfeld, K. P.
    Killer, C.
    Knauer, J.
    Krings, T.
    Kunkel, F.
    Neuner, U.
    Offermanns, G.
    Pablant, N. A.
    Pasch, E.
    Rahbarnia, K.
    Satheeswaran, G.
    Schilling, J.
    Schweer, B.
    Thomsen, H.
    Traverso, P.
    Wolf, R. C.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2019, 61 (01)
  • [32] Determination of poloidal mode numbers of MHD modes and their radial location using a soft x-ray camera array in the Wendelstein 7-X stellarator
    Dreval, M. B.
    Brandt, C.
    Schilling, J.
    Thomsen, H.
    Beletskii, A.
    Koenies, A.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2021, 63 (06)
  • [33] Prospects of X-ray imaging spectrometers for impurity transport: Recent results from the stellarator Wendelstein 7-X (invited)
    Langenberg, A.
    Pablant, N. A.
    Wegner, Th
    Traverso, P.
    Marchuk, O.
    Braeuer, T.
    Geiger, B.
    Fuchert, G.
    Bozhenkov, S.
    Pasch, E.
    Grulke, O.
    Kunkel, F.
    Killer, C.
    Nicolai, D.
    Satheeswaran, G.
    Hollfeld, K. P.
    Schweer, B.
    Krings, T.
    Drews, P.
    Offermanns, G.
    Pavone, A.
    Svensson, J.
    Alonso, J. A.
    Burhenn, R.
    Wolf, R. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [34] Localized phase contrast imaging at the Wendelstein 7-X stellarator
    Hansen, S. K.
    Porkolab, M.
    Baehner, J. -P
    Stechow, A. von
    Grulke, O.
    Edlund, E. M.
    PHYSICS OF PLASMAS, 2024, 31 (06)
  • [35] Overdense plasma heating in Wendelstein 7-X(W7-X) stellarator
    Adlparvar, S.
    Miraboutalebi, S.
    Kiai, S. M. Sadat
    Rajaee, L.
    RESULTS IN PHYSICS, 2017, 7 : 1965 - 1970
  • [36] Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator
    Koenig, R.
    Cantarini, J.
    Dreier, H.
    Erckmann, V.
    Hildebrandt, D.
    Hirsch, M.
    Kocsis, G.
    Kornejew, P.
    Laux, M.
    Laqua, H.
    Pasch, E.
    Recsei, S.
    Szabo, V.
    Thomsen, H.
    Weller, A.
    Werner, A.
    Wolf, R.
    Ye, M. Y.
    Zoletnik, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [37] Fast ion loss diagnostic for the Wendelstein 7-X stellarator
    Werner, A
    Darrow, DS
    Kuduk, R
    Weller, A
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 137 - 140
  • [38] Observation of Marfes in the Wendelstein 7-X stellarator with inboard limiters
    Wenzel, U.
    Biedermann, C.
    Kocsis, G.
    Szepesi, T.
    Blackwell, B. D.
    Klose, S.
    Knauer, J.
    Krychowiak, M.
    Stephey, L.
    Schmitz, O.
    Harris, J.
    Koenig, R.
    Pedersen, T. S.
    NUCLEAR FUSION, 2018, 58 (09)
  • [39] Test of Superconducting Coils for the Wendelstein 7-X Stellarator Experiment
    Hertel, K.
    Viebke, H.
    Heenemann, C.
    Baldzuhn, J.
    Ehmler, H.
    Croari, G.
    Bensouda-Korachi, M.
    Genini, L.
    Renard, B.
    Vieillard, L.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 534 - 537
  • [40] Gyrokinetic analysis of linear microinstabilities for the stellarator Wendelstein 7-X
    Xanthopoulos, P.
    Jenko, F.
    PHYSICS OF PLASMAS, 2007, 14 (04)