Determination of poloidal mode numbers of MHD modes and their radial location using a soft x-ray camera array in the Wendelstein 7-X stellarator

被引:5
|
作者
Dreval, M. B. [1 ]
Brandt, C. [2 ]
Schilling, J. [2 ]
Thomsen, H. [2 ]
Beletskii, A. [1 ,3 ]
Koenies, A. [2 ]
机构
[1] Kharkov Inst Phys & Technol, Inst Plasma Phys, Natl Sci Ctr, UA-61108 Kharkov, Ukraine
[2] Max Planck Inst Plasma Phys, Wendelsteinstr 1, D-17491 Greifswald, Germany
[3] Max Planck Inst Mikrostukturphys, Weinberg 2, D-06120 Halle, Germany
关键词
Wendelstein; 7-X; MHD modes; soft x-ray diagnostics;
D O I
10.1088/1361-6587/abf449
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A forward modeling technique is developed for determining the characteristic features of observed MHD modes from the line-of-sight data of the soft x-ray (SXR) tomography diagnostics in the Wendelstein 7-X (W7-X) stellarator. In particular, forward modeling is used to evaluate the poloidal mode numbers m, radial location, poloidal rotation direction and ballooning character of the MHD modes. The poloidal mode structures have been modeled by the radially localized Gaussian-shaped emission regions rotating along the magnetic surfaces. In the present study the cases of rigid-shape emission regions and flexible emission regions are modeled. Various mode phase velocity dependences on the magnetic surface position are simulated. The modeled phase dynamics of line-integrated oscillations and the distribution of oscillation amplitudes are compared with the experimental signals of the SXR cameras which observe the plasma at various viewing angles in the poloidal cross-section. Application of this technique enables describing of the 1-50 kHz modes. In particular, in the discharge W7X-PID 20180918.045 three identified branches with the poloidal mode numbers m= 8, m= 10 and m= 11 localized at rho approximate to 0.3 are rotating in the clockwise poloidal direction. The present paper reports the first application of the forward modeling technique to the data from the SXR diagnostics in W7-X. The high m-modes are identified by forward modeling in W7-X.
引用
收藏
页数:10
相关论文
共 15 条
  • [1] Soft x-ray tomography measurements in the Wendelstein 7-X stellarator
    Brandt, C.
    Schilling, J.
    Thomsen, H.
    Broszat, T.
    Laube, R.
    Schroeder, T.
    Andreeva, T.
    Beurskens, M. N. A.
    Bozhenkov, S. A.
    Brunner, K. J.
    Card, A.
    Cordes, C.
    Damm, H.
    Fuchert, G.
    Gallowski, K.
    Gutzmann, R.
    Knauer, J.
    Laqua, H. P.
    Marquardt, M.
    Nelde, Ph
    Neuner, U.
    Pasch, E.
    Rahbarnia, K.
    Recknagel, J.
    Schuelke, M.
    Scott, E. R.
    Sieber, T.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2020, 62 (03)
  • [2] Installation of the soft X-ray multi-camera tomography system (XMCTS) in the Wendelstein 7-X stellarator
    Brandt, C.
    Broszat, T.
    Thomsen, H.
    Laube, R.
    Marquardt, M.
    Franz, P.
    Schuelke, M.
    Sieber, T.
    Weissflog, S.
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 887 - 891
  • [3] Technology development of the soft X-ray tomography system in Wendelstein 7-X stellarator
    Schuelke, M.
    Cardella, A.
    Hathiramani, D.
    Mettchen, S.
    Thomsen, H.
    Weissflog, S.
    Zacharias, D.
    FUSION ENGINEERING AND DESIGN, 2013, 88 (9-10) : 1987 - 1991
  • [4] Soft x-ray tomograms are consistent with the magneto-hydrodynamic equilibrium in the Wendelstein 7-X stellarator
    Schilling, Jonathan
    Thomsen, Henning
    Brandt, Christian
    Kwak, Sehyun
    Svensson, Jakob
    PLASMA PHYSICS AND CONTROLLED FUSION, 2021, 63 (05)
  • [5] X-ray multi camera tomography system of Wendelstein 7-X
    Klose, S
    Weller, A
    Schötz, P
    Werner, A
    Greve, H
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 229 - 232
  • [6] Comparison of fast tomographic methods for application on the Soft X-ray Tomography System on Wendelstein 7-X stellarator
    Carvalho, P. J.
    Thomsen, H.
    Gori, S.
    Toussaint, U. V.
    Geiger, J.
    Weller, A.
    Coelho, R.
    Fernandes, H.
    PLASMA 2007, 2008, 993 : 167 - +
  • [7] First Results from the Soft X-ray Pulse Height Analysis System on Wendelstein 7-X Stellarator
    Kubkowska, Monika
    Czarnecka, Agata
    Fornal, Tomasz
    Gruca, Marta
    Krawczyk, Natalia
    Jablonski, Slawomir
    Ryc, Leszek
    Thomsen, Henning
    McCarthy, Kieran J.
    Biedermann, Christoph
    Buttenschoen, Birger
    Alonso, Arturo
    Burhenn, Rainer
    FUSION ENGINEERING AND DESIGN, 2018, 136 : 58 - 62
  • [8] Theoretical interpretation of W soft X-ray spectra collected by the pulse height analysis system on Wendelstein 7-X stellarator
    Syrocki, L.
    Kubkowska, M.
    Jablonski, S.
    Neuner, U.
    PHYSICS OF PLASMAS, 2024, 31 (06)
  • [9] Prospects of X-ray imaging spectrometers for impurity transport: Recent results from the stellarator Wendelstein 7-X (invited)
    Langenberg, A.
    Pablant, N. A.
    Wegner, Th
    Traverso, P.
    Marchuk, O.
    Braeuer, T.
    Geiger, B.
    Fuchert, G.
    Bozhenkov, S.
    Pasch, E.
    Grulke, O.
    Kunkel, F.
    Killer, C.
    Nicolai, D.
    Satheeswaran, G.
    Hollfeld, K. P.
    Schweer, B.
    Krings, T.
    Drews, P.
    Offermanns, G.
    Pavone, A.
    Svensson, J.
    Alonso, J. A.
    Burhenn, R.
    Wolf, R. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [10] Determination of MHD mode structures using soft x-ray diagnostics in TCV
    Dreval, M. B.
    Sharapov, S. E.
    Vallar, M.
    Labit, B.
    Karpushov, A. N.
    Garcia-Munoz, M.
    TCV Team
    PLASMA PHYSICS AND CONTROLLED FUSION, 2023, 65 (03)