Prospects of X-ray imaging spectrometers for impurity transport: Recent results from the stellarator Wendelstein 7-X (invited)

被引:37
|
作者
Langenberg, A. [1 ]
Pablant, N. A. [2 ]
Wegner, Th [1 ]
Traverso, P. [3 ]
Marchuk, O. [4 ]
Braeuer, T. [1 ]
Geiger, B. [1 ]
Fuchert, G. [1 ]
Bozhenkov, S. [1 ]
Pasch, E. [1 ]
Grulke, O. [1 ,4 ]
Kunkel, F. [1 ]
Killer, C. [1 ]
Nicolai, D. [5 ]
Satheeswaran, G. [5 ]
Hollfeld, K. P. [5 ]
Schweer, B. [5 ]
Krings, T. [5 ]
Drews, P. [5 ]
Offermanns, G. [5 ]
Pavone, A. [1 ]
Svensson, J. [1 ]
Alonso, J. A. [6 ]
Burhenn, R. [1 ]
Wolf, R. C. [1 ]
机构
[1] Max Planck Inst Plasma Phys, D-17491 Greifswald, Germany
[2] Princeton Plasma Phys Lab, POB 451, Princeton, NJ 08543 USA
[3] Auburn Univ, Auburn, AL 36849 USA
[4] Tech Univ Denmark DTU, Dept Phys, PPFE, DK-2800 Lyngby, Denmark
[5] Forschungszentrum Julich, Inst Energie & Klimaforsch Plasmaphys, D-52425 Julich, Germany
[6] Asociac EURATOM CIEMAT, Lab Nacl Fus, Madrid, Spain
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 10期
关键词
PLASMAS; ARGON;
D O I
10.1063/1.5036536
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports on the design and the performance of the recently upgraded X-ray imaging spectrometer systems, X-ray imaging crystal spectrometer and high resolution X-ray imaging spectrometer, installed at the optimized stellarator Wendelstein 7-X. High resolution spectra of highly ionized, He-like Si, Ar, Ti, and Fe as well as H-like Ar have been observed. A cross comparison of ion and electron temperature profiles derived from a spectral fit and tomographic inversion of Ar and Fe spectra shows a reasonable match with both the spectrometers. The also measured impurity density profiles of Ar and Fe have peaked densities at radial positions that are in qualitative agreement with the expectations from the He-like impurity fractional abundances, given the measured temperature profiles. Repeated measurements of impurity decay times have been demonstrated with an accuracy of 1 ms via injection of non-recycling Ti, Fe, and Mo impurities using a laser blow-off system.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Impurity transport studies at Wendelstein 7-X by means of x-ray imaging spectrometer measurements
    Langenberg, A.
    Warmer, F.
    Fuchert, G.
    Marchuk, O.
    Dinklage, A.
    Wegner, Th
    Alonso, J. A.
    Bozhenkov, S.
    Brunner, J.
    Burhenn, R.
    Buttenschoen, B.
    Drews, P.
    Geiger, B.
    Grulke, O.
    Hirsch, M.
    Hoefel, U.
    Hollfeld, K. P.
    Killer, C.
    Knauer, J.
    Krings, T.
    Kunkel, F.
    Neuner, U.
    Offermanns, G.
    Pablant, N. A.
    Pasch, E.
    Rahbarnia, K.
    Satheeswaran, G.
    Schilling, J.
    Schweer, B.
    Thomsen, H.
    Traverso, P.
    Wolf, R. C.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2019, 61 (01)
  • [2] Soft x-ray tomography measurements in the Wendelstein 7-X stellarator
    Brandt, C.
    Schilling, J.
    Thomsen, H.
    Broszat, T.
    Laube, R.
    Schroeder, T.
    Andreeva, T.
    Beurskens, M. N. A.
    Bozhenkov, S. A.
    Brunner, K. J.
    Card, A.
    Cordes, C.
    Damm, H.
    Fuchert, G.
    Gallowski, K.
    Gutzmann, R.
    Knauer, J.
    Laqua, H. P.
    Marquardt, M.
    Nelde, Ph
    Neuner, U.
    Pasch, E.
    Rahbarnia, K.
    Recknagel, J.
    Schuelke, M.
    Scott, E. R.
    Sieber, T.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2020, 62 (03)
  • [3] Argon impurity transport studies at Wendelstein 7-X using x-ray imaging spectrometer measurements
    Langenberg, A.
    Pablant, N. A.
    Marchuk, O.
    Zhang, D.
    Alonso, J. A.
    Burhenn, R.
    Svensson, J.
    Valson, P.
    Gates, D.
    Beurskens, M.
    Wolf, R. C.
    NUCLEAR FUSION, 2017, 57 (08)
  • [4] The Wendelstein 7-X Stellarator
    Wagner, F
    Milch, I
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2005, 50 (8-9): : 519 - +
  • [5] First Results from the Soft X-ray Pulse Height Analysis System on Wendelstein 7-X Stellarator
    Kubkowska, Monika
    Czarnecka, Agata
    Fornal, Tomasz
    Gruca, Marta
    Krawczyk, Natalia
    Jablonski, Slawomir
    Ryc, Leszek
    Thomsen, Henning
    McCarthy, Kieran J.
    Biedermann, Christoph
    Buttenschoen, Birger
    Alonso, Arturo
    Burhenn, Rainer
    FUSION ENGINEERING AND DESIGN, 2018, 136 : 58 - 62
  • [6] Technology development of the soft X-ray tomography system in Wendelstein 7-X stellarator
    Schuelke, M.
    Cardella, A.
    Hathiramani, D.
    Mettchen, S.
    Thomsen, H.
    Weissflog, S.
    Zacharias, D.
    FUSION ENGINEERING AND DESIGN, 2013, 88 (9-10) : 1987 - 1991
  • [7] Test results from the Wendelstein 7-X stellarator demonstration coil
    Heller, R
    Maurer, W
    Sapper, J
    Schauer, F
    Schönewolf, I
    Ulbricht, A
    Wüchner, F
    Zahn, G
    CRYOGENICS, 2000, 40 (8-10) : 561 - 567
  • [8] Localized phase contrast imaging at the Wendelstein 7-X stellarator
    Hansen, S. K.
    Porkolab, M.
    Baehner, J. -P
    Stechow, A. von
    Grulke, O.
    Edlund, E. M.
    PHYSICS OF PLASMAS, 2024, 31 (06)
  • [9] Concepts of x-ray diagnostics for WENDELSTEIN 7-X
    Weller, A
    Mohr, S
    Junghans, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3962 - 3965
  • [10] Neutron diagnostics at the Wendelstein 7-X stellarator
    Schneider, W.
    Wiegel, B.
    Gruenauer, F.
    Burhenn, R.
    Koch, S.
    Schuhmacher, H.
    Zimbal, A.
    JOURNAL OF INSTRUMENTATION, 2012, 7