Soft x-ray tomography measurements in the Wendelstein 7-X stellarator

被引:25
|
作者
Brandt, C. [1 ]
Schilling, J. [1 ]
Thomsen, H. [1 ]
Broszat, T. [1 ]
Laube, R. [1 ]
Schroeder, T. [1 ]
Andreeva, T. [1 ]
Beurskens, M. N. A. [1 ]
Bozhenkov, S. A. [1 ]
Brunner, K. J. [1 ]
Card, A. [1 ]
Cordes, C. [1 ]
Damm, H. [1 ]
Fuchert, G. [1 ]
Gallowski, K. [1 ]
Gutzmann, R. [1 ]
Knauer, J. [1 ]
Laqua, H. P. [1 ]
Marquardt, M. [1 ]
Nelde, Ph [1 ]
Neuner, U. [1 ]
Pasch, E. [1 ]
Rahbarnia, K. [1 ]
Recknagel, J. [1 ]
Schuelke, M. [1 ]
Scott, E. R. [1 ]
Sieber, T. [1 ]
机构
[1] Max Planck Inst Plasma Phys, Wendelsteinstr 1, D-17491 Greifswald, Germany
关键词
x-ray; tomography; XMCTS; stellarator; Wendelstein; W7-X; DIAGNOSTICS;
D O I
10.1088/1361-6587/ab630d
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The soft x-ray tomography diagnostic in the stellarator Wendelstein 7-X consists of twenty pinhole cameras, up-down symmetrically arranged in a poloidal, triangular cross-section of the plasma vessel. The x-ray emissivity is measured with 16 bit amplitude resolution at 2 MHz sampling rate along 360 lines-of-sight by silicon photodiode arrays. In the recent operation campaign data acquisition (DAQ) has been working reliable for the conducted plasma pulse lengths <1 min, however the DAQ system are ready for the foreseen 30 min plasma pulse lengths of upcoming campaigns. The bandwidth of the preamplifiers is 200 kHz and the sensitive energy range is approximately 1-12 keV. The measurements indicate the up-down symmetric emissivity distribution in the triangular poloidal cross-section. First tomographic reconstructions of different magnetic field configurations are consistent with the theoretically calculated flux surface topology.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Construction of Wendelstein 7-X - engineering a steady state stellarator
    Bosch, H. -S.
    Erckmann, V.
    Koenig, R.
    Schauer, F.
    Stadler, R.
    Werner, A.
    2009 23RD IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 2009, : 696 - 702
  • [42] The ECRH-Power Upgrade at the Wendelstein 7-X Stellarator
    Laqua, H. P.
    Avramidis, K. A.
    Braune, H.
    Chelis, I.
    Gantenbein, G.
    Illy, S.
    Ioannidis, Z.
    Jelonnek, J.
    Jin, J.
    Krier, L.
    Lechte, C.
    Leggieri, A.
    Legrand, F.
    Marsen, S.
    Moseev, D.
    Oosterbeek, H.
    Rzesnicki, T.
    Ruess, T.
    Stange, T.
    Thumm, M.
    Tigelis, I.
    Wolf, R. C.
    21ST JOINT WORKSHOP ON ELECTRON CYCLOTRON EMISSION AND ELECTRON CYCLOTRON RESONANCE HEATING, EC21, 2023, 277
  • [43] Pressure surge in Wendelstein 7-X experimental stellarator facility
    Kaliatka, A.
    Uspuras, E.
    Kaliatka, T.
    KERNTECHNIK, 2012, 77 (02) : 134 - 140
  • [44] A divertor scraper observation system for the Wendelstein 7-X stellarator
    Wurden, G. A.
    Fellinger, J.
    Biedermann, C.
    Drewelow, P.
    Ford, O.
    Gamradt, M.
    Greve, H.
    Herold, F.
    Jakubowski, M.
    Jenzsch, H.
    Niemann, H.
    Sitjes, A. Puig
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [45] A stellarator reactor based on the optimization criteria of Wendelstein 7-X
    Wolf, R. C.
    FUSION ENGINEERING AND DESIGN, 2008, 83 (7-9) : 990 - 996
  • [46] Investigation of TESPEL cloud dynamics in Wendelstein 7-X stellarator
    Kocsis, G.
    Tamura, N.
    Bussiahn, R.
    McCarthy, K. J.
    Baldzuhn, J.
    Biedermann, C.
    Cseh, G.
    Damm, H.
    Kornejew, P.
    Koenig, R.
    Panadero, N.
    Szepesi, T.
    NUCLEAR FUSION, 2021, 61 (01)
  • [47] Structural evaluation of the busbar system of Wendelstein 7-X stellarator
    Giesen, B.
    Panin, A.
    Boguszewski, T.
    Brons, S.
    Charl, A.
    Czymek, G.
    John, A.
    Neubauer, O.
    Sauer, M.
    Schick, R.
    Szagowska, J.
    Wolters, J.
    FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) : 1591 - 1598
  • [48] Argon impurity transport studies at Wendelstein 7-X using x-ray imaging spectrometer measurements
    Langenberg, A.
    Pablant, N. A.
    Marchuk, O.
    Zhang, D.
    Alonso, J. A.
    Burhenn, R.
    Svensson, J.
    Valson, P.
    Gates, D.
    Beurskens, M.
    Wolf, R. C.
    NUCLEAR FUSION, 2017, 57 (08)
  • [49] The Set of Diagnostics for the First Operation Campaign of the Wendelstein 7-X Stellarator
    Koenig, Ralf
    Baldzuhn, J.
    Biel, W.
    Biedermann, C.
    Bosch, H. S.
    Bozhenkov, S.
    Braeuer, T.
    Brotas de Carvalho, B.
    Burhenn, R.
    Buttenschoen, B.
    Cseh, G.
    Czarnecka, A.
    Endler, M.
    Erckmann, V.
    Estrada, T.
    Geiger, J.
    Grulke, O.
    Hartmann, D.
    Hathiramani, D.
    Hirsch, M.
    Onski, S. Jabl
    Jakubowski, M.
    Kaczmarczyk, J.
    Klinger, T.
    Klose, S.
    Kocsis, G.
    Kornejew, P.
    Kraemer-Flecken, A.
    Kremeyer, T.
    Krychowiak, M.
    Kubkowska, M.
    Langenberg, A.
    Laqua, H. P.
    Laux, M.
    Liang, Y.
    Lorenz, A.
    Marchuk, A. O.
    Moncada, V.
    Neubauer, O.
    Neuner, U.
    Oosterbeek, J. W.
    Otte, M.
    Pablant, N.
    Pasch, E.
    Pedersen, T. S.
    Rahbarnia, K.
    Ryc, L.
    Schmitz, O.
    Schneider, W.
    Schuhmacher, H.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [50] Neutral particle modelling and particle exhaust in the Wendelstein 7-X stellarator
    Grote, H
    Kisslinger, J
    Renner, H
    Boscary, J
    Greuner, H
    Hoffmann, FW
    Mendelevitch, B
    JOURNAL OF NUCLEAR MATERIALS, 2003, 313 : 1298 - 1303