Dispersed Hydrogel Actuator for Modiolar Hugging Cochlear Implant Electrode Arrays

被引:4
|
作者
Stieghorst, J. [1 ,2 ]
Doll, T. [1 ,2 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol, D-30625 Hannover, Germany
[2] Hearing4all, Cluster Excellence, D-30625 Hannover, Germany
关键词
Cochlear implants (CIs); electrode carrier; hydrogel actuation; modiolar coiling electrode; modiolar hugging electrode; FILLER; BIOCOMPATIBILITY;
D O I
10.1109/TBME.2016.2524663
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Cochlear implants are used in patients with profound deafness due to degeneration of hair cells inside the cochlea. As improvement for commercially available CIs with straight electrode arrays, it is desired that the electrode array hugs toward the nerve cells located at the central axis of the cochlea in order to reduce the stimulation distance. Therefore, we present a hydrogel-based actuated electrode shaft, which should bend itself when exposed to saline solution (simulating the intracochlear liquid perilymph). Methods: In vitro tests with the electrode arrays were performed in a cochlea model. Different quantities and grain sizes of the hydrogel-building polymer (polyacrylamide) were used to study the self-bending effect. Furthermore, material interfaces between the components were evaluated with scanning electron microscopy, fluorescence microscopy, and an adapted tape test according to DIN EN ISO 2409. Results: Self-bending of the electrode array was observed in the cochlea model and a maximum number of 3.1 turns was achieved. No delamination between the components could be observed. Conclusion: After insertion, we expect that the electrode shaft moves into a patient individual perimodiolar position without losing its functionality because of a delamination of the components. Significance: A modiolar hugging electrode design is presented, which may improve hearing restauration with cochlear implants due to an easier insertion technique and a patient individualized hugging to the modiolus.
引用
收藏
页码:2294 / 2300
页数:7
相关论文
共 50 条
  • [41] MULTIPLE ELECTRODE COCHLEAR IMPLANT
    CLARK, GM
    TONG, YC
    BLACK, R
    FORSTER, IC
    PATRICK, JF
    DEWHURST, DJ
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1977, 91 (11): : 935 - 945
  • [42] Cochlear implantation with Slim Modiolar Electrode carriers enables hearing preservation
    Sakmen, Kenan Dennis
    Issing, Christian
    Vazzana, Caterina
    Weissgerber, Tobias
    Linke, Albrecht
    Stoever, Timo
    Helbig, Silke
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2025,
  • [43] Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size, and depth of insertion
    Rebscher, Stephen J.
    Hetherington, Alexander
    Bonham, Ben
    Wardrop, Peter
    Whinney, David
    Leake, Patricia A.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2008, 45 (05): : 731 - 747
  • [44] Cochlear coverage with lateral wall cochlear implant electrode arrays affects post-operative speech recognition
    Weller, Tobias
    Timm, Max Eike
    Lenarz, Thomas
    Buechner, Andreas
    PLOS ONE, 2023, 18 (07):
  • [45] Hydraulic insertions of cochlear implant electrode arrays into the human cadaver cochlea: preliminary findings
    M. Geraldine Zuniga
    Thomas Lenarz
    Thomas S. Rau
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 2827 - 2835
  • [46] Hydraulic insertions of cochlear implant electrode arrays into the human cadaver cochlea: preliminary findings
    Geraldine, M.
    Lenarz, Thomas
    Rau, Thomas S.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (06) : 2827 - 2835
  • [47] A method for accurate and reproducible specimen alignment for insertion tests of cochlear implant electrode arrays
    Cramer, Jakob
    Boettcher-Rebmann, Georg
    Lenarz, Thomas
    Rau, Thomas S.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (09) : 1883 - 1893
  • [48] Preoperative prediction of angular insertion depth of lateral wall cochlear implant electrode arrays
    Khan, Mohammad M. R.
    Labadie, Robert F.
    Noble, Jack H.
    JOURNAL OF MEDICAL IMAGING, 2020, 7 (03)
  • [49] Optimal Path Planning for Robotic Insertion of Steerable Electrode Arrays in Cochlear Implant Surgery
    Zhang, Jian
    Roland, J. Thomas, Jr.
    Manolidis, Spiros
    Simaan, Nabil
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2009, 3 (01):
  • [50] Preservation of Residual Hearing After Cochlear Implant Surgery With Deep Insertion Electrode Arrays
    Sierra, Cristina
    Calderon, Manuela
    Barcena, Eduardo
    Tisaire, Alexandra
    Raboso, Eduardo
    OTOLOGY & NEUROTOLOGY, 2019, 40 (04) : E373 - E380