Dispersed Hydrogel Actuator for Modiolar Hugging Cochlear Implant Electrode Arrays

被引:4
|
作者
Stieghorst, J. [1 ,2 ]
Doll, T. [1 ,2 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol, D-30625 Hannover, Germany
[2] Hearing4all, Cluster Excellence, D-30625 Hannover, Germany
关键词
Cochlear implants (CIs); electrode carrier; hydrogel actuation; modiolar coiling electrode; modiolar hugging electrode; FILLER; BIOCOMPATIBILITY;
D O I
10.1109/TBME.2016.2524663
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Cochlear implants are used in patients with profound deafness due to degeneration of hair cells inside the cochlea. As improvement for commercially available CIs with straight electrode arrays, it is desired that the electrode array hugs toward the nerve cells located at the central axis of the cochlea in order to reduce the stimulation distance. Therefore, we present a hydrogel-based actuated electrode shaft, which should bend itself when exposed to saline solution (simulating the intracochlear liquid perilymph). Methods: In vitro tests with the electrode arrays were performed in a cochlea model. Different quantities and grain sizes of the hydrogel-building polymer (polyacrylamide) were used to study the self-bending effect. Furthermore, material interfaces between the components were evaluated with scanning electron microscopy, fluorescence microscopy, and an adapted tape test according to DIN EN ISO 2409. Results: Self-bending of the electrode array was observed in the cochlea model and a maximum number of 3.1 turns was achieved. No delamination between the components could be observed. Conclusion: After insertion, we expect that the electrode shaft moves into a patient individual perimodiolar position without losing its functionality because of a delamination of the components. Significance: A modiolar hugging electrode design is presented, which may improve hearing restauration with cochlear implants due to an easier insertion technique and a patient individualized hugging to the modiolus.
引用
收藏
页码:2294 / 2300
页数:7
相关论文
共 50 条
  • [21] Development and Characterizaion of a Micromagnetic Alternative to Cochlear Implant Electrode Arrays
    Sarreal, Ressa Reneth S.
    Blake, David T.
    Bhatti, Pamela T.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2022, 30 : 2116 - 2125
  • [22] Effects of Insertion Depth and Modiolar Proximity on Cochlear Implant Speech Recognition Outcomes With a Precurved Electrode Array
    Canfarotta, Michael W.
    Dillon, Margaret T.
    Thompson, Nicholas J.
    Selleck, A. Morgan
    Dedmon, Matthew M.
    Brown, Kevin D.
    OTOLOGY & NEUROTOLOGY, 2025, 46 (03) : 272 - 278
  • [23] Electrode Interaction in Cochlear Implant Recipients: Comparison of Straight and Contour Electrode Arrays
    Xi, Xin
    Ji, Fei
    Han, Dongyi
    Hong, Mengdi
    Chen, Aiting
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2009, 71 (04): : 228 - 237
  • [24] In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays
    Ketten, DR
    Vannier, MW
    Skinner, MW
    Gates, GA
    Wang, G
    Neely, JG
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1998, 107 (11): : 1 - 16
  • [25] Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays
    Ramos de Miguel, Angel
    Argudo, Andrea A.
    Borkoski Barreiro, Silvia A.
    Falcon Gonzalez, Juan Carlos
    Ramos Macias, Angel
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (06) : 1385 - 1394
  • [26] Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays
    Ángel Ramos de Miguel
    Andrea A. Argudo
    Silvia A. Borkoski Barreiro
    Juan Carlos Falcón González
    Angel Ramos Macías
    European Archives of Oto-Rhino-Laryngology, 2018, 275 : 1385 - 1394
  • [27] Hearing preservation with a slim modiolar cochlear implant in a pediatric cohort
    Jimenez, Joaquin E.
    Govil, Nandini
    Shaffer, Amber D.
    Ledonne, Jessica C.
    Chi, David H.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2021, 140
  • [28] Transimpedance Matrix Measurement (TIM) Parameters Evaluation for the Assessment of Cochlear Implant Electrode Placement and Modiolar Proximity in Children
    Radomska, Katarzyna
    Talar, Marcin
    Haber, Karolina
    Mierzwinska-Dolny, Paulina
    Fishman, Andrew J.
    Mierzwinski, Jozef
    BIOMEDICINES, 2025, 13 (02)
  • [29] Micro- and Nano-patterned Cochlear Implant Electrode Arrays
    Paasche, G.
    Fadeeva, E.
    Linke, I.
    Chichkov, B.
    Lenarz, T.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S78 - S78
  • [30] COCHLEAR IMPLANT ELECTRODE
    CLARK, GM
    HALLWORTH, RJ
    ZDANIUS, K
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1975, 89 (08): : 787 - 792