Biomechanical Evaluation of a Novel Loop Retention Mechanism for Cortical Graft Fixation in ACL Reconstruction

被引:3
|
作者
Gotschi, Tobias [1 ,2 ,3 ]
Rosenberg, George [1 ,2 ]
Li, Xiang [1 ,2 ]
Zhang, Chen [1 ,2 ,4 ]
Bachmann, Elias [1 ,2 ,3 ]
Snedeker, Jess G. [1 ,2 ,3 ]
Fucentese, Sandro F. [1 ,3 ]
机构
[1] Balgrist Univ Hosp, Forchstr 340, CH-8008 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomech, Zurich, Switzerland
[3] Balgrist Univ Hosp, Dept Orthoped, Zurich, Switzerland
[4] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Orthoped, Xian, Peoples R China
关键词
ACL reconstruction; cortical fixation; adjustable button; biomechanical testing; cyclic loading; ANTERIOR CRUCIATE LIGAMENT; ADJUSTABLE-LENGTH LOOP; IMPROVE SUTURE PULLOUT; SUSPENSION DEVICES; FIXED-LOOP; TENDON; FORCES; TUNNEL; MODEL; KNEE;
D O I
10.1177/2325967120904322
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Implant fixation by means of a cortical fixation device (CFD) has become a routine procedure in anterior cruciate ligament reconstruction. There is no clear consensus whether adjustable-length CFDs are more susceptible to loop lengthening when compared with pretied fixed-length CFDs. Purpose: To assess biomechanical performance measures of 3 types of CFDs when subjected to various loading protocols. Study Design: Controlled laboratory study. Methods: Three types of CFDs underwent biomechanical testing: 1 fixed length and 2 adjustable length. One of the adjustable-length devices is based on the so-called finger trap mechanism, and the other is based on a modified sling lock mechanism. A device-only test of 5000 cycles (n = 8 per group) and a tendon-device test of 1000 cycles (n = 8 per group) with lower and upper force limits of 50 and 250 N, respectively, were applied, followed by ramp-to-failure testing. Adjustable-length devices then underwent further cyclic testing with complete loop unloading (n = 5 per group) at each cycle, as well as fatigue testing (n = 3 per group) over a total of 1 million cycles. Derived mechanical parameters were compared among the devices for statistical significance using Kruskal-Wallis analysis of variance followed by post hoc Mann-Whitney U testing with Bonferroni correction. Results: All CFDs showed elongation <2 mm after 5000 cycles when tested in an isolated manner and withstood ultimate tensile forces in excess of estimated peak in vivo forces. In both device-only and tendon-device tests, differences in cyclic performance were found among the devices, favoring adjustable-length fixation devices over the fixed-length device. Completely unloading the suspension loops, however, led to excessive loop lengthening of the finger trap device, whereas the modified sling lock device remained stable throughout the test. The fixed-length device displayed superior ultimate strength over both adjustable-length devices. Both adjustable-length devices showed adequate fatigue behavior during high-cyclic testing. Conclusion: All tested devices successfully prevented critical construct elongation when tested with constant tension and withstood ultimate loads in excess of estimated in vivo forces during the rehabilitation phase. The finger trap device gradually lengthened excessively when completely unloaded during cyclic testing.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] ACL reconstruction with adjustable-length loop cortical button fixation results in less tibial tunnel widening compared with interference screw fixation
    Mayr, Raul
    Smekal, Vinzenz
    Koidl, Christian
    Coppola, Christian
    Eichinger, Martin
    Rudisch, Ansgar
    Kranewitter, Christof
    Attal, Rene
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (04) : 1036 - 1044
  • [42] Similar biomechanical properties of four tripled tendon graft models for ACL reconstruction
    Davide Pavan
    Federica Morello
    Francesco Monachino
    Giuseppe Rovere
    Lawrence Camarda
    Giuseppe Pitarresi
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 1155 - 1165
  • [43] Similar biomechanical properties of four tripled tendon graft models for ACL reconstruction
    Pavan, Davide
    Morello, Federica
    Monachino, Francesco
    Rovere, Giuseppe
    Camarda, Lawrence
    Pitarresi, Giuseppe
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (06) : 1155 - 1165
  • [44] BIOMECHANICAL EVALUATION OF AN INVERTED FIXATION FOR ACL RECONSTRUCTION WITH NONMETALLIC HARDWARE AND TIBIAL SUBCORTICAL SUPPORT TO INCREASE STRENGTH AT THE TIBIAL SITE
    PRADO-NOVOA, M. A. R. I. A.
    TRABALON, A. L. E. J. A. N. D. R. O. P. E. N. A.
    MORENO-VEGAS, S. A. L. V. A. D. O. R.
    CAMPOS, M. B. E. L. E. N. E. S. T. E. B. A. N. E. Z.
    ESPEJO-REINA, A. L. E. J. A. N. D. R. O.
    PEREZ-BLANCA, A. N. A.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (10)
  • [45] FEMORAL MECHANICAL-BIOLOGICAL GRAFT FIXATION IN ACL RECONSTRUCTION IN YOUNG PATIENTS
    Gomes, Joao Ellera
    Konrath, Cassio Alves
    CLINICS, 2010, 65 (03) : 347 - 349
  • [46] Evaluation of Tibial Fixation Devices for Quadrupled Hamstring ACL Reconstruction
    Ammann, Elias
    Hecker, Andreas
    Bachmann, Elias
    Snedeker, Jess G.
    Fucentese, Sandro F.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (05)
  • [47] Evolgate fixation of doubled flexor graft in anterior cruciate ligament reconstruction - Biomechanical evaluation with cyclic loading
    Ferretti, A
    Conteduca, F
    Labianca, L
    Monaco, E
    De Carli, A
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (04): : 574 - 582
  • [48] Adjustable buttons for ACL graft cortical fixation partially fail with cyclic loading and unloading
    Glasbrenner, J.
    Domnick, C.
    Raschke, M. J.
    Willinghoefer, T.
    Kittl, C.
    Michel, P.
    Waehnert, D.
    Herbort, Mirco
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (08) : 2530 - 2536
  • [49] Adjustable buttons for ACL graft cortical fixation partially fail with cyclic loading and unloading
    J. Glasbrenner
    C. Domnick
    M. J. Raschke
    T. Willinghöfer
    C. Kittl
    P. Michel
    D. Wähnert
    Mirco Herbort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 2530 - 2536
  • [50] OPTIMAL GRAFT FIXATION - THE EFFECT OF GAP SIZE AND SCREW SIZE ON BONE PLUG FIXATION IN ACL RECONSTRUCTION
    BUTLER, JC
    BRANCH, TP
    HUTTON, WC
    ARTHROSCOPY, 1994, 10 (05): : 524 - 529