Biomechanical Evaluation of a Novel Loop Retention Mechanism for Cortical Graft Fixation in ACL Reconstruction

被引:3
|
作者
Gotschi, Tobias [1 ,2 ,3 ]
Rosenberg, George [1 ,2 ]
Li, Xiang [1 ,2 ]
Zhang, Chen [1 ,2 ,4 ]
Bachmann, Elias [1 ,2 ,3 ]
Snedeker, Jess G. [1 ,2 ,3 ]
Fucentese, Sandro F. [1 ,3 ]
机构
[1] Balgrist Univ Hosp, Forchstr 340, CH-8008 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomech, Zurich, Switzerland
[3] Balgrist Univ Hosp, Dept Orthoped, Zurich, Switzerland
[4] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Orthoped, Xian, Peoples R China
关键词
ACL reconstruction; cortical fixation; adjustable button; biomechanical testing; cyclic loading; ANTERIOR CRUCIATE LIGAMENT; ADJUSTABLE-LENGTH LOOP; IMPROVE SUTURE PULLOUT; SUSPENSION DEVICES; FIXED-LOOP; TENDON; FORCES; TUNNEL; MODEL; KNEE;
D O I
10.1177/2325967120904322
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Implant fixation by means of a cortical fixation device (CFD) has become a routine procedure in anterior cruciate ligament reconstruction. There is no clear consensus whether adjustable-length CFDs are more susceptible to loop lengthening when compared with pretied fixed-length CFDs. Purpose: To assess biomechanical performance measures of 3 types of CFDs when subjected to various loading protocols. Study Design: Controlled laboratory study. Methods: Three types of CFDs underwent biomechanical testing: 1 fixed length and 2 adjustable length. One of the adjustable-length devices is based on the so-called finger trap mechanism, and the other is based on a modified sling lock mechanism. A device-only test of 5000 cycles (n = 8 per group) and a tendon-device test of 1000 cycles (n = 8 per group) with lower and upper force limits of 50 and 250 N, respectively, were applied, followed by ramp-to-failure testing. Adjustable-length devices then underwent further cyclic testing with complete loop unloading (n = 5 per group) at each cycle, as well as fatigue testing (n = 3 per group) over a total of 1 million cycles. Derived mechanical parameters were compared among the devices for statistical significance using Kruskal-Wallis analysis of variance followed by post hoc Mann-Whitney U testing with Bonferroni correction. Results: All CFDs showed elongation <2 mm after 5000 cycles when tested in an isolated manner and withstood ultimate tensile forces in excess of estimated peak in vivo forces. In both device-only and tendon-device tests, differences in cyclic performance were found among the devices, favoring adjustable-length fixation devices over the fixed-length device. Completely unloading the suspension loops, however, led to excessive loop lengthening of the finger trap device, whereas the modified sling lock device remained stable throughout the test. The fixed-length device displayed superior ultimate strength over both adjustable-length devices. Both adjustable-length devices showed adequate fatigue behavior during high-cyclic testing. Conclusion: All tested devices successfully prevented critical construct elongation when tested with constant tension and withstood ultimate loads in excess of estimated in vivo forces during the rehabilitation phase. The finger trap device gradually lengthened excessively when completely unloaded during cyclic testing.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Graft failure versus graft fixation in ACL reconstruction: histological and immunohistochemical studies in rabbits
    Shan-Ling Hsu
    Ching-Jen Wang
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 1197 - 1202
  • [32] Biomechanical Stability of Third-Generation Adjustable Suture Loop Devices Versus Continuous Loop Button Device for Cortical Fixation of ACL Tendon Grafts
    Deichsel, Adrian
    Leibrandt, Lara
    Raschke, Michael J.
    Klimek, Matthias
    Oeckenpoehler, Simon
    Herbst, Elmar
    Kittl, Christoph
    Glasbrenner, Johannes
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2024, 12 (04)
  • [33] Comparative biomechanical study of the Ligament Plate® and other fixation devices in ACL reconstruction
    Jae Ang Sim
    Ji Hoon Kwak
    Sang Hoon Yang
    Beom Koo Lee
    International Orthopaedics, 2009, 33 : 1269 - 1274
  • [34] Comparative biomechanical study of the Ligament Plate® and other fixation devices in ACL reconstruction
    Sim, Jae Ang
    Kwak, Ji Hoon
    Yang, Sang Hoon
    Lee, Beom Koo
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (05) : 1269 - 1274
  • [35] Outcomes of ACL Reconstruction With Fixed Versus Variable Loop Button Fixation
    Wise, Brent T.
    Patel, Nick N.
    Wier, Garrison
    Labib, Sameh A.
    ORTHOPEDICS, 2017, 40 (02) : E275 - E280
  • [36] Quadruple Semitendinosus Graft Construct With Double Cortical Suspensory Fixation for Anterior Cruciate Ligament Reconstruction: A Biomechanical Study
    Madail, Carla Alexandra
    Vaz, Maria de Fatima
    Amaral, Pedro Miguel
    Consciencia, Jose Guimaraes
    Silva, Alcindo Lucas
    SCIENTIFIC REPORTS, 2018, 8
  • [37] Quadruple Semitendinosus Graft Construct With Double Cortical Suspensory Fixation for Anterior Cruciate Ligament Reconstruction: A Biomechanical Study
    Carla Alexandra Madaíl
    Maria de Fátima Vaz
    Pedro Miguel Amaral
    José Guimarães Consciência
    Alcindo Lucas Silva
    Scientific Reports, 8
  • [38] Adjustable- Versus Fixed-Loop Devices for Femoral Fixation in ACL Reconstruction: An In Vitro Full-Construct Biomechanical Study of Surgical Technique-Based Tibial Fixation and Graft Preparation
    Smith, Patrick A.
    Piepenbrink, Marina
    Smith, Shelby K.
    Bachmaier, Samuel
    Bedi, Asheesh
    Wijdicks, Coen A.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (04):
  • [39] Evaluating different closed loop graft preparation technique for tibial suspensory fixation in ACL reconstruction using TightRope (TM)
    Sasho, Takahisa
    Sasaki, Toshihide
    Hoshi, Hiroko
    Akagi, Ryuichiro
    Enomoto, Takahiro
    Sato, Yusuke
    Nakagawa, Ryosuke
    Tahara, Masamichi
    Yamaguchi, Satoshi
    ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY, 2018, 12 : 5 - 11
  • [40] ACL reconstruction with adjustable-length loop cortical button fixation results in less tibial tunnel widening compared with interference screw fixation
    Raul Mayr
    Vinzenz Smekal
    Christian Koidl
    Christian Coppola
    Martin Eichinger
    Ansgar Rudisch
    Christof Kranewitter
    René Attal
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 1036 - 1044