Volumetric ultrasound Imaging using 2-D CMUT arrays

被引:140
|
作者
Oralkan, Ö
Ergun, AS
Cheng, CH
Johnson, JA
Karaman, M
Lee, TH
Khuri-Yakub, BT
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
[2] Stanford Univ, Ctr Integrated Syst, Stanford, CA 94305 USA
[3] Isik Univ, Dept Elect Engn, TR-80670 Istanbul, Turkey
[4] Stanford Univ, Sch Med, Dept Neurosurg, Image Guidance Lab, Stanford, CA 94305 USA
关键词
D O I
10.1109/TUFFC.2003.1251142
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-mum element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 X 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 X 16-element portion of the array to surrounding bondpads. An 8 x 16-element poition of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 X 4 group of elements in the middle of the 8 X 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.
引用
收藏
页码:1581 / 1594
页数:14
相关论文
共 50 条
  • [1] Integrated Circuits for Volumetric Ultrasound Imaging With 2-D CMUT Arrays
    Bhuyan, Anshuman
    Choe, Jung Woo
    Lee, Byung Chul
    Wygant, Ira O.
    Nikoozadeh, Amin
    Oralkan, Omer
    Khuri-Yakub, Butrus T.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (06) : 796 - 804
  • [2] Hybrid Volume Beamforming for 3-D Ultrasound Imaging using 2-D CMUT Arrays
    Kim, Bae-Hyung
    Song, Tai-Kyong
    Yoo, Yangmo
    Chang, Jin Ho
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Song, Jongkeun
    [J]. 2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 2246 - 2249
  • [3] VOLUMETRIC ELASTICITY IMAGING WITH A 2-D CMUT ARRAY
    Fisher, Ted G.
    Hall, Timothy J.
    Panda, Satchi
    Richards, Michael S.
    Barbone, Paul E.
    Jiang, Jingfeng
    Resnick, Jeff
    Barnes, Steve
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (06): : 978 - 990
  • [4] Volumetric ultrasound image-forming using fully controllable 2-D CMUT-on-ASIC arrays
    Kim, Bae-Hyung
    Song, Jongkeun
    Lee, Seunghun
    Cho, Kyungil
    Kim, Youngil
    Jeon, Taeho
    [J]. MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [5] Beamforming and Imageforming for 3D Ultrasound Imaging System using 2-D CMUT-on-ASIC Arrays
    Park, Suhyun
    Kim, Bae-Hyung
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Jeon, Taeho
    Song, Jongkeun
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1440 - 1443
  • [6] Phase-rotation based receive-beamformer for miniaturized volumetric ultrasound imaging scanners using 2-D CMUT-on-ASIC arrays
    Kim, Bae-Hyung
    Lee, Seunghun
    Song, Jongkeun
    Kim, Youngil
    Jeon, Taeho
    Cho, Kyungil
    [J]. MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [7] Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
    Wygant, Ira O.
    Zhuang, Xuefeng
    Yeh, David T.
    Oralkan, Omer
    Ergun, A. Sanli
    Karaman, Mustafa
    Khuri-Yakub, Butrus T.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (02) : 327 - 342
  • [8] Volumetric Ultrasound Imaging with Row-Column Addressed 2-D Arrays Using Spatial Matched Filter Beamforming
    Bouzari, Hamed
    Engholm, Mathias
    Christiansen, Thomas Lehrmann
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. 2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [9] Dual-Mode Integrated Circuit for Imaging and HIFU With 2-D CMUT Arrays
    Jang, Ji Hoon
    Rasmussen, Morten Fischer
    Bhuyan, Anshuman
    Yoon, Hyo-Seon
    Moini, Azadeh
    Chang, Chienliu
    Watkins, Ronald D.
    Choe, Jung Woo
    Nikoozadeh, Amin
    Stephens, Douglas
    Oralkan, Oemer
    Pauly, Kim Butts
    Khuri-Yakub, Butrus
    [J]. 2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [10] HYBRID BEAMFORMATION FOR VOLUMETRIC ULTRASOUND IMAGING SCANNERS USING 2-D ARRAY TRANSDUCERS
    Kim, Bae-Hyung
    Lee, Seungheun
    Kim, Youngil
    Cho, Kyungil
    Kim, Dongwook
    Song, Jongkeun
    [J]. 2012 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2012), 2012, : 2297 - 2300