Volumetric ultrasound Imaging using 2-D CMUT arrays

被引:140
|
作者
Oralkan, Ö
Ergun, AS
Cheng, CH
Johnson, JA
Karaman, M
Lee, TH
Khuri-Yakub, BT
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
[2] Stanford Univ, Ctr Integrated Syst, Stanford, CA 94305 USA
[3] Isik Univ, Dept Elect Engn, TR-80670 Istanbul, Turkey
[4] Stanford Univ, Sch Med, Dept Neurosurg, Image Guidance Lab, Stanford, CA 94305 USA
关键词
D O I
10.1109/TUFFC.2003.1251142
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-mum element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 X 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 X 16-element portion of the array to surrounding bondpads. An 8 x 16-element poition of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 X 4 group of elements in the middle of the 8 X 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.
引用
收藏
页码:1581 / 1594
页数:14
相关论文
共 50 条
  • [21] 3-D ultrasound imaging using forward viewing CMUT ring arrays for intravascular and intracardiac applications
    Yeh, DT
    Oralkan, Ö
    Wygant, IO
    O'Donnell, M
    Khuri-Yakub, BT
    [J]. 2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 783 - 786
  • [22] Annular CMUT arrays for side looking intravascular ultrasound imaging
    Zahorian, Jaime
    Guldiken, Rasim
    Gurun, Gokce
    Qureshi, M. Shakeel
    Balantekin, Mujdat
    Degertekin, F. Levent
    Carlier, Stephane
    Sisman, Alper
    Karaman, Mustafa
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 84 - +
  • [23] Fully Integrated 2D CMUT Ring Arrays for Endoscopic Ultrasound
    Moini, Azadeh
    Nikoozadeh, Amin
    Choe, Jung Woo
    Chang, Chienliu
    Stephens, Douglas N.
    Sahn, David J.
    Khuri-Yakub, Pierre T.
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [24] Investigating Large 2D Arrays for Photoacoustic and Acoustic Imaging using CMUT Technology
    Vaithilingam, Srikant
    Ma, Te-Jen
    Furukawa, Yukio
    Oralkan, Oemer
    Kamaya, Aya
    Torashima, Kazutoshi
    Kupnik, Mario
    Wygant, Ira O.
    Zhuang, Xuefeng
    Jeffrey, R. Brooke, Jr.
    Khuri-Yakub, Butrus T.
    [J]. 2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1238 - +
  • [25] Medical imaging with capacitive micromachined ultrasound transducer (cMUT) arrays
    Mills, DM
    [J]. 2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 384 - 390
  • [26] 3-D Synthetic Imaging Using 128-Channel 2-D Sparse CMUT Array
    Choi, Won Young
    Kwak, Yun Sang
    Park, Kwan Kyu
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [27] Capacitive Substrate Coupling of Row-Column-Addressed 2-D CMUT Arrays
    Engholm, Mathias
    Bouzari, Hamed
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [28] Probe development of CMUT and PZT row-column-addressed 2-D arrays
    Engholm, Mathias
    Bouzari, Hamed
    Christiansen, Thomas Lehrmann
    Beers, Christopher
    Bagge, Jan Peter
    Moesner, Lars Nordahl
    Diederichsen, Soren Elmin
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2018, 273 : 121 - 133
  • [29] An Integrated Circuit With Transmit Beamforming Flip-Chip Bonded to a 2-D CMUT Array for 3-D Ultrasound Imaging
    Wygant, Ira O.
    Jamal, Nafis S.
    Lee, Hyunjoo J.
    Nikoozadeh, Amin
    Oralkan, Oemer
    Karaman, Mustafa
    Khuri-Yakub, Butrus T.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) : 2145 - 2156
  • [30] A simple 2-D ultrasound array and front-end electronics for 3-D volumetric imaging
    Zhi, Y
    Guo, PY
    Zhu, Q
    [J]. PROCEEDINGS OF THE IEEE 25TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 1999, : 85 - 86