Hybrid Volume Beamforming for 3-D Ultrasound Imaging using 2-D CMUT Arrays

被引:7
|
作者
Kim, Bae-Hyung [1 ]
Song, Tai-Kyong
Yoo, Yangmo
Chang, Jin Ho
Lee, Seunghun [1 ]
Kim, Youngil [1 ]
Cho, Kyungil [1 ]
Song, Jongkeun [1 ]
机构
[1] Samsung Elect Co, Samsung Adv Inst Technol, Future IT Res Ctr, Yongin, South Korea
关键词
Volume beamforming and scanning; Real-time 3-D ultrasound imaging; 2-D CMUT arrays;
D O I
10.1109/ULTSYM.2012.0561
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In real-time 3-D (4-D) ultrasound imaging using 2-D array transducers, manipulating massive ultrasound data acquired from a large number of system channels is a challenge as is interconnecting thousands of elements of 2-D array with the imaging system's front-end electronics. Minimizing the number of transmitting and receiving channels and the firing events without degrading the image quality is one of solutions to reduce the overall system complexity and improve the frame rate. This paper introduces a hybrid volume beam-forming and scanning method for a medical ultrasound imaging system. We also present an efficient volume image-forming architecture using 2-D arrays for miniaturized volumetric ultrasound imaging scanners. To evaluate our works, computer simulations are performed. From the simulation results, we have shown that the presented method provides the comparable image quality to the fully-sampled array (FSA) beam-formation, and is feasible for real-time volumetric ultrasound scanners with miniature devices.
引用
收藏
页码:2246 / 2249
页数:4
相关论文
共 50 条
  • [1] Beamforming and Imageforming for 3D Ultrasound Imaging System using 2-D CMUT-on-ASIC Arrays
    Park, Suhyun
    Kim, Bae-Hyung
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Jeon, Taeho
    Song, Jongkeun
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1440 - 1443
  • [2] Volumetric ultrasound Imaging using 2-D CMUT arrays
    Oralkan, Ö
    Ergun, AS
    Cheng, CH
    Johnson, JA
    Karaman, M
    Lee, TH
    Khuri-Yakub, BT
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (11) : 1581 - 1594
  • [3] An Integrated Circuit With Transmit Beamforming Flip-Chip Bonded to a 2-D CMUT Array for 3-D Ultrasound Imaging
    Wygant, Ira O.
    Jamal, Nafis S.
    Lee, Hyunjoo J.
    Nikoozadeh, Amin
    Oralkan, Oemer
    Karaman, Mustafa
    Khuri-Yakub, Butrus T.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) : 2145 - 2156
  • [4] Integrated Circuits for Volumetric Ultrasound Imaging With 2-D CMUT Arrays
    Bhuyan, Anshuman
    Choe, Jung Woo
    Lee, Byung Chul
    Wygant, Ira O.
    Nikoozadeh, Amin
    Oralkan, Omer
    Khuri-Yakub, Butrus T.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (06) : 796 - 804
  • [5] Top Orthogonal to Bottom Electrode (TOBE) 2-D CMUT Arrays for 3-D Photoacoustic Imaging
    Chee, Ryan K. W.
    Sampaleanu, Alexander
    Rishi, Deepak
    Zemp, Roger J.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (08) : 1393 - 1395
  • [6] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Emmanuel Roux
    François Varray
    Lorena Petrusca
    Christian Cachard
    Piero Tortoli
    Hervé Liebgott
    [J]. Scientific Reports, 8
  • [7] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Roux, Emmanuel
    Varray, Francois
    Petrusca, Lorena
    Cachard, Christian
    Tortoli, Piero
    Liebgott, Herve
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [8] 3-D Synthetic Imaging Using 128-Channel 2-D Sparse CMUT Array
    Choi, Won Young
    Kwak, Yun Sang
    Park, Kwan Kyu
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [9] 3-D ultrasound imaging using forward viewing CMUT ring arrays for intravascular and intracardiac applications
    Yeh, DT
    Oralkan, Ö
    Wygant, IO
    O'Donnell, M
    Khuri-Yakub, BT
    [J]. 2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 783 - 786
  • [10] 2-D army for 3-D ultrasound imaging using synthetic aperture techniques
    Daher, NM
    Yen, JT
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) : 912 - 924