Integrated Circuits for Volumetric Ultrasound Imaging With 2-D CMUT Arrays

被引:82
|
作者
Bhuyan, Anshuman [1 ]
Choe, Jung Woo [1 ]
Lee, Byung Chul [1 ]
Wygant, Ira O. [2 ]
Nikoozadeh, Amin [1 ]
Oralkan, Omer [3 ]
Khuri-Yakub, Butrus T. [1 ]
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
[2] Texas Instruments Inc, Sunnyvale, CA 94089 USA
[3] N Carolina State Univ, Dept Elect Engn, Raleigh, NC 27606 USA
关键词
2D array; capacitive micromachined ultrasonic transducer (CMUT); flip-chip bonding; integrated circuits; phased array imaging; ultrasound; volumetric imaging; TRANSDUCERS; VOLTAGE; FETUS;
D O I
10.1109/TBCAS.2014.2298197
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Real-time volumetric ultrasound imaging systems require transmit and receive circuitry to generate ultrasound beams and process received echo signals. The complexity of building such a system is high due to requirement of the front-end electronics needing to be very close to the transducer. A large number of elements also need to be interfaced to the back-end system and image processing of a large dataset could affect the imaging volume rate. In this work, we present a 3-D imaging system using capacitive micromachined ultrasonic transducer (CMUT) technology that addresses many of the challenges in building such a system. We demonstrate two approaches in integrating the transducer and the front-end electronics. The transducer is a 5-MHz CMUT array with an 8 mm x 8 mm aperture size. The aperture consists of 1024 elements (32 x 32) with an element pitch of 250 mu m. An integrated circuit (IC) consists of a transmit beamformer and receive circuitry to improve the noise performance of the overall system. The assembly was interfaced with an FPGA and a back-end system (comprising of a data acquisition system and PC). The FPGA provided the digital I/O signals for the IC and the back-end system was used to process the received RF echo data (from the IC) and reconstruct the volume image using a phased array imaging approach. Imaging experiments were performed using wire and spring targets, a ventricle model and a human prostrate. Real-time volumetric images were captured at 5 volumes per second and are presented in this paper.
引用
下载
收藏
页码:796 / 804
页数:9
相关论文
共 50 条
  • [1] Volumetric ultrasound Imaging using 2-D CMUT arrays
    Oralkan, Ö
    Ergun, AS
    Cheng, CH
    Johnson, JA
    Karaman, M
    Lee, TH
    Khuri-Yakub, BT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (11) : 1581 - 1594
  • [2] VOLUMETRIC ELASTICITY IMAGING WITH A 2-D CMUT ARRAY
    Fisher, Ted G.
    Hall, Timothy J.
    Panda, Satchi
    Richards, Michael S.
    Barbone, Paul E.
    Jiang, Jingfeng
    Resnick, Jeff
    Barnes, Steve
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (06): : 978 - 990
  • [3] Dual-Mode Integrated Circuit for Imaging and HIFU With 2-D CMUT Arrays
    Jang, Ji Hoon
    Rasmussen, Morten Fischer
    Bhuyan, Anshuman
    Yoon, Hyo-Seon
    Moini, Azadeh
    Chang, Chienliu
    Watkins, Ronald D.
    Choe, Jung Woo
    Nikoozadeh, Amin
    Stephens, Douglas
    Oralkan, Oemer
    Pauly, Kim Butts
    Khuri-Yakub, Butrus
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [4] Hybrid Volume Beamforming for 3-D Ultrasound Imaging using 2-D CMUT Arrays
    Kim, Bae-Hyung
    Song, Tai-Kyong
    Yoo, Yangmo
    Chang, Jin Ho
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Song, Jongkeun
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 2246 - 2249
  • [5] Miniaturized Ultrasound Imaging Probes Enabled by CMUT Arrays with Integrated Frontend Electronic Circuits
    Khuri-Yakub, B. T.
    Oralkan, Oemer
    Nikoozadeh, Amin
    Wygant, Ira O.
    Zhuang, Steve
    Gencel, Mustafa
    Choe, Jung Woo
    Stephens, Douglas N.
    de la Rama, Alan
    Chen, Peter
    Lin, Feng
    Dentinger, Aaron
    Wildes, Douglas
    Thomenius, Kai
    Shivkumar, Kalyanam
    Mahajan, Aman
    Seo, Chi Hyung
    O'Donnell, Matthew
    Uyen Truong
    Sahn, David J.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5987 - 5990
  • [6] Volumetric ultrasound image-forming using fully controllable 2-D CMUT-on-ASIC arrays
    Kim, Bae-Hyung
    Song, Jongkeun
    Lee, Seunghun
    Cho, Kyungil
    Kim, Youngil
    Jeon, Taeho
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [7] Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
    Wygant, Ira O.
    Zhuang, Xuefeng
    Yeh, David T.
    Oralkan, Omer
    Ergun, A. Sanli
    Karaman, Mustafa
    Khuri-Yakub, Butrus T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (02) : 327 - 342
  • [8] Beamforming and Imageforming for 3D Ultrasound Imaging System using 2-D CMUT-on-ASIC Arrays
    Park, Suhyun
    Kim, Bae-Hyung
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Jeon, Taeho
    Song, Jongkeun
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1440 - 1443
  • [9] Row-Column Addressed 2-D CMUT Arrays with Integrated Apodization
    Christiansen, Thomas Lehrmann
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 600 - 603
  • [10] Phase-rotation based receive-beamformer for miniaturized volumetric ultrasound imaging scanners using 2-D CMUT-on-ASIC arrays
    Kim, Bae-Hyung
    Lee, Seunghun
    Song, Jongkeun
    Kim, Youngil
    Jeon, Taeho
    Cho, Kyungil
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675