Integrated Circuits for Volumetric Ultrasound Imaging With 2-D CMUT Arrays

被引:82
|
作者
Bhuyan, Anshuman [1 ]
Choe, Jung Woo [1 ]
Lee, Byung Chul [1 ]
Wygant, Ira O. [2 ]
Nikoozadeh, Amin [1 ]
Oralkan, Omer [3 ]
Khuri-Yakub, Butrus T. [1 ]
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
[2] Texas Instruments Inc, Sunnyvale, CA 94089 USA
[3] N Carolina State Univ, Dept Elect Engn, Raleigh, NC 27606 USA
关键词
2D array; capacitive micromachined ultrasonic transducer (CMUT); flip-chip bonding; integrated circuits; phased array imaging; ultrasound; volumetric imaging; TRANSDUCERS; VOLTAGE; FETUS;
D O I
10.1109/TBCAS.2014.2298197
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Real-time volumetric ultrasound imaging systems require transmit and receive circuitry to generate ultrasound beams and process received echo signals. The complexity of building such a system is high due to requirement of the front-end electronics needing to be very close to the transducer. A large number of elements also need to be interfaced to the back-end system and image processing of a large dataset could affect the imaging volume rate. In this work, we present a 3-D imaging system using capacitive micromachined ultrasonic transducer (CMUT) technology that addresses many of the challenges in building such a system. We demonstrate two approaches in integrating the transducer and the front-end electronics. The transducer is a 5-MHz CMUT array with an 8 mm x 8 mm aperture size. The aperture consists of 1024 elements (32 x 32) with an element pitch of 250 mu m. An integrated circuit (IC) consists of a transmit beamformer and receive circuitry to improve the noise performance of the overall system. The assembly was interfaced with an FPGA and a back-end system (comprising of a data acquisition system and PC). The FPGA provided the digital I/O signals for the IC and the back-end system was used to process the received RF echo data (from the IC) and reconstruct the volume image using a phased array imaging approach. Imaging experiments were performed using wire and spring targets, a ventricle model and a human prostrate. Real-time volumetric images were captured at 5 volumes per second and are presented in this paper.
引用
下载
收藏
页码:796 / 804
页数:9
相关论文
共 50 条
  • [21] 2-D thermal imaging of the optical power distribution in photonic integrated circuits
    Lüerssen, D
    Ram, RJ
    Hudgings, JA
    2004 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2004, : 163 - 164
  • [22] A Volumetric CMUT-Based Ultrasound Imaging System Simulator With Integrated Reception and μ-Beamforming Electronics Models
    Matrone, Giulia
    Savoia, Alessandro S.
    Terenzi, Marco
    Caliano, Giosue
    Quaglia, Fabio
    Magenes, Giovanni
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (05) : 792 - 804
  • [23] HYBRID BEAMFORMATION FOR VOLUMETRIC ULTRASOUND IMAGING SCANNERS USING 2-D ARRAY TRANSDUCERS
    Kim, Bae-Hyung
    Lee, Seungheun
    Kim, Youngil
    Cho, Kyungil
    Kim, Dongwook
    Song, Jongkeun
    2012 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2012), 2012, : 2297 - 2300
  • [24] Annular CMUT arrays for side looking intravascular ultrasound imaging
    Zahorian, Jaime
    Guldiken, Rasim
    Gurun, Gokce
    Qureshi, M. Shakeel
    Balantekin, Mujdat
    Degertekin, F. Levent
    Carlier, Stephane
    Sisman, Alper
    Karaman, Mustafa
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 84 - +
  • [25] Medical imaging with capacitive micromachined ultrasound transducer (cMUT) arrays
    Mills, DM
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 384 - 390
  • [26] Capacitive Substrate Coupling of Row-Column-Addressed 2-D CMUT Arrays
    Engholm, Mathias
    Bouzari, Hamed
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [27] Probe development of CMUT and PZT row-column-addressed 2-D arrays
    Engholm, Mathias
    Bouzari, Hamed
    Christiansen, Thomas Lehrmann
    Beers, Christopher
    Bagge, Jan Peter
    Moesner, Lars Nordahl
    Diederichsen, Soren Elmin
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 273 : 121 - 133
  • [28] Two-dimensional capacitive micromachined ultrasonic transducer (CMUT) arrays for a miniature integrated volumetric ultrasonic imaging system
    Zhuang, X
    Wygant, IO
    Yeh, DT
    Nikoozadeh, A
    Oralkan, O
    Ergun, AS
    Cheng, CH
    Huang, Y
    Yaralioglu, GG
    Khuri-Yakub, BT
    MEDICAL IMAGING 2005: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2005, 5750 : 37 - 46
  • [29] An Integrated Ring CMUT Array for Endoscopic Ultrasound and Photoacoustic Imaging
    Nikoozadeh, Amin
    Chang, Chienliu
    Choe, Jung Woo
    Bhuyan, Anshuman
    Lee, Byung Chul
    Moini, Azadeh
    Khuri-Yakub, Pierre T.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1170 - 1173
  • [30] A simple 2-D ultrasound array and front-end electronics for 3-D volumetric imaging
    Zhi, Y
    Guo, PY
    Zhu, Q
    PROCEEDINGS OF THE IEEE 25TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 1999, : 85 - 86