Validation of mammographic x-ray spectra generated using Particle and Heavy Ion Transport code System

被引:3
|
作者
Chusin, Thunyarat [1 ,2 ]
Matsubara, Kosuke [3 ]
Takemura, Akihiro [3 ]
Okubo, Rena [4 ]
Ogawa, Yoshinori [1 ]
机构
[1] Kanazawa Univ, Dept Quantum Med Technol, Div Hlth Sci, Grad Sch Med Sci, Kanazawa, Ishikawa, Japan
[2] Naresuan Univ, Dept Radiol Technol, Fac Allied Hlth Sci, Phitsanulok, Thailand
[3] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, Kanazawa, Ishikawa, Japan
[4] Daiyukai Hlth Syst, Dept Radiol Technol, Ichinomiya, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 06期
关键词
x-ray spectra; Monte Carlo simulation; PHITS; breast imaging; mammography; MONTE-CARLO-SIMULATION; DIAGNOSTIC-RADIOLOGY; TUNGSTEN-ANODE; MOLYBDENUM; MODELS; PHITS; RHODIUM;
D O I
10.1088/1361-6560/ab735c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A Monte Carlo (MC) code is a robust method to generate a mammographic x-ray spectrum because the geometry of a mammography system can be flexible and directly modeled in MC simulation. However, simulations from MC code need to be validated before it can be reliably used for specific applications. This study aimed to generate and validate the x-ray spectra of relevant anodes used in mammography and breast tomosynthesis using Particle and Heavy Ion Transport code System (PHITS). PHITS version 3.08 was used to generate the x-ray spectra of molybdenum (Mo), rhodium (Rh), and tungsten (W) anodes. The Mo anode spectrum derived using PHITS was compared with those obtained using other MC codes. The generated spectra of all anodes were compared with the literature. Parameters including spectral shape, K characteristic x-ray yield, heel effect, and half-value layer (HVL) were used for a comparative assessment. The differences in these assessment parameters conducted by PHITS and PHITSEGS5 simulations were studied. Regarding the comparative parameters, PHITSEGS5 simulation improved the accuracy of mammographic x-ray generation compared to PHITS simulation; K x-ray and bremsstrahlung yields of the Mo anode spectrum generated by PHITSEGS5 simulation were a better agreement with those generated by other MC code simulations. The PHITSEGS5 spectra overestimated K x-ray and low-energy bremsstrahlung photons in comparison with measured spectra. Subsequently, HVLs calculated from PHITSEGS5 spectra were 1.0% (Mo/Mo) and 7.0% (W/Al) lower than those derived from measured spectra. For Mo and Rh anodes, relative difference of HVLs calculated from PHITSEGS5 spectra and those obtained from literature and measurement were within the TRS 457 acceptance criteria (+/- 0.02 mm Al). The observed difference exceeded the acceptance criteria for W anode. Regarding existed consistency in HVL between simulation and measurement, PHITSEGS5 simulation can be reliably used to generate x-ray spectra of Mo and Rh anodes. However, its accuracy should be improved for generating W anode spectrum.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Heavy-ion-induced mutations in the gpt delta transgenic mouse:: Comparison of mutation spectra induced by heavy-ion, X-ray, and γ-ray radiation
    Masumura, K
    Kuniya, K
    Kurobe, T
    Fukuoka, M
    Yatagai, F
    Nohmi, T
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2002, 40 (03) : 207 - 215
  • [42] UNCHARACTERISTIC X-RAY SPECTRA PRODUCED BY MEV HEAVY IONS
    RICHARD, P
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (11): : 1350 - &
  • [43] Comparison of the Heavy Ion Transport Code, PHITS and Measurements: Secondary Particle Production
    Lee, C. W.
    Lee, Y. O.
    Yang, S. C.
    Min, B. J.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 2043 - 2046
  • [44] ION X-RAY COINCIDENCE MEASUREMENTS IN HEAVY-ION COLLISIONS
    GRAHAM, WG
    BERNSTEIN, EM
    CLARK, MW
    TANIS, JA
    BERKNER, KH
    SCHLACHTER, AS
    STEARNS, JW
    JOHNSON, BM
    JONES, KW
    MERON, M
    MCFARLAND, RH
    MORGAN, TJ
    STOCKLI, MP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 24-5 : 69 - 73
  • [45] Applicability of particle and heavy ion transport code PHITS to the shielding design of spacecrafts
    Sato, Tatsuhiko
    Niita, Koji
    Iwase, Hiroshi
    Nakashima, Hiroshi
    Yamaguchi, Yasuhiro
    Sihver, Lembit
    RADIATION MEASUREMENTS, 2006, 41 (9-10) : 1142 - 1146
  • [46] Swift heavy ion induced modification in Fe/Ti system studied using X-ray waveguide structure
    Rajput, Parasmani
    Gupta, Ajay
    Avasthi, D. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (08): : 1680 - 1684
  • [47] Normalized glandular dose (DgN) coefficients from experimental mammographic x-ray spectra
    Santos, Josilene C.
    Tomal, Alessandra
    de Barros, Nestor
    Costa, Paulo R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (10):
  • [48] Identification of tungsten spectra in X-ray range on EAST Tokamak using Flexible Atomic Code
    Ji, H.
    Zhang, H.
    Lyu, B.
    Yang, Y.
    Huang, S.
    Lin, Z.
    Fu, J.
    Wang, F.
    Yin, X.
    Sunab, B.
    Shene, Y.
    JOURNAL OF INSTRUMENTATION, 2025, 20 (03):
  • [49] Computer Simulation of CNT Field Emitter Based X-ray Spectra Using with FLUKA Code
    Song, H. S.
    Kim, H. W.
    Zhou, T.
    Lee, B. N.
    Lee, Y. S.
    Lee, S. H.
    Choi, H. J.
    Yeon, Y. H.
    Oh, J. H.
    Gad, Kh. M.
    Kadi, Y.
    Chai, J. S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 1999 - 2001
  • [50] Bone densitometry using X-ray spectra
    Krmar, M
    Ganezer, K
    Shukla, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1747 - 1747