Validation of mammographic x-ray spectra generated using Particle and Heavy Ion Transport code System

被引:3
|
作者
Chusin, Thunyarat [1 ,2 ]
Matsubara, Kosuke [3 ]
Takemura, Akihiro [3 ]
Okubo, Rena [4 ]
Ogawa, Yoshinori [1 ]
机构
[1] Kanazawa Univ, Dept Quantum Med Technol, Div Hlth Sci, Grad Sch Med Sci, Kanazawa, Ishikawa, Japan
[2] Naresuan Univ, Dept Radiol Technol, Fac Allied Hlth Sci, Phitsanulok, Thailand
[3] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, Kanazawa, Ishikawa, Japan
[4] Daiyukai Hlth Syst, Dept Radiol Technol, Ichinomiya, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 06期
关键词
x-ray spectra; Monte Carlo simulation; PHITS; breast imaging; mammography; MONTE-CARLO-SIMULATION; DIAGNOSTIC-RADIOLOGY; TUNGSTEN-ANODE; MOLYBDENUM; MODELS; PHITS; RHODIUM;
D O I
10.1088/1361-6560/ab735c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A Monte Carlo (MC) code is a robust method to generate a mammographic x-ray spectrum because the geometry of a mammography system can be flexible and directly modeled in MC simulation. However, simulations from MC code need to be validated before it can be reliably used for specific applications. This study aimed to generate and validate the x-ray spectra of relevant anodes used in mammography and breast tomosynthesis using Particle and Heavy Ion Transport code System (PHITS). PHITS version 3.08 was used to generate the x-ray spectra of molybdenum (Mo), rhodium (Rh), and tungsten (W) anodes. The Mo anode spectrum derived using PHITS was compared with those obtained using other MC codes. The generated spectra of all anodes were compared with the literature. Parameters including spectral shape, K characteristic x-ray yield, heel effect, and half-value layer (HVL) were used for a comparative assessment. The differences in these assessment parameters conducted by PHITS and PHITSEGS5 simulations were studied. Regarding the comparative parameters, PHITSEGS5 simulation improved the accuracy of mammographic x-ray generation compared to PHITS simulation; K x-ray and bremsstrahlung yields of the Mo anode spectrum generated by PHITSEGS5 simulation were a better agreement with those generated by other MC code simulations. The PHITSEGS5 spectra overestimated K x-ray and low-energy bremsstrahlung photons in comparison with measured spectra. Subsequently, HVLs calculated from PHITSEGS5 spectra were 1.0% (Mo/Mo) and 7.0% (W/Al) lower than those derived from measured spectra. For Mo and Rh anodes, relative difference of HVLs calculated from PHITSEGS5 spectra and those obtained from literature and measurement were within the TRS 457 acceptance criteria (+/- 0.02 mm Al). The observed difference exceeded the acceptance criteria for W anode. Regarding existed consistency in HVL between simulation and measurement, PHITSEGS5 simulation can be reliably used to generate x-ray spectra of Mo and Rh anodes. However, its accuracy should be improved for generating W anode spectrum.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Simulation of X-Ray Spectra Generated by Electron Impact on Solids
    Fac. de Matemat., Astronomia y Fis., Univ. Nacional de Córdoba, Medina Allende y Haya de la Torre, 5000 Cordoba, Argentina
    不详
    不详
    不详
    X-Ray Spectrom., 2 (121-127):
  • [32] Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging
    Bliznakova, K.
    Speller, R.
    Horrocks, J.
    Liaparinos, P.
    Kolitsi, Z.
    Pallikarakis, N.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2010, 40 (02) : 208 - 214
  • [33] PARTICLE GAMMA RAY COINCIDENCE SPECTRA IN HEAVY-ION REACTIONS
    ZOLNOWSKI, DR
    KAHLER, AC
    YAMADA, H
    CALA, SE
    SUGIHARA, TT
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 165 - 165
  • [34] SELECTION OF HEAVY-ION REACTION CHANNELS VIA PARTICLE K X-RAY COINCIDENCES
    WILSCHUT, HW
    BHOWMIK, RK
    GOLDHOORN, PB
    JANSEN, JFW
    SIEMSSEN, RH
    SIWEKWILCZYNSKA, K
    SUJKOWSKI, Z
    WILCZYNSKI, J
    PHYSICS LETTERS B, 1983, 123 (3-4) : 173 - 176
  • [35] X-RAY EMISSION IN HEAVY ION COLLISIONS.
    Macdonald, James R.
    Japanese journal of applied physics, 1978, 17 Suppl 17-2 : 86 - 92
  • [36] Characteristic X-ray production in heavy ion collisions
    Kiisk, M
    Persson, P
    Hellborg, R
    Smit, Z
    Erlandsson, B
    Faarinen, M
    Skog, G
    Stenstrom, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 172 : 182 - 187
  • [37] CHANGES OF X-RAY PHOTOELECTRON SPECTRA BY ION SPUTTERING
    Hashimoto, Satoshi
    Hirokawa, Kichinosuke
    Fukuda, Yasuo
    Suzuki, Keni-chi
    Suzuki, Toshiko
    Usuki, Noriaki
    Gennai, Norio
    Yoshida, Sizuo
    Koda, Mitsuru
    Sezaki, Hiroshi
    Horie, Hiroshi
    Tanaka, Akihiro
    Ohtsubo, Takashi
    ANALYTICAL SCIENCES, 1991, 7 : 341 - 344
  • [38] Ion emission spectra in the Jovian X-ray aurora
    Kharchenko, V.
    Dalgarno, A.
    Schultz, D. R.
    Stancil, P. C.
    GEOPHYSICAL RESEARCH LETTERS, 2006, 33 (11)
  • [39] Unlocking the nature of ultraluminous X-ray sources using their X-ray spectra
    Gladstone, J. C.
    Roberts, T. P.
    Done, C.
    ASTRONOMISCHE NACHRICHTEN, 2011, 332 (04) : 345 - 348
  • [40] Particle-induced x-ray analysis using focused ion beams
    Giannuzzi, LA
    SCANNING, 2005, 27 (04) : 165 - 169