Effectiveness of four electronic apex locators to determine distance from the apical foramen

被引:42
|
作者
Stoll, R. [1 ]
Urban-Klein, B. [1 ]
Roggendorf, M. J. [1 ]
Jablonski-Momeni, A. [2 ]
Strauch, K. [3 ]
Frankenberger, R. [1 ]
机构
[1] Univ Marburg, Dept Operat Dent & Endodont, Sch Dent, D-35033 Marburg, Germany
[2] Univ Marburg, Dept Pediat Dent, Sch Dent, D-35033 Marburg, Germany
[3] Univ Marburg, Inst Med Biometry & Epidemiol, D-35033 Marburg, Germany
关键词
apical region; electronic apex locator; meter reading display; root canal length determination; IN-VITRO EVALUATION; WORKING LENGTH DETERMINATION; ENLARGED ROOT CANALS; VIVO ACCURACY; ZX; CONSTRICTION; SIZE;
D O I
10.1111/j.1365-2591.2010.01765.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>Aim To evaluate the accuracy of four electronic apex locators (EAL) in the apical region (0-3 mm short of the foramen) and to compare the precision of the readings on the display with the real position of the file in the root canal. Methodology Twenty single-rooted extracted teeth with round root canals were used. The canal orifices were preflared, and the length to the major foramen was determined visually under a microscope. Canals were enlarged, so that a size 15 file fitted well inside the canal. Teeth were mounted in acrylic test tubes filled with physiologic saline solution. Electronic length was determined in the region between the major foramen and 3 mm short of it in 0.5 mm steps with the Dentaport ZX, Root ZX mini, Elements Diagnostic Unit and Apex Locator and Raypex 5 using files of size 10 and size 15. The data were analysed using linear regression between true length and EAL reading, Bland-Altman plots and nonparametric tests at a significance level of alpha = 0.05. Results The major foramen was detected by all EALs. With a measurement file positioned directly at the major foramen, meter readings were equivalent to a position 0.01-0.38 mm away. For the Dentaport ZX, a better accuracy using the size 15 file for the area 0-1.5 mm short of the apex was found. The differences in measurements between the two files were smaller for the other EALs. In linear regression, a good linearity for Dentaport ZX and Root ZX mini and moderate linearity for Elements Diagnostic Unit and Apex Locator and Raypex 5 were found. The slope of the measurement curve was too low (0.37-0.57) for the Raypex 5 and almost optimal for the Dentaport ZX (1.01-1.05). The Root ZX mini and the Elements Obturation Unit produced lower slope values and especially the Elements Obturation Unit revealed much higher SDs at the different measurement levels. Conclusion Amongst the four EALs, the Dentaport ZX and Root ZX mini had the best agreement between true lengths and meter readings. For the Raypex 5, an interpretation of the colour-coded zones as distance to the foramen cannot be recommended and might lead to erroneous interpretations.
引用
收藏
页码:808 / 817
页数:10
相关论文
共 36 条
  • [21] Comparison of the Accuracies of CBCT, Radiography, and Four Electronic Apex Locators in Working Length Determination
    Ozata, Merve Yeniceri
    Falakaloglu, Seda
    Kaya, Sadullah
    MAKARA JOURNAL OF HEALTH RESEARCH, 2022, 26 (01): : 61 - 66
  • [22] Comparison of various current electronic apex locators to determine the working length using the clearing technique
    Altunbas, D.
    Kustarci, A.
    Arslan, D.
    Er, K.
    Kocak, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2015, 18 (03) : 359 - 363
  • [23] Ex vivo comparison of three electronic apex locators to determine working length in endodontic treatment
    Miguita, Kenner Bruno
    de Araujo, Roberta Aranha
    De Martin, Alexandre Sigrist
    da Silveira Bueno, Carlos Eduardo
    Cunha, Rodrigo Sanches
    ENDO-ENDODONTIC PRACTICE TODAY, 2011, 5 (04): : 281 - 284
  • [24] Not All Electronic Foramen Locators Are Accurate in Teeth with Enlarged Apical Foramina: An In Vitro Comparison of 5 Brands
    Akisue, Eduardo
    Gratieri, Simone Domingues
    Barletta, Fernando Branco
    Caldeira, Celso Luiz
    Grazziotin-Soares, Renata
    Gavini, Giulio
    JOURNAL OF ENDODONTICS, 2014, 40 (01) : 109 - 112
  • [25] Comparing the accuracy of four electronic apex locators for determining the minor diameter: An ex vivo study
    Cimilli, Hale
    Aydemir, Seda
    Kartal, Nevin
    Chandler, Nicholas
    JOURNAL OF DENTAL SCIENCES, 2013, 8 (01) : 27 - 30
  • [26] The use of micro-computed tomography to determine the accuracy of electronic working length with two apex locators
    Suguro, Hisashi
    Nishihara, Anna
    Tamura, Takahito
    Nakamura, Takeshi
    Toyama, Yurika
    Takeichi, Osamu
    JOURNAL OF ORAL SCIENCE, 2021, 63 (02) : 167 - 169
  • [27] The difference distance between the apical foramen and the anatomical apex in primary teeth-An in vitro study
    Alafandy, Ansam Shafik
    Makieh, Ramah Eimad
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2023, 9 (05): : 913 - 921
  • [28] An Invitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants
    Ashwini, Prasad B.
    Harshit, Srivastava
    Aastha, Srivastava Arora
    Deepak, Raisingani
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2016, 26 (05) : 457 - 462
  • [29] The Use of Micro-Computed Tomography to Determine the Accuracy of 2 Electronic Apex Locators and Anatomic Variations Affecting Their Precision
    Piasecki, Lucila
    Carneiro, Everdan
    da Silva Neto, Ulisses Xavier
    Ditzel Westphalen, Vania Portela
    Brandao, Christian Giampietro
    Gambarini, Gianluca
    Azim, Adham A.
    JOURNAL OF ENDODONTICS, 2016, 42 (08) : 1263 - 1267
  • [30] Comparative Accuracy and Reliability of Three Electronic Apex Locators in Determining the Apical Constriction of Molar Canals: A Micro-CT Evaluation
    Barakat, Reem M.
    Almohareb, Rahaf A.
    Alharbi, Arwa O.
    Alhazmi, Asma
    Alomar, Reem
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)