Ex vivo comparison of three electronic apex locators to determine working length in endodontic treatment

被引:0
|
作者
Miguita, Kenner Bruno [1 ]
de Araujo, Roberta Aranha [2 ]
De Martin, Alexandre Sigrist [2 ]
da Silveira Bueno, Carlos Eduardo [3 ]
Cunha, Rodrigo Sanches [4 ]
机构
[1] Sao Leopoldo Mandie, Dent Res Ctr, Campinas, SP, Brazil
[2] Sao Leopoldo Mandie, Dent Res Ctr, Campinas, SP, Brazil
[3] Sao Leopoldo Mandie, Dent Res Ctr, Grad Program Endodont, Campinas, SP, Brazil
[4] Univ Manitoba, Div Endodont, Winnipeg, MB, Canada
来源
ENDO-ENDODONTIC PRACTICE TODAY | 2011年 / 5卷 / 04期
关键词
apex locator; endodontics; working length;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This ex vivo study evaluated the accuracy of three electronic apex locators (Root ZX (R) II, Propex II (R) and Elements Diagnostic (R)) in determining working length by comparing their findings with direct measurements. Materials and methods: Forty single-rooted human teeth underwent coronal access and cervical preparation. To determine actual working length, a size 10 K-file was inserted to the point where its tip was visible at the apical foramen under 8x magnification; a rubber stop was placed at the level of the incisal edge, and working length was measured with a millimetre endodontic ruler. The teeth were then mounted on a piece of floral foam soaked in 0.9% sodium chloride, and electronic measurements were made using the foramen identification criterion for apex location of the Root ZX II, Propex II and Elements Diagnostic units. Results: Analysis of variance (ANOVA; P = 0.9987) showed no statistically significant differences between the three electronic apex locators at either tolerance level. Root ZX II had a 93% accuracy rate, Propex II 90% and Elements Diagnostic 91%. No statistically significant differences were found between the locators being tested (P > 0.05), with a safety margin of +/- 0.5 mm. Conclusion: The three locators had acceptable accuracy rates for clinical use.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [1] An ex vivo comparison of working length determination by 3 electronic apex locators
    Pascon, Elizeu Alvaro
    Marrelli, Massimo
    Congi, Orsola
    Ciancio, Rosetta
    Miceli, Federica
    Versiani, Marco Aurelio
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03): : E147 - E151
  • [2] An ex vivo comparison of three electronic apex locators
    Baginska, Joanna
    Linczuk, Ewa
    Botulinski, Bartlomiej
    Kierklo, Anna
    HEALTHMED, 2012, 6 (10): : 3275 - 3280
  • [3] In vivo comparison of working length determination with two electronic apex locators
    Wrbas, K. T.
    Ziegler, A. A.
    Altenburger, M. J.
    Schirrmeister, J. F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (02) : 133 - 138
  • [4] Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters
    Ebrahim, A. K.
    Wadachi, R.
    Suda, H.
    AUSTRALIAN DENTAL JOURNAL, 2006, 51 (03) : 258 - 262
  • [5] Comparison of various current electronic apex locators to determine the working length using the clearing technique
    Altunbas, D.
    Kustarci, A.
    Arslan, D.
    Er, K.
    Kocak, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2015, 18 (03) : 359 - 363
  • [6] An ex vivo comparison of root canal length determination by three electronic apex locators at positions short of the apical foramen
    de Vasconcelos, Bruno Carvalho
    do Vale, Taina Macedo
    Teixeira de Menezes, Antonio Sergio
    Pinheiro-Junior, Elilton Cavalcante
    Vivacqua-Gomes, Nilton
    Bernardes, Ricardo Affonso
    Hungaro Duarte, Marco Antonio
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (02): : E57 - E61
  • [7] An in vivo comparison of working length determination of two frequency-based electronic apex locators
    Pascon, E. A.
    Marrelli, M.
    Congi, O.
    Ciancio, R.
    Miceli, F.
    Versiani, M. A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (11) : 1026 - 1031
  • [8] A comparison between two electronic apex locators:: an ex vivo investigation
    Venturi, M.
    Breschi, L.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (05) : 362 - 373
  • [9] Comparison of working length determination with radiographs and four electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (06) : 510 - 518
  • [10] Comparison of working length determination with radiographs and two electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    Mondaca, J. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (01) : 16 - 20