Ex vivo comparison of three electronic apex locators to determine working length in endodontic treatment

被引:0
|
作者
Miguita, Kenner Bruno [1 ]
de Araujo, Roberta Aranha [2 ]
De Martin, Alexandre Sigrist [2 ]
da Silveira Bueno, Carlos Eduardo [3 ]
Cunha, Rodrigo Sanches [4 ]
机构
[1] Sao Leopoldo Mandie, Dent Res Ctr, Campinas, SP, Brazil
[2] Sao Leopoldo Mandie, Dent Res Ctr, Campinas, SP, Brazil
[3] Sao Leopoldo Mandie, Dent Res Ctr, Grad Program Endodont, Campinas, SP, Brazil
[4] Univ Manitoba, Div Endodont, Winnipeg, MB, Canada
来源
ENDO-ENDODONTIC PRACTICE TODAY | 2011年 / 5卷 / 04期
关键词
apex locator; endodontics; working length;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This ex vivo study evaluated the accuracy of three electronic apex locators (Root ZX (R) II, Propex II (R) and Elements Diagnostic (R)) in determining working length by comparing their findings with direct measurements. Materials and methods: Forty single-rooted human teeth underwent coronal access and cervical preparation. To determine actual working length, a size 10 K-file was inserted to the point where its tip was visible at the apical foramen under 8x magnification; a rubber stop was placed at the level of the incisal edge, and working length was measured with a millimetre endodontic ruler. The teeth were then mounted on a piece of floral foam soaked in 0.9% sodium chloride, and electronic measurements were made using the foramen identification criterion for apex location of the Root ZX II, Propex II and Elements Diagnostic units. Results: Analysis of variance (ANOVA; P = 0.9987) showed no statistically significant differences between the three electronic apex locators at either tolerance level. Root ZX II had a 93% accuracy rate, Propex II 90% and Elements Diagnostic 91%. No statistically significant differences were found between the locators being tested (P > 0.05), with a safety margin of +/- 0.5 mm. Conclusion: The three locators had acceptable accuracy rates for clinical use.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [41] Comparing the accuracy of four electronic apex locators for determining the minor diameter: An ex vivo study
    Cimilli, Hale
    Aydemir, Seda
    Kartal, Nevin
    Chandler, Nicholas
    JOURNAL OF DENTAL SCIENCES, 2013, 8 (01) : 27 - 30
  • [42] Integrated electronic apex locators for determining working length: a systematic review of in-vitro studies
    La Rosa, Giusy Rita Maria
    Angjelova, Angela
    Jovanova, Elena
    Apostolska, Sonja
    Santos, Joao Miguel
    Pedulla, Eugenio
    ODONTOLOGY, 2024,
  • [43] An ex vivo comparison of working length determination by three electronic root canal length measurement devices integrated into endodontic rotary motors (vol 20, pg 2303, 2016)
    Maree-Ali, Manal
    Wigler, Ronald
    Lin, Shaul
    Kaufman, Arieh Y.
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (08) : 2309 - 2309
  • [44] Comparative Evaluation of Accuracy of 2 Electronic Apex Locators with Conventional Radiography: An Ex vivo Study
    Khandewal, Deepika
    Ballal, Nidambur Vasudev
    Saraswathi, Muliya Vidya
    JOURNAL OF ENDODONTICS, 2015, 41 (02) : 201 - 204
  • [45] Accuracy of working length determination using 3 electronic apex locators and direct digital radiography
    Real, Denis Goncalves
    Davidowicz, Harry
    Moura-Netto, Cacio
    Londero Zenkner, Clacir de Lourdes
    Londero Pagliarin, Claudia Medianeira
    Barletta, Fernando Branco
    Maranhao de Moura, Abilio Albuquerque
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 111 (03): : E44 - E49
  • [47] Effectiveness of a new electronic apex locator in two modalities in detecting the working length: an ex vivo study
    Castagnola, Raffaella
    Diana, Rosalba
    Colangeli, Mauro
    Panzetta, Claudia
    Marigo, Luca
    Grande, Nicola Maria
    Plotino, Gianluca
    GIORNALE ITALIANO DI ENDODONZIA, 2021, 35 (01): : 24 - 30
  • [48] Ex vivo evaluation of the accuracy and coefficient of repeatability of three electronic apex locators using a simple mounting model: a preliminary report
    D'Assuncao, F. L. C.
    Albuquerque, D. S.
    Salazar-Silva, J. R.
    Dos Santos, V. C.
    Sousa, J. C. N.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (04) : 269 - 274
  • [49] In vitro evaluation of the accuracy of three electronic apex locators
    Lucena-Martín, C
    Robles-Gijón, V
    Ferrer-Luque, M
    de Mondelo, JMNR
    JOURNAL OF ENDODONTICS, 2004, 30 (04) : 231 - 233
  • [50] Comparison of two electronic apex locators on human cadavers
    Luca Marigo
    Gian Luca Gervasi
    Francesco Somma
    Giuseppe Squeo
    Raffaella Castagnola
    Clinical Oral Investigations, 2016, 20 : 1547 - 1550