Ex vivo comparison of three electronic apex locators to determine working length in endodontic treatment

被引:0
|
作者
Miguita, Kenner Bruno [1 ]
de Araujo, Roberta Aranha [2 ]
De Martin, Alexandre Sigrist [2 ]
da Silveira Bueno, Carlos Eduardo [3 ]
Cunha, Rodrigo Sanches [4 ]
机构
[1] Sao Leopoldo Mandie, Dent Res Ctr, Campinas, SP, Brazil
[2] Sao Leopoldo Mandie, Dent Res Ctr, Campinas, SP, Brazil
[3] Sao Leopoldo Mandie, Dent Res Ctr, Grad Program Endodont, Campinas, SP, Brazil
[4] Univ Manitoba, Div Endodont, Winnipeg, MB, Canada
来源
ENDO-ENDODONTIC PRACTICE TODAY | 2011年 / 5卷 / 04期
关键词
apex locator; endodontics; working length;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This ex vivo study evaluated the accuracy of three electronic apex locators (Root ZX (R) II, Propex II (R) and Elements Diagnostic (R)) in determining working length by comparing their findings with direct measurements. Materials and methods: Forty single-rooted human teeth underwent coronal access and cervical preparation. To determine actual working length, a size 10 K-file was inserted to the point where its tip was visible at the apical foramen under 8x magnification; a rubber stop was placed at the level of the incisal edge, and working length was measured with a millimetre endodontic ruler. The teeth were then mounted on a piece of floral foam soaked in 0.9% sodium chloride, and electronic measurements were made using the foramen identification criterion for apex location of the Root ZX II, Propex II and Elements Diagnostic units. Results: Analysis of variance (ANOVA; P = 0.9987) showed no statistically significant differences between the three electronic apex locators at either tolerance level. Root ZX II had a 93% accuracy rate, Propex II 90% and Elements Diagnostic 91%. No statistically significant differences were found between the locators being tested (P > 0.05), with a safety margin of +/- 0.5 mm. Conclusion: The three locators had acceptable accuracy rates for clinical use.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [31] An in vivo comparison of accuracy of two electronic apex locators in determining working length using stainless steel and nickel titanium files
    Chaudhary, Sanjeeb
    Gharti, Archana
    Adhikari, Bhawana
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2018, 10 : 75 - 82
  • [32] An in vivo comparison of gradient and absolute impedance electronic apex locators
    Lauper, R
    Lutz, F
    Barbakow, F
    JOURNAL OF ENDODONTICS, 1996, 22 (05) : 260 - 263
  • [33] A comparison between two electronic apex locators:: an in vivo investigation
    Venturi, M
    Breschi, L
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (01) : 36 - 45
  • [34] Electronic Apex Locators May Be Better at Determining Endodontic Working Length Than Radiographs and Could Reduce Patient Radiation Exposure
    Chandler, Nicholas
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2015, 15 (01) : 28 - 29
  • [35] Ex vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth
    Leonardo, M. R.
    Silva, L. A. B.
    Nelson-Filho, P.
    Silva, R. A. B.
    Raffaini, M. S. G. G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2008, 41 (04) : 317 - 321
  • [36] Use of electronic apex locators may improve determination of working lengthQuestion: Are electronic apex locators (EALs) accurate?
    Isabel Mello
    Evidence-Based Dentistry, 2014, 15 (4) : 120 - 120
  • [37] An in vivo comparison of two frequency-based electronic apex locators
    Welk, AR
    Baumgartner, JC
    Marshall, JG
    JOURNAL OF ENDODONTICS, 2003, 29 (08) : 497 - 500
  • [38] The accuracy of electronic apex locators for determining working length: An in vitro study with artificial teeth
    Bernardo, Raquel C. F. D.
    Alves, Louise S.
    Bruno, Adilia M., V
    Coutinho, Thais M. C.
    Gusman, Heloisa
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (02) : 217 - 221
  • [39] Exact determination of the working length by electronic apex locators, digital radiology, and visual test: presentation of a new experimental research strategy - an ex-vivo study
    Cianconi, Luigi
    Angotti, Vincenzo
    Felici, Roberto
    Conte, Gabriele
    Mancini, Manuele
    GIORNALE ITALIANO DI ENDODONZIA, 2011, 25 (01): : 24 - 32
  • [40] Clinical reproducibility of three electronic apex locators
    Miletic, V.
    Beljic-Ivanovic, K.
    Ivanovic, V.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (08) : 769 - 776