An in vivo comparison of gradient and absolute impedance electronic apex locators

被引:19
|
作者
Lauper, R [1 ]
Lutz, F [1 ]
Barbakow, F [1 ]
机构
[1] UNIV ZURICH,ORAL & DENT CTR,DEPT PREVENT DENT PERIODONTOL & CARIOL,CH-8028 ZURICH,SWITZERLAND
关键词
D O I
10.1016/S0099-2399(06)80145-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Two electronic apex locators based on the gradient (Apit) and absolute (Odontometer) impedance principles were evaluated, Distances of file tips to apical foramina were determined in vivo with the electronic apex locators and subsequently verified after extraction, Mean differences between file tips and apical foramina were +0.14 +/- 0.27 mm and -0.36 +/- 0.71 mm for the Apit and Odontometer, respectively, These differences were statistically significant (p < 0.001), The Apit's and Odontometer's results ranged from +0.85 to -0.65 mm and from +0.35 to -2.45 mm from the apical foramen, respectively, Ninety-three and 73% of the findings for the Apit and the Odontometer, respectively, were within the +/-0.5 mm range, whereas 100% and 86%, respectively, were within the +/-1.0 mm range, Thirty-three and 43% of the results for the Apit and the Odontometer, respectively, were 1.0 mm or less coronal to the apical foramen, The Apit tended to yield the more reliable results because of the narrower range.
引用
收藏
页码:260 / 263
页数:4
相关论文
共 50 条
  • [1] An ex vivo comparison of three electronic apex locators
    Baginska, Joanna
    Linczuk, Ewa
    Botulinski, Bartlomiej
    Kierklo, Anna
    [J]. HEALTHMED, 2012, 6 (10): : 3275 - 3280
  • [2] An in vivo comparison of five different electronic apex locators
    Al-Shaher, Abdulaziz A.
    Madi, Samar
    [J]. ENDO-ENDODONTIC PRACTICE TODAY, 2011, 5 (01): : 17 - 25
  • [3] In vivo comparison of the accuracy of two electronic apex locators
    Silveira, Luiz F. M.
    Petry, Fernanda V.
    Martos, Josue
    Neto, Joao B. C.
    [J]. AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (02) : 70 - 72
  • [4] A comparison between two electronic apex locators:: an in vivo investigation
    Venturi, M
    Breschi, L
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (01) : 36 - 45
  • [5] In vivo comparison of working length determination with two electronic apex locators
    Wrbas, K. T.
    Ziegler, A. A.
    Altenburger, M. J.
    Schirrmeister, J. F.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (02) : 133 - 138
  • [6] An in vivo comparison of two frequency-based electronic apex locators
    Welk, AR
    Baumgartner, JC
    Marshall, JG
    [J]. JOURNAL OF ENDODONTICS, 2003, 29 (08) : 497 - 500
  • [7] Accuracy of electronic apex locators in comparison to actual length - an in vivo study
    Haffner, C
    Folwaczny, M
    Galler, K
    Hickel, R
    [J]. JOURNAL OF DENTISTRY, 2005, 33 (08) : 619 - 625
  • [8] A comparison between two electronic apex locators:: an ex vivo investigation
    Venturi, M.
    Breschi, L.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (05) : 362 - 373
  • [9] In Vitro Comparison of Three Electronic Apex Locators
    Guise, George M.
    Goodell, Gary G.
    Imamura, Glen M.
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (02) : 279 - 281
  • [10] Ex vivo comparison of two electronic apex locators with different scales and frequencies
    Hör, D
    Krusy, S
    Attin, T
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (12) : 855 - 859