An in vivo comparison of two frequency-based electronic apex locators

被引:69
|
作者
Welk, AR [1 ]
Baumgartner, JC [1 ]
Marshall, JG [1 ]
机构
[1] Oregon Hlth Sci Univ, Sch Dent, Dept Endodontol, Portland, OR 97201 USA
关键词
D O I
10.1097/00004770-200308000-00002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare the accuracy of a two-frequency (Root ZX) and a five-frequency (Endo Analyzer Model 8005) electronic apex locator under clinical conditions. Thirty-two teeth planned for extraction were used. The coronal portion of each canal was flared using Gates Glidden drills and Orifice Shapers. The canals were irrigated with 2.6% sodium hypochlorite. A K-type file was used to determine a separate working length in each canal using the electronic apex locators. The teeth were extracted and the apical 4 mm of each root canal was exposed along the long axis of the tooth. Photographic slides of each canal were projected and the file position in relation to the minor diameter was determined by two investigators. The mean distance between the electronic apex locator working length and minor diameter was 1.03 mm for the Endo Analyzer and 0.19 mm for the Root ZX. A paired sample t test showed that the Endo Analyzer had significantly longer readings beyond the minor diameter than the Root ZX (p < 0.0001). The ability to locate the minor diameter (+/- 0.5 mm) was 90.7% for the Root ZX and 34.4% for the Endo Analyzer Model 8005.
引用
收藏
页码:497 / 500
页数:4
相关论文
共 50 条
  • [1] An in vivo comparison of working length determination of two frequency-based electronic apex locators
    Pascon, E. A.
    Marrelli, M.
    Congi, O.
    Ciancio, R.
    Miceli, F.
    Versiani, M. A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (11) : 1026 - 1031
  • [2] Comparison of the Reliability of "0.5" and "APEX" Mark Measurements in Two Frequency-based Electronic Apex Locators
    Jung, Il-Young
    Yoon, Bum-Hee
    Lee, Shin-Jae
    Lee, Seung Jong
    JOURNAL OF ENDODONTICS, 2011, 37 (01) : 49 - 52
  • [3] In vivo comparison of the accuracy of two electronic apex locators
    Silveira, Luiz F. M.
    Petry, Fernanda V.
    Martos, Josue
    Neto, Joao B. C.
    AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (02) : 70 - 72
  • [4] A comparison between two electronic apex locators:: an in vivo investigation
    Venturi, M
    Breschi, L
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (01) : 36 - 45
  • [5] In vivo comparison of working length determination with two electronic apex locators
    Wrbas, K. T.
    Ziegler, A. A.
    Altenburger, M. J.
    Schirrmeister, J. F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (02) : 133 - 138
  • [6] A comparison between two electronic apex locators:: an ex vivo investigation
    Venturi, M.
    Breschi, L.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (05) : 362 - 373
  • [7] An ex vivo comparison of three electronic apex locators
    Baginska, Joanna
    Linczuk, Ewa
    Botulinski, Bartlomiej
    Kierklo, Anna
    HEALTHMED, 2012, 6 (10): : 3275 - 3280
  • [8] Ex vivo comparison of two electronic apex locators with different scales and frequencies
    Hör, D
    Krusy, S
    Attin, T
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (12) : 855 - 859
  • [9] An in vivo comparison of five different electronic apex locators
    Al-Shaher, Abdulaziz A.
    Madi, Samar
    ENDO-ENDODONTIC PRACTICE TODAY, 2011, 5 (01): : 17 - 25
  • [10] Comparison of two electronic apex locators on human cadavers
    Luca Marigo
    Gian Luca Gervasi
    Francesco Somma
    Giuseppe Squeo
    Raffaella Castagnola
    Clinical Oral Investigations, 2016, 20 : 1547 - 1550