An in vivo comparison of two frequency-based electronic apex locators

被引:69
|
作者
Welk, AR [1 ]
Baumgartner, JC [1 ]
Marshall, JG [1 ]
机构
[1] Oregon Hlth Sci Univ, Sch Dent, Dept Endodontol, Portland, OR 97201 USA
关键词
D O I
10.1097/00004770-200308000-00002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare the accuracy of a two-frequency (Root ZX) and a five-frequency (Endo Analyzer Model 8005) electronic apex locator under clinical conditions. Thirty-two teeth planned for extraction were used. The coronal portion of each canal was flared using Gates Glidden drills and Orifice Shapers. The canals were irrigated with 2.6% sodium hypochlorite. A K-type file was used to determine a separate working length in each canal using the electronic apex locators. The teeth were extracted and the apical 4 mm of each root canal was exposed along the long axis of the tooth. Photographic slides of each canal were projected and the file position in relation to the minor diameter was determined by two investigators. The mean distance between the electronic apex locator working length and minor diameter was 1.03 mm for the Endo Analyzer and 0.19 mm for the Root ZX. A paired sample t test showed that the Endo Analyzer had significantly longer readings beyond the minor diameter than the Root ZX (p < 0.0001). The ability to locate the minor diameter (+/- 0.5 mm) was 90.7% for the Root ZX and 34.4% for the Endo Analyzer Model 8005.
引用
收藏
页码:497 / 500
页数:4
相关论文
共 50 条
  • [31] Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: An in vivo study
    Moscoso, Saddy
    Pineda, Kenneth
    Basilio, Juan
    Alvarado, Carlos
    Roig, Miguel
    Duran-Sindreu, Fernando
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2014, 19 (02): : E202 - E205
  • [32] Comparison of working length determination with radiographs and four electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (06) : 510 - 518
  • [33] In Vivo Evaluation of 3 Electronic Apex Locators: Root ZX Mini, Apex ID, and Propex Pixi
    Serna-Pena, Gabriela
    Gomes-Azevedo, Susana
    Flores-Trevino, Jorge
    Madla-Cruz, Elizabeth
    Rodriguez-Delgado, Idalia
    Martinez-Gonzalez, Gustavo
    JOURNAL OF ENDODONTICS, 2020, 46 (02) : 158 - 161
  • [34] Influence of different sized files on the accuracy of two electronic apex locators
    Orosco, Fernando A.
    da Silva, Guilherme F.
    Weckwerth, Paulo H.
    Lopes, Maria Thereza M.
    Garcia, Alan M. R.
    Duarte, Marco Antonio H.
    de Moraes, Ivaldo G.
    AUSTRALIAN ENDODONTIC JOURNAL, 2018, 44 (03) : 251 - 254
  • [36] An overview of electronic apex locators: part 1
    Ali, R.
    Okechukwu, N. C.
    Brunton, P.
    Nattress, B.
    BRITISH DENTAL JOURNAL, 2013, 214 (04) : 155 - 158
  • [37] THE USE OF ELECTRONIC APEX LOCATORS IN ENDODONTIC THERAPY
    FOUAD, AF
    INTERNATIONAL ENDODONTIC JOURNAL, 1993, 26 (01) : 13 - 14
  • [38] An overview of electronic apex locators: part 2
    Ali, R.
    Okechukwu, N. C.
    Brunton, P.
    Nattress, B.
    BRITISH DENTAL JOURNAL, 2013, 214 (05) : 227 - 231
  • [39] Accuracy of Three Electronic Apex Locators in Anterior and Posterior Teeth: An Ex Vivo Study
    Mancini, Manuele
    Felici, Roberto
    Conte, Gabriele
    Costantini, Marco
    Cianconi, Luigi
    JOURNAL OF ENDODONTICS, 2011, 37 (05) : 684 - 687
  • [40] An overview of electronic apex locators: part 2
    R. Ali
    N. C. Okechukwu
    P. Brunton
    B. Nattress
    British Dental Journal, 2013, 214 : 227 - 231