Comparative Accuracy and Reliability of Three Electronic Apex Locators in Determining the Apical Constriction of Molar Canals: A Micro-CT Evaluation

被引:0
|
作者
Barakat, Reem M. [1 ]
Almohareb, Rahaf A. [2 ]
Alharbi, Arwa O. [3 ]
Alhazmi, Asma [3 ]
Alomar, Reem [3 ]
机构
[1] Princess Nourah Bint Abdulrahman Univ, King Abdullah bin Abdulaziz Univ Hosp, Dent Clin Dept, POB 84428, Riyadh 11671, Saudi Arabia
[2] Princess Nourah Bint Abdulrahman Univ, Coll Dent, Dept Clin Dent Sci, POB 84428, Riyadh 11671, Saudi Arabia
[3] Princess Nourah Bint Abdulrahman Univ, Coll Dent, Dent Intern, POB 84428, Riyadh 11671, Saudi Arabia
关键词
apical constriction; electronic apex locator; micro-CT imaging; root canal treatment; working length; WORKING LENGTH DETERMINATION; ENDODONTIC TREATMENT; COMPUTED TOMOGRAPHY; PRECISION;
D O I
10.3390/jcm13175199
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Determining the correct apical limit for root canal treatment is essential for its success. This study evaluates the accuracy of three electronic apex locators (EALs) in locating the apical constriction (AC) in molar canals. Methods: Forty extracted human mandibular molars were scanned using micro-CT, and endodontic access cavities were created. Teeth were mounted in alginate, and three EALs-Root ZX-mini, Root ZX-II, and Sirona integrated apex locator-were used to measure the canal working length in dry canals and with EDTA gel. Micro-CT scans were performed with files in place, and the distance from the AC was calculated. Measurements within 0.1-0.5 mm were categorized as 'close'. Those extending beyond towards the major foramen were categorized as 'beyond', otherwise they were classified as 'far'. Data analysis was conducted with a level of significance set at 5%. Results: Most readings for all EALs were in the 'close' category, with significant differences between devices (p < 0.0001). Root ZX-mini and Root ZX-II had 74.4% and 72.5% 'close' readings, respectively, versus 51% for Sirona integrated. Accuracy did not differ significantly between dry and EDTA-treated canals (p = 0.306). All EALs demonstrated excellent operator reliability (ICC 0.996-1.00). Conclusions: All EALs accurately determined AC, unaffected by lubricants. However, Root ZX-mini and Root ZX-II outperformed Sirona integrated. All EALs showed consistent reliability.
引用
收藏
页数:12
相关论文
共 30 条
  • [1] Evaluation of the accuracy of nine electronic apex locators by using Micro-CT
    Connert, T.
    Judenhofer, M. S.
    Huelber-J, M.
    Schell, S.
    Mannheim, J. G.
    Pichler, B. J.
    Loest, C.
    ElAyouti, A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (02) : 223 - 232
  • [2] In vitro evaluation of the accuracy of three electronic apex locators
    Lucena-Martín, C
    Robles-Gijón, V
    Ferrer-Luque, M
    de Mondelo, JMNR
    JOURNAL OF ENDODONTICS, 2004, 30 (04) : 231 - 233
  • [3] A Micro-computed Tomographic Evaluation of the Accuracy of 3 Electronic Apex Locators in Curved Canals of Mandibular Molars
    Piasecki, Lucila
    dos Reis, Paulo Jose
    Jussiani, Eduardo Inocente
    Andrello, Avacir Casanova
    JOURNAL OF ENDODONTICS, 2018, 44 (12) : 1872 - 1877
  • [4] Evaluation of the electronic apical locators accuracy in determining the work length.
    Brochado, VHD
    Neto, UXD
    Goncalves, JF
    Ramos, CAS
    Bramante, CM
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B101 - B101
  • [5] Evaluation of the accuracy of three electronic apex locators using glass tubules
    Fan, W
    Fan, B
    Gutmann, JL
    Bian, Z
    Fan, MW
    INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (02) : 127 - 135
  • [6] Evaluation of the accuracy of three eletronic apex locators in determining canal measurement.
    Costa, FLM
    Bolan, M
    Felippe, MCS
    Felippe, WT
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 154 - 154
  • [7] Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study
    Milanovic, Ivana
    Ivanovic, Vladimir
    Vujaskovic, Mirjana
    Ignjatovic, Snezana
    Miletic, Vesna
    AUSTRALIAN ENDODONTIC JOURNAL, 2015, 41 (01) : 35 - 43
  • [8] Micro-CT Study of the In Vivo Accuracy of a Wireless Electronic Apex Locator
    De -Deus, Gustavo
    Cozer, Viviany
    Souza, Erick Miranda
    Silva, Emmanuel Joao Nogueira Leal
    Wigler, Ronald
    Belladonna, Felipe Goncalves
    Simoes-Carvalho, Marco
    Versiani, Marco Aurelio
    JOURNAL OF ENDODONTICS, 2022, 48 (09) : 1152 - 1160
  • [9] Ex Vivo Evaluation of the Accuracy of Electronic Foramen Locators in Root Canals with an Obstructed Apical Foramen
    de Vasconcelos, Bruno Carvalho
    Verissimo Chaves, Rebeca Dibe
    Vivacqua-Gomes, Nilton
    de Miranda Candeiro, George Taccio
    Bernardes, Ricardo Affonso
    Vivan, Rodrigi Ricci
    Hungaro Duarte, Marco Antonio
    JOURNAL OF ENDODONTICS, 2015, 41 (09) : 1551 - 1554
  • [10] A laboratory study of the accuracy of three electronic apex locators: influence of embedding media and radiographic assessment of the electronic apical limit
    Iparraguirre Nunovero, M. F.
    Piasecki, L.
    Segato, A. V. K.
    Westphalen, V. P. D.
    Silva Neto, U. X.
    Carneiro, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2021, 54 (07) : 1200 - 1206