Comparative Accuracy and Reliability of Three Electronic Apex Locators in Determining the Apical Constriction of Molar Canals: A Micro-CT Evaluation

被引:0
|
作者
Barakat, Reem M. [1 ]
Almohareb, Rahaf A. [2 ]
Alharbi, Arwa O. [3 ]
Alhazmi, Asma [3 ]
Alomar, Reem [3 ]
机构
[1] Princess Nourah Bint Abdulrahman Univ, King Abdullah bin Abdulaziz Univ Hosp, Dent Clin Dept, POB 84428, Riyadh 11671, Saudi Arabia
[2] Princess Nourah Bint Abdulrahman Univ, Coll Dent, Dept Clin Dent Sci, POB 84428, Riyadh 11671, Saudi Arabia
[3] Princess Nourah Bint Abdulrahman Univ, Coll Dent, Dent Intern, POB 84428, Riyadh 11671, Saudi Arabia
关键词
apical constriction; electronic apex locator; micro-CT imaging; root canal treatment; working length; WORKING LENGTH DETERMINATION; ENDODONTIC TREATMENT; COMPUTED TOMOGRAPHY; PRECISION;
D O I
10.3390/jcm13175199
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Determining the correct apical limit for root canal treatment is essential for its success. This study evaluates the accuracy of three electronic apex locators (EALs) in locating the apical constriction (AC) in molar canals. Methods: Forty extracted human mandibular molars were scanned using micro-CT, and endodontic access cavities were created. Teeth were mounted in alginate, and three EALs-Root ZX-mini, Root ZX-II, and Sirona integrated apex locator-were used to measure the canal working length in dry canals and with EDTA gel. Micro-CT scans were performed with files in place, and the distance from the AC was calculated. Measurements within 0.1-0.5 mm were categorized as 'close'. Those extending beyond towards the major foramen were categorized as 'beyond', otherwise they were classified as 'far'. Data analysis was conducted with a level of significance set at 5%. Results: Most readings for all EALs were in the 'close' category, with significant differences between devices (p < 0.0001). Root ZX-mini and Root ZX-II had 74.4% and 72.5% 'close' readings, respectively, versus 51% for Sirona integrated. Accuracy did not differ significantly between dry and EDTA-treated canals (p = 0.306). All EALs demonstrated excellent operator reliability (ICC 0.996-1.00). Conclusions: All EALs accurately determined AC, unaffected by lubricants. However, Root ZX-mini and Root ZX-II outperformed Sirona integrated. All EALs showed consistent reliability.
引用
收藏
页数:12
相关论文
共 30 条
  • [21] Micro-CT evaluation of rotary and reciprocating glide path and shaping systems outcomes in maxillary molar curved canals
    Mario Alovisi
    Damiano Pasqualini
    Nicola Scotti
    Giorgia Carpegna
    Allegra Comba
    Mattia Bernardi
    Fabio Tutino
    Mario Dioguardi
    Elio Berutti
    Odontology, 2022, 110 : 54 - 61
  • [22] Ex vivo evaluation of the accuracy and coefficient of repeatability of three electronic apex locators using a simple mounting model: a preliminary report
    D'Assuncao, F. L. C.
    Albuquerque, D. S.
    Salazar-Silva, J. R.
    Dos Santos, V. C.
    Sousa, J. C. N.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (04) : 269 - 274
  • [23] Morphologic Classification of Root Canals and Incidence of Accessory Canals in Maxillary First Molar Palatal Roots: Three-Dimensional Observation and Measurements using Micro-CT
    Matsunaga, Satoru
    Shimoo, Yoshiaki
    Kinoshita, Hideaki
    Yamada, Masashi
    Usami, Akinobu
    Tamatsu, Yuichi
    Abe, Shinichi
    JOURNAL OF HARD TISSUE BIOLOGY, 2014, 23 (03) : 329 - 333
  • [24] Micro-CT evaluation of several glide path techniques and ProTaper Next shaping outcomes in maxillary first molar curved canals
    Alovisi, M.
    Cemenasco, A.
    Mancini, L.
    Paolino, D.
    Scotti, N.
    Bianchi, C. C.
    Pasqualini, D.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (04) : 387 - 397
  • [25] Evaluation of three obturation techniques in the apical third of mandibular first molar mesial root canals using micro-computed tomography
    Oh, Soram
    Perinpanayagam, Hiran
    Kum, Daniel J. W.
    Lim, Sang-Min
    Yoo, Yeon-Jee
    Chang, Seok Woo
    Lee, Woocheol
    Baek, Seung-Ho
    Zhu, Qiang
    Kum, Kee Yeon
    JOURNAL OF DENTAL SCIENCES, 2016, 11 (01) : 95 - 102
  • [26] Positive and negative pressure irrigation in oval root canals with apical ramifications: a computational fluid dynamics evaluation in micro-CT scanned real teeth
    Lorono, G.
    Zaldivar, J. R.
    Arias, A.
    Cisneros, R.
    Dorado, S.
    Jimenez-Octavio, J. R.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (05) : 671 - 679
  • [27] Comparative evaluation of the accuracy of electronic apex locators and cone-beam computed tomography in detection of root canal perforation and working length during endodontic retreatment
    Koc, Simay
    Harorli, Hatice
    Kustarci, Alper
    BMC ORAL HEALTH, 2024, 24 (01):
  • [28] Comparative Evaluation of Three Access Cavity Preparation Techniques on Root Canal Instrumentation Using Micro-CT: An In Vitro Study
    Khare, Mrunmayee, V
    Sivarajan, Ranjith Kumar
    Venkatesh, Vijay
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [29] Comparative Evaluation of Cutting Efficiency, Cyclic Fatigue, Corrosion Resistance, and Autoclave Cycle Effects of Three Different File Systems: An In-vitro Micro-CT and Metallurgy Analysis
    Venkatesh, Kondas V.
    Varghese, Eldho J.
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2022, 14 (06): : 551 - 560
  • [30] Comparative Micro-CT Evaluation of Dentinal Tubule Penetration of BIO-C and AH Plus Jet Root Canal Sealer Using Three Intra-Canal Activation Techniques
    Vivek, K.
    Sreedhar, Sreeja
    Nair, Siddharth V.
    Sreelekshmi, V.
    Jitha, J.
    Viswanadhan, Anitha
    Athira, P. M.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 5) : S4568 - S4571