The Use of Micro-Computed Tomography to Determine the Accuracy of 2 Electronic Apex Locators and Anatomic Variations Affecting Their Precision

被引:32
|
作者
Piasecki, Lucila [1 ,2 ]
Carneiro, Everdan [3 ]
da Silva Neto, Ulisses Xavier [3 ]
Ditzel Westphalen, Vania Portela [3 ]
Brandao, Christian Giampietro [4 ]
Gambarini, Gianluca [2 ]
Azim, Adham A. [1 ]
机构
[1] Univ Buffalo, Sch Dent Med, Dept Periodont & Endodont, Buffalo, NY USA
[2] Sapienza Univ, Dept Endodont, Rome, Italy
[3] Pontif Catholic Univ Parana, Dept Endodont, Curitiba, Parana, Brazil
[4] State Univ West Parana, Dept Endodont, Cascavel, Parana, Brazil
关键词
Apex ID; apical limit; electronic apex locator; micro-computed tomographic imaging; Root ZX; working length; ROOT ZX II; IN-VIVO; APICAL FORAMEN; EX-VIVO; VITRO; REPEATABILITY; CONSTRICTION; OBTURATION; LOCATION; MOLARS;
D O I
10.1016/j.joen.2016.04.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to compare the accuracy of 2 electronic apex locators (EALs), Apex ID (SybronEndo, Glendora, CA) and Root ZX (J. Morita, Tokyo, Japan), by means of micro computed tomographic (micro-CT) imaging and to determine anatomic variations that may affect their accuracy. Methods: The root canal length (RCL) and working length (WL) of 33 single-rooted premolars were measured using a visual method, 3-dimensional micro-CT reconstructions, and 2 different EALs. Two different measurements were recorded for each EAL: at the "APEX/0.0" mark and at the "0.5" mark. The WL was determined using 2 different methods: method 1: at the "0.5 mark" of the apex locator and method 2: subtracting 0.5 mm from the "APEX/0.0" mark. The precision of measurements was compared with those recorded by micro-CT imaging. Apical foramen (AF) position and diameter, apical constriction (AC) diameter, distance between the AC and the AF, and the presence/absence of accessory canals were recorded from the micro-CT scans, and their correlation to the accuracy of EALs was determined. Results: There was no statistically significant difference in the RCL measurements by any of the different methods. There was a statistically significant difference in the WL recorded by micro-CT imaging compared with those by the visual method and at the "APEX/0.0 mark" - 0.5 mm (P = .031). There was no difference in the measurements acquired by any of the EALs. The "APEX/0.0 mark" - 0.5 mm was less accurate than the "0.5" mark. However, the results were not statistically significant (P > .05). The position of the AF and the AC AF distance affected the accuracy of the RCL (P = .003) and the "0.5" mark (P = .013). Conclusions: Root ZX and Apex ID are equally precise in determining the RCL and WL. The "0.5" mark can be used to determine the WL with high precision. Some anatomic variations may influence the accuracy of EALs.
引用
收藏
页码:1263 / 1267
页数:5
相关论文
共 13 条
  • [1] The use of micro-computed tomography to determine the accuracy of electronic working length with two apex locators
    Suguro, Hisashi
    Nishihara, Anna
    Tamura, Takahito
    Nakamura, Takeshi
    Toyama, Yurika
    Takeichi, Osamu
    JOURNAL OF ORAL SCIENCE, 2021, 63 (02) : 167 - 169
  • [2] Clinical Accuracy and Precision of 3 Multifrequency Electronic Apex Locators Assessed through Micro-Computed Tomographic Imaging
    De-Deus, Gustavo
    Cozer, Viviany
    Souza, Erick Miranda
    Silva, Emmanuel Joao Nogueira Leal
    Belladonna, Felipe Goncalves
    Simoes-Carvalho, Marco
    Versiani, Marco Aurelio
    JOURNAL OF ENDODONTICS, 2023, 49 (05) : 487 - 495
  • [3] Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed Tomography Study
    Cinar, Firdevs
    Ustun, Yakup
    EUROPEAN ENDODONTIC JOURNAL, 2020, 5 (03): : 226 - 230
  • [4] A Micro-computed Tomographic Evaluation of the Accuracy of 3 Electronic Apex Locators in Curved Canals of Mandibular Molars
    Piasecki, Lucila
    dos Reis, Paulo Jose
    Jussiani, Eduardo Inocente
    Andrello, Avacir Casanova
    JOURNAL OF ENDODONTICS, 2018, 44 (12) : 1872 - 1877
  • [5] Evaluation of the accuracy of electronic apex locators, cone-beam computed tomography, and radiovisiography in primary teeth: An in vitro study
    Kayabasi, Mevlut
    Oznurhan, Fatih
    MICROSCOPY RESEARCH AND TECHNIQUE, 2020, 83 (11) : 1330 - 1335
  • [6] The use of micro-computed tomography to determine the fabric cross-sectional area and stress
    Zhu, Licheng
    Naebe, Maryam
    JOURNAL OF THE TEXTILE INSTITUTE, 2019, 110 (10) : 1459 - 1467
  • [7] Accuracy and Precision of Iodine Quantification in Subtracted Micro-Computed Tomography: Effect of Reconstruction and Noise Removal Algorithms
    Ayala-Dominguez, Lizbeth
    Medina, Luis-Alberto
    Aceves, Carmen
    Lizano, Marcela
    Brandan, Maria-Ester
    MOLECULAR IMAGING AND BIOLOGY, 2023, 25 (06) : 1084 - 1093
  • [8] Accuracy and Precision of Iodine Quantification in Subtracted Micro-Computed Tomography: Effect of Reconstruction and Noise Removal Algorithms
    Lízbeth Ayala-Dominguez
    Luis-Alberto Medina
    Carmen Aceves
    Marcela Lizano
    Maria-Ester Brandan
    Molecular Imaging and Biology, 2023, 25 : 1084 - 1093
  • [9] An Evaluation of the Accuracy and Precision of Ceramic Orthodontic Bracket Slot Dimensions Utilizing Micro-Computed Tomography (Micro-CT)
    Garrett, Antonio
    Alghilan, Maryam A.
    Ash, Simon
    Awawdeh, Mohammed
    Singh, Parmjit
    TOMOGRAPHY, 2023, 9 (04) : 1369 - 1380
  • [10] In Vitro Comparison of the Accuracy of Cone-Beam Computed Tomography Scanning and Electronic Apex Locators in Detection of Simulated Root Perforations in Different Localizations
    Harorli, Hatice
    Koc, Simay
    Kustarci, Alper
    JOURNAL OF ENDODONTICS, 2023, 49 (12) : 1676 - 1681