Improved solar milk chilling system using variable refrigerant flow technology (VRF)

被引:13
|
作者
Khan, Khawar Saeed [1 ]
Amjad, Waseem [2 ]
Munir, Anjum [2 ]
Hensel, Oliver [1 ]
机构
[1] Univ Kassel, Dept Agr & Blosyst Engn, Kassel, Germany
[2] Univ Agr Faisalabad, Dept Energy Syst Engn, Faisalabad, Pakistan
关键词
Solar energy; Variable refrigerant flow technology; Decentralized milk chilling; Torque load minimizing; PERFORMANCE;
D O I
10.1016/j.solener.2020.01.014
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The improper post milking handling and storage results in a complete wastage due to the microorganisms and bacterial multiplication present in raw milk. The torque load minimalizing in the chilling unit using a solar photovoltaic (PV) is indeed a challenging task for the smooth functioning of the milk chilling system especially for the conventional (reciprocating) type of compressors. The variable refrigerant flow (VRF) technology not only solves the toque load problem but also reduces the size of peak power requirement of PV array. The present study enables the design of an improved solar chilling system consists of a chilling tank (200 L capacity) coupled with one tonne of refrigeration unit powered by PV panels (2 kWp) and employing VRF technology to make system more energy efficient by reducing the torque load. Experiments were conducted using different batch sizes (50, 100, 150 and 200 L) to decrease the raw milk temperature from 30 degrees C to 4 degrees C. During optimization phase the comparative power required to run various types of compressors (reciprocating, rotary with capacitor and rotary with VRF) were found to be 1.8 kW, 1.2 kW and 0.8 kW, respectively whereas the torque loads were noted to be 3.3 kW, 1.6 kW and zero kW for respective compressor type. The experimental and modeled predicted power consumption and chilling time under different batch sizes revealed excellent correlation coefficient (R-2 = 0.99, P < 0.0001). Around one tonne of refrigeration unit is sufficient to chill 200 L of milk up to 4 degrees C within less than two hours.
引用
收藏
页码:317 / 325
页数:9
相关论文
共 50 条
  • [21] Efficiency and adaptability: a study on variable refrigerant flow (VRF) air conditioning systems in Sri Lanka
    Senarathna, D. S. N.
    Waidyasekara, K. G. A. S.
    Vidana, S. S. C. G.
    PROPERTY MANAGEMENT, 2024, 42 (04) : 580 - 597
  • [22] A comprehensive review of variable refrigerant flow (VRF) and ventilation designs for thermal comfort in commercial buildings
    Yau, Yat Huang
    Rajput, Umair Ahmed
    Badarudin, Ahmad
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (05) : 1935 - 1961
  • [24] Optimal insulation's thickness of pipes in Variable Refrigerant Flow (VRF) system—An-Najah Child Institute as a case study
    Abujab, Mohammed
    Abusafa, Abdelrahim
    Energy Reports, 2022, 8 : 321 - 330
  • [25] Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system during the heating-defrosting cyclic operation
    Enteria, Napoleon
    Yamaguchi, Hideki
    Miyata, Masato
    Sawachi, Takao
    Kuwasawa, Yasuo
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 12 (02):
  • [26] Optimal insulation's thickness of pipes in Variable Refrigerant Flow (VRF) system-An-Najah Child Institute as a case study
    Abujab, Mohammed
    Abusafa, Abdelrahim
    ENERGY REPORTS, 2022, 8 : 321 - 330
  • [27] Experimental evaluation and simulation of a variable refrigerant- flow (VRF) air-conditioning system with outdoor air processing unit
    Park, Doo Yong
    Yun, Gyeong
    Kim, Kang Soo
    ENERGY AND BUILDINGS, 2017, 146 : 122 - 140
  • [28] Variable Refrigerant Flow: Demonstration of Efficient Space Conditioning Technology Using Variable Speed Drives
    Amarnath, K. R.
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 1052 - 1061
  • [29] Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial loadings at different outdoor air temperatures
    Enteria, Napoleon
    Yamaguchi, Hideki
    Miyata, Masato
    Sawachi, Takao
    Kuwasawa, Yasuo
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 11 (02):
  • [30] Energy diagnosis of variable refrigerant flow (VRF) systems: Data mining technique and statistical quality control approach
    Liu, Jiangyan
    Liu, Jiahui
    Chen, Huanxin
    Yuan, Yue
    Li, Zhengfei
    Huang, Ronggeng
    ENERGY AND BUILDINGS, 2018, 175 : 148 - 162