Experimental evaluation and simulation of a variable refrigerant- flow (VRF) air-conditioning system with outdoor air processing unit

被引:34
|
作者
Park, Doo Yong [1 ]
Yun, Gyeong [1 ]
Kim, Kang Soo [1 ]
机构
[1] Korea Univ, Dept Architecture, 5-1 Anam Dong, Seoul 136713, South Korea
关键词
Variable refrigerant flow heat pump; Field performance measurement; EnergyPlus; Validation; Dedicated outdoor air system; Thermal comfort; PUMP DESICCANT SYSTEMS; ENERGY SIMULATION; COOLING CONDITIONS; VENTILATION; SEASON; INTEGRATION; MODE;
D O I
10.1016/j.enbuild.2017.04.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Variable refrigerant flow (VRF) refers to the ability of an air-conditioning (AC) system to control the amount of refrigerant flowing to the multiple evaporators (indoor units). This study compares the actual energy use of a building, equipped with a VRF system with simulation results obtained using EnergyPlus. Also, the aim of this study is to analyze the performance related to energy and thermal comfort when the VRF system without ventilation is replaced with the VRF system with the energy recovery ventilation (ERV) or VRF system with the dedicated outside air system (DOAS). The measured power use of the VRF system is very similar to the simulated power use of the VRF system. The mean value of the difference between simulation and measured data in monthly power use in summer and winter was 3.3% and 3.6%, respectively. The yearly energy use of the VRF system without ventilation is found to be 213.6 kWh/m(2) a. The VRF system with ERV in case 4 and the VRF system with DOAS in case 8 are found to be 16.8% and 26.0% higher than the VRF system without ventilation, respectively. Through the entire year, it was found that 17.2% of indoor air condition data provided by the VRF system without ventilation in the winter and 16.2% of the data in the summer fall within the ASHRAE winter and summer comfort zones. In order to improve the thermal comfort, the setpoint temperature in winter needs to be increased and the humidity in summer needs to be reduced. On the other hand, it was found that 93.9% of indoor air condition data provided by the VRF system with DOAS in the winter and 83.8% of the data in the summer fall within the ASHRAE winter and summer comfort zones. When the VRF system without ventilation is replaced with the VRF system with DOAS, the thermal comfort percentage is improved during the winter and summer by 76.7% and 67.6%, respectively. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 140
页数:19
相关论文
共 50 条
  • [1] Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial loadings at different outdoor air temperatures
    Enteria, Napoleon
    Yamaguchi, Hideki
    Miyata, Masato
    Sawachi, Takao
    Kuwasawa, Yasuo
    [J]. JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 11 (02):
  • [2] Control and energy simulation of variable refrigerant flow air conditioning system combined with outdoor air processing unit
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fang, Xing
    Fan, Bo
    [J]. APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) : 385 - 395
  • [3] Simulation of variable refrigerant flow air conditioning system in heating mode combined with outdoor air processing unit
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fan, Bo
    Fang, Xing
    [J]. ENERGY AND BUILDINGS, 2014, 68 : 571 - 579
  • [4] A refrigerant charge fault detection method for variable refrigerant flow (VRF) air-conditioning systems
    Liu, Jiangyan
    Hu, Yunpeng
    Chen, Huanxin
    Wang, Jiangyu
    Li, Guannan
    Hu, Wenju
    [J]. APPLIED THERMAL ENGINEERING, 2016, 107 : 284 - 293
  • [5] Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial and unbalanced thermal loadings
    Enteria, Napoleon
    Yamaguchi, Hideki
    Miyata, Masato
    Sawachi, Takao
    Kuwasawa, Yasou
    [J]. JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 11 (01):
  • [6] Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system during the heating-defrosting cyclic operation
    Enteria, Napoleon
    Yamaguchi, Hideki
    Miyata, Masato
    Sawachi, Takao
    Kuwasawa, Yasuo
    [J]. JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 12 (02):
  • [7] EXERGY ANALYSIS OF THE PERFORMANCE OF A VARIABLE REFRIGERANT FLOW (VRF) AIR CONDITIONING SYSTEM
    Padilla, Miguel
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2011, 19 (01) : 57 - 68
  • [8] Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions
    Zhou, Y. P.
    Wu, J. Y.
    Wang, R. Z.
    Shiochi, S.
    [J]. ENERGY AND BUILDINGS, 2007, 39 (02) : 212 - 220
  • [9] Simulation and experimental validation of the variable-refrigerant-volume (VRV) air-conditioning system in EnergyPlus
    Zhou, Y. P.
    Wu, J. Y.
    Wang, R. Z.
    Shiochi, S.
    Li, Y. M.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (06) : 1041 - 1047
  • [10] Coordinated optimization of the variable refrigerant flow and variable air volume combined air-conditioning system in heating conditions
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    He, Chao
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 904 - 916