Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial loadings at different outdoor air temperatures

被引:2
|
作者
Enteria, Napoleon [1 ]
Yamaguchi, Hideki [2 ]
Miyata, Masato [2 ]
Sawachi, Takao [2 ]
Kuwasawa, Yasuo [1 ]
机构
[1] Bldg Res Inst, 1 Tachihara, Tsukuba, Ibaraki 3050802, Japan
[2] Natl Inst Land & Infrastruct Management, 1 Tachihara, Tsukuba, Ibaraki 3050802, Japan
来源
关键词
Air-conditioning system; Variable refrigerant flow; Thermal loading; Energy consumption;
D O I
10.1299/jtst.2016jtst0029
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper shows the performance evaluation of the variable refrigerant flow (VRF) air-conditioning system at different outdoor air temperatures during cooling and heating operations. The purpose of this study is to determine the real performance of the system when operating at different outdoor temperatures. The one outdoor unit's and two indoor units' VRF system was used as a test specimen in the controlled testing chambers in which temperature and humidity were controlled. Several test cases were done covering from partial to full thermal loadings for the different outdoor air temperatures. The results showed that the outdoor air temperature much affected the performance of the VRF air-conditioning system. It showed that during the cooling operation, as the outdoor air dry bulb temperature increases, the coefficient of the performance ratio decreases. In the heating operation, as the outdoor air dry bulb with corresponding wet bulb temperature decreases, the coefficient of the performance ratio decreases. The defrosting mode, which occurs during the heating operation, affects the indoor chamber's temperature as the air temperature becomes very low due to the indoor units having become an evaporator. The results of the study showed the importance of the VRF air-conditioning system performances at different outdoor air dry bulb and wet bulb temperatures. Hence, it is important to consider the outdoor air temperatures when calculating the energy consumption of the VRF air-conditioning system to be installed in new and/or retrofitted buildings as they affect the electric energy consumption.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial and unbalanced thermal loadings
    Enteria, Napoleon
    Yamaguchi, Hideki
    Miyata, Masato
    Sawachi, Takao
    Kuwasawa, Yasou
    [J]. JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 11 (01):
  • [2] Experimental evaluation and simulation of a variable refrigerant- flow (VRF) air-conditioning system with outdoor air processing unit
    Park, Doo Yong
    Yun, Gyeong
    Kim, Kang Soo
    [J]. ENERGY AND BUILDINGS, 2017, 146 : 122 - 140
  • [3] Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system during the heating-defrosting cyclic operation
    Enteria, Napoleon
    Yamaguchi, Hideki
    Miyata, Masato
    Sawachi, Takao
    Kuwasawa, Yasuo
    [J]. JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 12 (02):
  • [4] EXERGY ANALYSIS OF THE PERFORMANCE OF A VARIABLE REFRIGERANT FLOW (VRF) AIR CONDITIONING SYSTEM
    Padilla, Miguel
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2011, 19 (01) : 57 - 68
  • [5] A refrigerant charge fault detection method for variable refrigerant flow (VRF) air-conditioning systems
    Liu, Jiangyan
    Hu, Yunpeng
    Chen, Huanxin
    Wang, Jiangyu
    Li, Guannan
    Hu, Wenju
    [J]. APPLIED THERMAL ENGINEERING, 2016, 107 : 284 - 293
  • [6] Exergoenvironmental Evaluation of the Desiccant Air-Conditioning System Subjected to Different Regeneration Temperatures
    Enteria, Napoleon
    Yoshino, Hiroshi
    Sataki, Akira
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (04)
  • [7] Coordinated optimization of the variable refrigerant flow and variable air volume combined air-conditioning system in heating conditions
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    He, Chao
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 904 - 916
  • [8] The performance of an air-conditioning system with the refrigerating circle using air as refrigerant
    Chen, Y
    Xie, GZ
    Wu, YZ
    [J]. 2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 499 - 505
  • [9] Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions
    Zhou, Y. P.
    Wu, J. Y.
    Wang, R. Z.
    Shiochi, S.
    [J]. ENERGY AND BUILDINGS, 2007, 39 (02) : 212 - 220
  • [10] Energy Studies on Central and Variable Refrigerant Flow Air-Conditioning Systems
    Abdullah, H.
    Nitamakwuavan, S.
    Jalaludin, A. F.
    [J]. 4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 486 - 490