Improved solar milk chilling system using variable refrigerant flow technology (VRF)

被引:13
|
作者
Khan, Khawar Saeed [1 ]
Amjad, Waseem [2 ]
Munir, Anjum [2 ]
Hensel, Oliver [1 ]
机构
[1] Univ Kassel, Dept Agr & Blosyst Engn, Kassel, Germany
[2] Univ Agr Faisalabad, Dept Energy Syst Engn, Faisalabad, Pakistan
关键词
Solar energy; Variable refrigerant flow technology; Decentralized milk chilling; Torque load minimizing; PERFORMANCE;
D O I
10.1016/j.solener.2020.01.014
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The improper post milking handling and storage results in a complete wastage due to the microorganisms and bacterial multiplication present in raw milk. The torque load minimalizing in the chilling unit using a solar photovoltaic (PV) is indeed a challenging task for the smooth functioning of the milk chilling system especially for the conventional (reciprocating) type of compressors. The variable refrigerant flow (VRF) technology not only solves the toque load problem but also reduces the size of peak power requirement of PV array. The present study enables the design of an improved solar chilling system consists of a chilling tank (200 L capacity) coupled with one tonne of refrigeration unit powered by PV panels (2 kWp) and employing VRF technology to make system more energy efficient by reducing the torque load. Experiments were conducted using different batch sizes (50, 100, 150 and 200 L) to decrease the raw milk temperature from 30 degrees C to 4 degrees C. During optimization phase the comparative power required to run various types of compressors (reciprocating, rotary with capacitor and rotary with VRF) were found to be 1.8 kW, 1.2 kW and 0.8 kW, respectively whereas the torque loads were noted to be 3.3 kW, 1.6 kW and zero kW for respective compressor type. The experimental and modeled predicted power consumption and chilling time under different batch sizes revealed excellent correlation coefficient (R-2 = 0.99, P < 0.0001). Around one tonne of refrigeration unit is sufficient to chill 200 L of milk up to 4 degrees C within less than two hours.
引用
收藏
页码:317 / 325
页数:9
相关论文
共 50 条
  • [41] Variable refrigerant flow air conditioning system applicant company selection using PROMETHEE method
    Abaci, Nejla
    Ic, Yusuf Tansel
    INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2022, 13 (04) : 1177 - 1204
  • [42] Variable refrigerant flow air conditioning system applicant company selection using PROMETHEE method
    Nejla Abacı
    Yusuf Tansel İç
    International Journal of Energy and Environmental Engineering, 2022, 13 : 1177 - 1204
  • [43] Comparison between the chiller air cooled with the variable refrigerant flow technology for high building air conditioning system
    Arifin, Z.
    Wahyu, W.
    5TH ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2020), 2021, 1098
  • [44] Performance comparison between bypass cycle and injection cycle for sub-cooling methods in multi-split variable refrigerant flow (VRF) system in hot seasons
    Min, Byungchae
    Jang, Seokhoon
    Lee, Taemin
    Bae, Heunghee
    Moon, Cheoreon
    Choi, Gyungmin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 107 : 202 - 213
  • [45] Promoting variable refrigerant flow system with a simple design and analysis tool
    Zhai, Zhiqiang
    Rivas, Jessica
    JOURNAL OF BUILDING ENGINEERING, 2018, 15 : 218 - 228
  • [46] A review of variable refrigerant flow HVAC system components for residential application
    Hernandez, Andrew C., III
    Fumo, Nelson
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 110 : 47 - 57
  • [47] Research on Cooperative Control and Stability of Variable Refrigerant Flow Refrigeration System
    Cheng, Zheming
    Zhang, Jiani
    Tao, Leren
    Chen, Jianhong
    Zheng, Zhigao
    Huang, Lihao
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2025, 17 (01)
  • [48] Field test of multi-functional variable refrigerant flow system
    Lin, Xiaojie
    Lee, Hoseong
    Hwang, Yunho
    Radermacher, Reinhard
    Oh, Saikee
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (05) : 648 - 657
  • [49] Development and validation of a new variable refrigerant flow system model in EnergyPlus
    Hong, Tianzhen
    Sun, Kaiyu
    Zhang, Rongpeng
    Hinokuma, Ryohei
    Kasahara, Shinichi
    Yura, Yoshinori
    ENERGY AND BUILDINGS, 2016, 117 : 399 - 411
  • [50] A machine learning bayesian network for refrigerant charge faults of variable refrigerant flow air conditioning system
    Hu, Min
    Chen, Huanxin
    Shen, Limei
    Li, Guannan
    Guo, Yabin
    Li, Haorong
    Li, Jiong
    Hu, Wenju
    ENERGY AND BUILDINGS, 2018, 158 : 668 - 676