Performance evaluation of a new small-volume coagulation monitor - The SmartCheck INR system

被引:4
|
作者
Gardiner, Chris [1 ]
Longair, Ian [1 ]
Hills, Jennifer [1 ]
Cohen, Hannah [1 ]
Mackie, Ian J. [2 ]
Machin, Samuel J. [1 ]
机构
[1] UCL Hosp, Dept Haematol, London W1T 4EU, England
[2] UCL, London, England
关键词
coagulation; anticoagulation; point of care; international normalized ratio;
D O I
10.1309/K87FWL7UA8H8ANHR
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The SmartCheck INR (Unipath, Bedford, England) is a point-of-care device for professional and patient self-monitoring of oral anticoagulant therapy. It measures the international normalized ratio (INR) and assesses test strip integrity, temperature, and sample quality. No significant differences were found in SmartCheck INR results from 3 different instruments or in 3 test-strip lots. Within run imprecision was 0.89% and 6.36% for low and high control samples, respectively (mean INR, 0.99 and 4.08, respectively). Comparability was assessed in 68 patients receiving warfarin by using PTHS Plus (Instrumentation Laboratory, Lexington, MA) and Innovin (Dade Behring, Marburg, Germany) thromboplastins. Good correlations were observed between the methods (r = 0.89 and r = 0.90, respectively) with no significant differences in means: SmartCheck INR, 2.82; Innovin, 2.75; PTHS Plus, 2.74. Clinical agreement with laboratory methods was 88% for Innovin and 97% for PTHS Plus. The SmartCheck INR was easy to use with no mechanical failures during the evaluation and a low test-strip failure rate of 4.7%. The SmartCheck INR provides accurate and reproducible results and is suitable for routine monitoring of oral anticoagulant therapy in the majority of patients.
引用
收藏
页码:500 / 504
页数:5
相关论文
共 50 条
  • [41] Performance evaluation of the new CoaguChek XS system compared with the established CoaguChek system by patients experienced in INR-self management
    Braun, Siegmund
    Watzke, Herbert
    Hasenkam, J. Michael
    Schwab, Michael
    Wolf, Tanja
    Dovifat, Clemens
    Voeller, Heinz
    THROMBOSIS AND HAEMOSTASIS, 2007, 97 (02) : 310 - 314
  • [42] Performance Evaluation of an Imaging Radiation Portal Monitor System
    Vasiljevic, Jana
    Cederwall, Bo
    APPLIED SCIENCES-BASEL, 2022, 12 (18):
  • [43] Evaluation of a short-incubation-time small-volume radiocarbon-uptake algal toxicity test
    vanderHeever, JA
    Grobbelaar, JU
    JOURNAL OF APPLIED PHYCOLOGY, 1996, 8 (01) : 65 - 71
  • [44] EVALUATION OF MORTALITY IN LARGE- VS SMALL-VOLUME FLUID ADMINISTRATION IN PATIENTS WITH SEPSIS AND SEPTIC SHOCK
    Shah, Virali
    Borthelle, Marcos
    Heraud, Sebastian Ocrospoma
    Gogolauri, Saba
    Gutierrez, Victor Antonio Perez
    Adderley, Natalia
    Farukhuddin, Fnu
    Keftassa, Emnet
    Fraga, Sebastian Gandarillas
    Miller, Dwayvania
    Singh, Inderpreet
    Padilla, Joane
    Teferici, Stela
    Menon, Vidya P.
    CHEST, 2022, 162 (04) : 984A - 985A
  • [45] Performance evaluation of the microINR® point-of-care INR-testing system
    Joubert, J.
    van Zyl, M. C.
    Raubenheimer, J.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (02) : 115 - 122
  • [46] A small-volume multiplexed pumping system for automated, high-frequency water chemistry measurements in volume-limited applications
    Maxwell, Bryan M.
    Birgand, Francois
    Smith, Brad
    Aveni-Deforge, Kyle
    HYDROLOGY AND EARTH SYSTEM SCIENCES, 2018, 22 (11) : 5615 - 5628
  • [47] Subaqueous eruption and shallow-water reworking of a small-volume Surtseyan edifice at Kakanui, New Zealand
    Corcoran, P. L.
    Moore, L. N.
    CANADIAN JOURNAL OF EARTH SCIENCES, 2008, 45 (12) : 1469 - 1485
  • [48] Bioavailability of vitamin B12 using a small-volume nebulizer ophthalmic drug delivery system
    Kahn, M
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (04): : 402 - 407
  • [49] Resistivity measurement of a small-volume sample using two planar disc electrodes and a new geometric factor
    Tan, Yoke-Lin
    Chong, Chee-Earn
    IEEE SENSORS JOURNAL, 2008, 8 (5-6) : 516 - 521
  • [50] New approach to the evaluation of the coagulation system functional state
    Korshunov, GV
    Korshunov, AG
    Puchinyan, DM
    Nassonova, GV
    Yaroshevskaya, SI
    THROMBOSIS AND HAEMOSTASIS, 1997, : 780 - 781