Performance evaluation of a new small-volume coagulation monitor - The SmartCheck INR system

被引:4
|
作者
Gardiner, Chris [1 ]
Longair, Ian [1 ]
Hills, Jennifer [1 ]
Cohen, Hannah [1 ]
Mackie, Ian J. [2 ]
Machin, Samuel J. [1 ]
机构
[1] UCL Hosp, Dept Haematol, London W1T 4EU, England
[2] UCL, London, England
关键词
coagulation; anticoagulation; point of care; international normalized ratio;
D O I
10.1309/K87FWL7UA8H8ANHR
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The SmartCheck INR (Unipath, Bedford, England) is a point-of-care device for professional and patient self-monitoring of oral anticoagulant therapy. It measures the international normalized ratio (INR) and assesses test strip integrity, temperature, and sample quality. No significant differences were found in SmartCheck INR results from 3 different instruments or in 3 test-strip lots. Within run imprecision was 0.89% and 6.36% for low and high control samples, respectively (mean INR, 0.99 and 4.08, respectively). Comparability was assessed in 68 patients receiving warfarin by using PTHS Plus (Instrumentation Laboratory, Lexington, MA) and Innovin (Dade Behring, Marburg, Germany) thromboplastins. Good correlations were observed between the methods (r = 0.89 and r = 0.90, respectively) with no significant differences in means: SmartCheck INR, 2.82; Innovin, 2.75; PTHS Plus, 2.74. Clinical agreement with laboratory methods was 88% for Innovin and 97% for PTHS Plus. The SmartCheck INR was easy to use with no mechanical failures during the evaluation and a low test-strip failure rate of 4.7%. The SmartCheck INR provides accurate and reproducible results and is suitable for routine monitoring of oral anticoagulant therapy in the majority of patients.
引用
收藏
页码:500 / 504
页数:5
相关论文
共 50 条
  • [31] Small-volume electrochemical detection of trace nucleic acids using a vibrating electrode system
    Wang, J
    Sahlin, E
    Paz, JLL
    ELECTROANALYSIS, 1999, 11 (05) : 380 - 383
  • [32] Conceptualisation of a novel electromechanical system for small-volume needle-free jet injection
    Mohizin, Abdul
    Kim, Jung Kyung
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2023, 17 (01)
  • [33] Evaluation of a novel integrated quality control system for a patient self testing INR monitor.
    Goodman, DE
    Blunt, J
    Hewett, G
    CLINICAL CHEMISTRY, 2004, 50 (06) : A184 - A184
  • [34] New Small-Volume High-Precision TMR Busbar DC Current Sensor
    Xu, X. P.
    Liu, T. Z.
    Zhu, M.
    Wang, J. G.
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (02)
  • [35] Needle-free small-volume Liquid Injection System Powered by a Rotary Actuator
    Zhang, Aoyu
    Hogan, N. Catherine
    Hunter, Ian W.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 292 - 295
  • [36] Sensitivity analysis of a small-volume objective heat stability evaluation test for recombined concentrated milk
    Kasinos, Marios
    Karbakhsh, Rafat R.
    Van der Meeren, Paul
    INTERNATIONAL JOURNAL OF DAIRY TECHNOLOGY, 2015, 68 (01) : 38 - 43
  • [37] EVALUATION OF THE INFLUENCE OF OPEN AND CLOSED-AMPOULE TECHNOLOGIES ON PARTICULATE MATTER IN SMALL-VOLUME PARENTERALS
    BERNUZZI, M
    RAGGI, P
    MONTANARI, L
    PREGNOLATO, F
    PAVANETTO, F
    JOURNAL OF PARENTERAL SCIENCE AND TECHNOLOGY, 1993, 47 (05): : 265 - 269
  • [38] ANOMALOUS PROPERTIES OF A SIMPLE SMALL-VOLUME MEMBRANE-TRANSPORT SYSTEM AT STEADY-STATE
    HILL, TL
    CHEN, Y
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1985, 82 (11) : 3654 - 3657
  • [39] Small-volume refractive index and fluorescence sensor for micro total analytical system (μ-TAS) applications
    Zourob, M
    Mohr, S
    Fielden, PR
    Goddard, NJ
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 94 (03): : 304 - 312
  • [40] MICROBATCH CRYSTALLIZATION UNDER OIL - A NEW TECHNIQUE ALLOWING MANY SMALL-VOLUME CRYSTALLIZATION TRIALS
    CHAYEN, NE
    STEWART, PDS
    BLOW, DM
    JOURNAL OF CRYSTAL GROWTH, 1992, 122 (1-4) : 176 - 180