Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure

被引:249
|
作者
Wilke, Hans-Joachim [1 ]
Drumm, J. [2 ]
Haeussler, K. [1 ]
Mack, C. [1 ]
Steudel, W. -I. [2 ]
Kettler, A. [1 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech Director L Claes, D-89081 Ulm, Germany
[2] Saarland Univ Hosp, Dept Neurosurg, Homburg, Germany
关键词
lumbar spine; interspinous implant; biomechanics; flexibility; intradiscal pressure;
D O I
10.1007/s00586-008-0657-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Interspinous implants are used to treat lumbar spinal stenosis or facet joint arthritis. The aims of implanting interspinous devices are to unload the facet joints, restore foraminal height and provide stability especially in extension but still allow motion. The aim of this in vitro study was to compare four different interspinous implants-Colfex, Wallis, Diam and X-Stop-in terms of their three-dimensional flexibility and the intradiscal pressure. Twenty-four human lumbar spine specimens were divided into four equal groups and tested with pure moments in flexion/extension, lateral bending and axial rotation: (1) intact, (2) defect, (3) after implantation. Range of motion and the intradiscal pressure were determined.In each implant-group the defect caused an increase in range of motion by about 8% in lateral bending to 18% in axial rotation. Implantation had similar effects with all four implants. In extension, Coflex, Wallis, Diam, and X-Stop all overcompensated the instability caused by the defect and allowed about 50% of the range of motion of the intact state. In contrast, in flexion, lateral bending and axial rotation the values of the range of motion stayed about the values of the defect state. Similarly the intradiscal pressure after implantation was similar to that of the intact specimens in flexion, lateral bending and axial rotation but much smaller during extension. All tested interspinous implants had a similar effect on the flexibility: they strongly stabilized and reduced the intradiscal pressure in extension, but had almost no effect in flexion, lateral bending and axial rotation.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 50 条
  • [31] Effect of new nucleus pulposus replacement on the flexibility motion and intradiscal pressure at the adjacent level
    Yao, Nü-Zhao
    Wang, Wen-Jun
    Jin, Da-Di
    Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 2011, 26 (01): : 81 - 86
  • [32] Effect of an interspinous implant on loads in the lumbar spine
    Rohlmann, A
    Zander, T
    Burra, NK
    Bergmann, G
    BIOMEDIZINISCHE TECHNIK, 2005, 50 (10): : 343 - 347
  • [33] Biomechanical analysis of lumbar spine with interbody fusion surgery and U-shaped lumbar interspinous spacers
    Yin, Jia-Yu
    Guo, Li-Xin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (07) : 788 - 798
  • [34] Biomechanical efficacy of a combined interspinous fusion system with a lumbar interbody fusion cage
    Kim, Yeong-Hyeon
    Jung, Tae-Gon
    Park, Eun-Young
    Kang, Guen-Woo
    Kim, Kyung-Ah
    Lee, Sung-Jae
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (05) : 997 - 1001
  • [35] Anatomy of Lumbar Interspinous Ligaments: Attachment, Thickness, Fibre Orientation and Biomechanical Importance
    Mahato, Niladri Kumar
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2013, 31 (01): : 351 - 355
  • [36] Intradiscal Pressure Distributions in Degenerated Intervertebral Discs: A Biomechanical Investigation
    Rezaei, Asghar
    Cheng, Chih-Hsiu
    Schreiber, Areonna
    Dashtdar, Babak
    Potes, Maria Astudillo
    Liu, Xifeng
    An, Kai-Nan
    Kaufman, Kenton
    Lu, Lichun
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2025, 45 (01) : 55 - 62
  • [37] Biomechanical efficacy of a combined interspinous fusion system with a lumbar interbody fusion cage
    Yeong-Hyeon Kim
    Tae-Gon Jung
    Eun-Young Park
    Guen-Woo Kang
    Kyung-Ah Kim
    Sung-Jae Lee
    International Journal of Precision Engineering and Manufacturing, 2015, 16 : 997 - 1001
  • [38] Acute biomechanical and histological effects of intradiscal electrothermal therapy on human lumbar discs
    Kleinstueck, FS
    Diederich, CJ
    Nau, WH
    Puttlitz, CM
    Smith, JA
    Bradford, DS
    Lotz, JC
    SPINE, 2001, 26 (20) : 2198 - 2207
  • [39] Properties of an interspinous fixation device (ISD) in lumbar fusion constructs: a biomechanical study
    Techy, Fernando
    Mageswaran, Prasath
    Colbrunn, Robb W.
    Bonner, Tara F.
    McLain, Robert F.
    SPINE JOURNAL, 2013, 13 (05): : 572 - 579
  • [40] Biomechanical effect of vibration on the fused lumbar spine with different stabilizers
    Fan, Wei
    Zhang, Chi
    Zhan, Dan
    Guo, Li-Xin
    BIOINSPIRED BIOMIMETIC AND NANOBIOMATERIALS, 2023, 12 (01) : 24 - 28